JW030A-M Lineage Power, JW030A-M Datasheet

no-image

JW030A-M

Manufacturer Part Number
JW030A-M
Description
CONVERTER DC/DC 5V 30W OUT
Manufacturer
Lineage Power
Series
JW030r
Type
Isolated with Remote On/Offr
Datasheet

Specifications of JW030A-M

Output
5V
Number Of Outputs
1
Power (watts)
30W
Mounting Type
Through Hole
Voltage - Input
36 ~ 75V
Package / Case
9-DIP Module
1st Output
5 VDC @ 6A
Size / Dimension
2.40" L x 2.28" W x 0.50" H (61mm x 57.9mm x 12.7mm)
Power (watts) - Rated
30W
Operating Temperature
-40°C ~ 100°C
Efficiency
81%
Approvals
CE, CSA, UL, VDE
Lead Free Status / RoHS Status
Contains lead / RoHS non-compliant
3rd Output
-
2nd Output
-
4th Output
-
Lead Free Status / Rohs Status
No

Available stocks

Company
Part Number
Manufacturer
Quantity
Price
Part Number:
JW030A-M
Manufacturer:
LUCENT
Quantity:
27
Part Number:
JW030A-M
Manufacturer:
ASTEC
Quantity:
300
Part Number:
JW030A-M
Manufacturer:
TYCO
Quantity:
20 000
Data Sheet
March 26, 2008
Options
n
n
n
n
Description
The JW030-Series Power Modules are dc-dc converters that operate over an input voltage range of 36 Vdc to
75 Vdc and provide precisely regulated outputs. The outputs are isolated from the inputs, allowing versatile
polarity configurations and grounding connections. The modules have maximum power ratings of up to 30 W at
a typical full-load efficiency of up to 83%.
These power modules feature remote on/off, output sense (both negative and positive leads), and output volt-
age adjustment, which allows output voltage adjustment from 80% to 110% for the JW030A-M, D-M, F-M, G-M
and 60% to 110% for the JW030B-M, C-M of the nominal output voltage. For disk-drive applications, the
JW030B-M Power Module provides a motor-start surge current of 3 A. The modules are PC board-mountable
and encapsulated in metal cases. The modules are rated to full load at 100 °C case temperature. No external
filtering is required.
* UL is a registered trademark of Underwriters Laboratories, Inc.
† CSA is a registered trademark of Canadian Standards Association.
‡ This product is intended for integration into end-use equipment. All the required procedures for CE marking of end-use equipment should
The JW030-Series Power Modules use advanced, surface-
mount technology and deliver high-quality, compact,
dc-dc conversion at an economical price.
be followed. (The CE mark is placed on selected products.)
Heat sinks available for extended operation
Choice of remote on/off logic configuration
Short pins: 2.79 mm ± 0.25 mm
Short pins: 3.68 mm ± 0.25 mm
(0.110 in. ± 0.010 in.)
(0.145 in. ± 0.010 in.)
Features
n
n
n
n
n
n
n
n
n
n
n
n
n
n
n
n
Applications
n
n
JW030-Series Power Modules:
36 Vdc to 75 Vdc Inputs; 30 W
Small size: 61.0 mm x 57.9 mm x 12.7 mm
Low output noise
Constant frequency
Industry-standard pinout
Metal case
Case ground pin
2:1 input voltage range
High efficiency: 83% typical
Overcurrent protection
Remote on/off
Remote sense
Adjustable output voltage: 80% to 110% of V
Output overvoltage protection
UL* 1950 Recognized, CSA
Certified, VDE 0805 (EN60950, IEC950) Licensed
CE mark meets 73/23/EEC and 93/68/EEC
directives
Within FCC Class A radiated limits
Distributed power architectures
Communications equipment
(2.40 in. x 2.28 in. x 0.50 in.)
C22.2 No. 950-95
O, nom

Related parts for JW030A-M

JW030A-M Summary of contents

Page 1

... These power modules feature remote on/off, output sense (both negative and positive leads), and output volt- age adjustment, which allows output voltage adjustment from 80% to 110% for the JW030A-M, D-M, F-M, G-M and 60% to 110% for the JW030B-M, C-M of the nominal output voltage. For disk-drive applications, the JW030B-M Power Module provides a motor-start surge current The modules are PC board-mountable and encapsulated in metal cases. The modules are rated to full load at 100 ° ...

Page 2

... Min V — – –40 stg — — — — Symbol Min Typ — — I, max — — I — — — 50 March 26, 2008 Max Unit 80 Vdc 100 °C 110 °C 500 Vdc 1500 V Max Unit 75 Vdc 1 0 — mAp-p — dB Lineage Power ...

Page 3

... B-M, C-M A-M, D-M, F-M, G-M B-M, C-M JW030D-M, F-M, G-M JW030A-M JW030B-M JW030B-M JW030C-M JW030D-M, F-M, G-M JW030A-M JW030B-M JW030C-M JW030D-M, F-M, G-M JW030A-M JW030B-M JW030C-M JW030D-M JW030G-M JW030F-M JW030A-M JW030B-M, C-M All 36 Vdc to 75 Vdc Inputs Symbol Min Typ ...

Page 4

... Isolation Resistance General Specifications Parameter Calculated MTBF ( max Weight 4 4 (continued) Device Code or Code Suffix JW030D-M, F-M, G-M JW030A-M, B-M, C-M All JW030D-M, F-M, G-M JW030A-M, B-M, C-M All Min — 10 Min ; °C) C — March 26,2008 Symbol Min Typ Max — ...

Page 5

... Lineage Power Device Code or Code Suffix All All All All All ; All All All D-M, G-M, F-M, A-M B-M, C-M JW030D-M JW030G-M JW030F-M JW030A-M JW030B-M JW030C-M 36 Vdc to 75 Vdc Inputs Symbol Min Typ Max I — — 1.0 on/off V –0.7 — 1.2 ...

Page 6

... Variation over Ambient Temperature Range 6 2.5 2.0 1.5 1.0 0 Figure 3. JW030D-M Typical Output (V) I 8-740(C) 3.0 2.5 2.0 1.5 1.0 0.5 0 100 Figure 4. JW030G-M Typical Output 8-852(C).a Data Sheet March 26, 2008 OUTPUT CURRENT, I (A) O Characteristics OUTPUT CURRENT, I (A) O Characteristics Lineage Power 8 9 8-1331( 8-2557(C) ...

Page 7

... 1.5 1.0 0 OUTPUT CURRENT, I Figure 5. JW030F-M Typical Output Characteristics OUTPUT CURRENT, I Figure 6. JW030A-M Typical Output Characteristics Lineage Power 0.0 0.5 1.0 1 Figure 7. JW030B-M Typical Output (A) O 8-1194( 0.0 0.5 1.0 1 (A) O Figure 8. JW030C-M Typical Output 8-737(C) JW030-Series Power Modules: 36 Vdc to 75 Vdc Inputs ...

Page 8

... OUTPUT CURRENT, I Figure 10. JW030G-M Typical Converter Efficiency vs. Output Current Figure 11. JW030F-M Typical Converter Efficiency 4.0 4.5 5.0 5.5 6.0 6.5 (A) O 8-1330( Figure 12. JW030A-M Typical Converter Efficiency 4.6 5.6 6.6 (A) O 8-2558(C) Data Sheet March 26, 2008 OUTPUT CURRENT, I (A) O vs. Output Current ...

Page 9

... O 8-743(C) Figure 16. JW030A-M, B-M, C-M Typical Output Voltage for a Step Load Change from 50% to 75% JW030-Series Power Modules: 36 Vdc to 75 Vdc Inputs Δ A/10 µs Δt 500 µs TIME, t (500 µs/div) 8-731(C).a Δ A/10 µs Δ ...

Page 10

... Voltage for a Step Load Change from 50% to 25% 102 100 Δ A/10 µs Δt 25 TIME, t (500 µs/div) Figure 18. JW030A-M, B-M, C-M Typical Output Voltage for a Step Load Change from 50% to 25% 10 100 500 µs Figure 19. Typical Output Voltage Start-Up when 8-732(C).a Signal Applied to Remote On/Off 500 µ ...

Page 11

... V (+) V (– – Figure 22. Output Voltage and Efficiency Measurement Test Setup Lineage Power Design Considerations Grounding Considerations CURRENT The case is not connected internally allowing the user PROBE flexibility in grounding. V (+) I Input Source Impedance V (-) I The power module should be connected to a low ac- impedance input source ...

Page 12

... Lineage Power36 Vdc to 75 Vdc Inputs Feature Descriptions Overcurrent Protection To provide protection in a fault (output overload) condi- tion, the unit is equipped with internal current-limiting circuitry and can endure current limiting for an unlim- ited duration. At the point of current-limit inception, the unit shifts from voltage control to current control. If the ...

Page 13

... With an external resistor connected between the TRIM and SENSE(+) pins (R ), the output voltage set adj-up point (V ) increases (see Figure 26). The following O, adj equations determine the required external-resistor value to obtain an output voltage change of %ý. JW030A-M, B-M, C-M: ⎞ %Δ V ⎛ ⎛ ⎞ 10 kΩ O, nom ...

Page 14

... MEASURE CASE TEMPERATURE ( CENTER OF UNIT AIRFLOW 76.2 (3.00) 101.6 (4.00) 203.2 (8.00) Figure 27. Thermal Test Setup March 26, 2008 12.7 (0.50) WIND TUNNEL WALL AIR- FLOW 203.2 (8.00) AIR VELOCITY AND AMBIENT TEMPERATURE MEASURED BELOW THE MODULE 19.1 (0.75) Lineage Power 8-1046(C) ...

Page 15

... With the known power dissipation and a given local ambient temperature, the appropriate air- flow can be chosen from the derating curves in Figure 34. For example, if the JW030A-M dissipates 6.2 W, the minimum airflow °C environment (200 ft./min.). 8 ...

Page 16

... Figure 35 shows the case-to-ambient thermal resis- tance, θ (°C/W), for these modules. These curves can be used to predict which heat sink will be needed for a particular environment. For example, if the JW030A-M dissipates heat °C environment with an airflow of 0.7 ms sink required can be determined as follows: where: 1 ...

Page 17

... AIR VELOCITY, ms Figure 35. Case-to-Ambient Thermal Resistance vs. Air Velocity Curves; Either Orientation Lineage Power Although the previous example uses 100 °C as the (continued) maximum case temperature, for extremely high reliabil- ity applications, one can use a lower temperature for max ...

Page 18

... Side View 12.7 (0.50) MAX Bottom View 5.1 (0.20) 50.8 (2.00) 35.56 (1.400) 18 57.9 (2.28) MAX V (+) I ON/ 61.0 OFF JW030A-M (2.40) MAX DC-DC Power Module CASE 36-75V 0.95A OUT MADE IN USA M3 V (-) I 0.51 (0.020) 5.1 (0.20) MIN 7.1 (0.28) STANDOFF, 4 PLACES 12 ...

Page 19

... M3 x 0.5 CLEARANCE HOLE, 4 PLACES (OPTIONAL) Device Comcode Code JW030D1-M 107670259 JW030G1-M 108448259 JW030F1-M 107587859 JW030A1-M 107587776 JW030B1-M 107587818 JW030C1-M 107587834 JW030D-M 107587842 JW030G-M TBD JW030F-M 107600546 JW030A-M 107584278 JW030B-M 107587800 JW030C-M 107587826 8-716(C) 19 ...

Page 20

... Lineage Power reserves the right to m ake changes to the produc t(s) or inform ation contained herein without notice. No liability is ass res ult of their use or applic ation. No rights under any patent acc om pany the sale of any oduct information. ...