VHB75-D24-S24 CUI Inc, VHB75-D24-S24 Datasheet - Page 4

CONVERTER DC/DC 24V OUT 75W

VHB75-D24-S24

Manufacturer Part Number
VHB75-D24-S24
Description
CONVERTER DC/DC 24V OUT 75W
Manufacturer
CUI Inc
Series
V-Infinity VHB75r
Type
Isolatedr
Datasheet

Specifications of VHB75-D24-S24

Output
24V
Number Of Outputs
1
Power (watts)
75W
Mounting Type
Through Hole
Voltage - Input
18 ~ 36V
Package / Case
9-DIP Module
1st Output
24 VDC @ 3.13A
Size / Dimension
2.40" L x 2.28" W x 0.50" H (61mm x 57.9mm x 12.7mm)
Power (watts) - Rated
75W
Operating Temperature
-40°C ~ 100°C
Efficiency
86%
Approvals
cUL, TUV, UL
Lead Free Status / RoHS Status
Lead free / RoHS Compliant
3rd Output
-
2nd Output
-
4th Output
-
Other names
102-1263
PART NUMBER: VHB75
2. OUTPUT TRIMMING (OPTIONAL)
The output voltages are preset to nominal values as indicated by the models table at the factory. If desired, the output voltage may
optionally be trimmed to a different value (+/- 10%) with external resistors and/or potentiometer as shown below.
To trim the output voltage with fixed resistors, the output voltage can be calculated as follows.
module (VHB75-Q48-S5) by 8% to 5.4V, R
Table 1. For example, to trim-up the output voltage of 5.0V
Table 1
Where: R
nominal output voltage. V
R
R
1
trim-up
and R
20050 SW 112
FIGURE 3: TRIM-UP VOLTAGE SETUP
trim-up
FIGURE 2. TRIMMING WITH
EXTERNAL POTENTIOMETER
R
The value of R
2
trim-up
are internal to the unit and are defined in
+Vin
-Vin
=
is the external resistor in K Ω . V
V - V
o
2.5V
3.3V
12V
15V
24V
5V
R1 - R2 x (V - V
=
o, nom = 5.4 - 5.0 = 0.4 V
th
Trim-Up
5.8 - 8.25 x 0.4
as follows:
R1 = 5.8 KΩ
R2 = 8.25 KΩ
Ave. Tualatin, Oregon 97062
o
trim-up
V - V
is the desired output voltage.
0.4
o
Trim
+Vo
-Vo
+S
19.656
25.474
42.215
-S
3.168
2.877
5.8
is defined as:
o, nom
o
Ω
= 6.25 (KΩ)
o, nom
13.304
16.923
trim-up
14.76
8.25
8.25
7.2
R trim-up
Ω
is calculated
o,nom
+Vin
-Vin
)
(KΩ)
is the
R load
phone
phone 503.612.2300 fax
Trim
+Vo
DESCRIPTION: dc-dc converter
-Vo
+S
-S
module (VHB75-Q48-S5) by 8% to 4.6V, R
Where: R
Table 2. For example, to trim-up the output voltage of 5.0V
Table 2
R
nominal output voltage. V
trim-down
R
1
andR
FIGURE 4: TRIM-DOWN VOLTAGE SETUP
trim-down
10KΩ
Trimpot
R
The value of R
trim-down
2
are internal to the unit and are defined in
+Vin
-Vin
fax 503.612.2382
V
=
is the external resistor in K Ω . V
o, nom
2.5V
3.3V
12V
15V
24V
5V
=
Trim-Down
R load
R1 - R2 x (V
- V
R1 = 5.8 KΩ
R2 = 10.57 KΩ
as follows:
5.8 - 10.57 x 0.4
o
trim-down
o
= 5.0 - 4.6 = 0.4 V
Trim
is the desired output voltage.
V
+Vo
-Vo
0.4
o, nom
+S
-S
86.45
2.923
6.18
150
430
5.8
is defined as:
Ω
o, nom
= 3.93 (KΩ)
- V
trim-down
rev.
page
date
10.57
10.57
60.1
130
15
94
o
R trim-down
Ω
- V )
05/2009
is calculated
o,nom
4 of 6
o
(KΩ)
is the
R load

Related parts for VHB75-D24-S24