VHB50W-Q48-S28 CUI Inc, VHB50W-Q48-S28 Datasheet - Page 6

CONVERTER DC/DC 28V 1.79A 50W

VHB50W-Q48-S28

Manufacturer Part Number
VHB50W-Q48-S28
Description
CONVERTER DC/DC 28V 1.79A 50W
Manufacturer
CUI Inc
Series
V-Infinity VHB50Wr
Type
Isolatedr
Datasheet

Specifications of VHB50W-Q48-S28

Output
28V
Number Of Outputs
1
Power (watts)
50W
Mounting Type
Through Hole
Voltage - Input
18 ~ 75V
Package / Case
9-DIP Module
1st Output
28 VDC @ 1.78A
Size / Dimension
2.40" L x 2.28" W x 0.50" H (61mm x 57.9mm x 12.7mm)
Power (watts) - Rated
50W
Operating Temperature
-40°C ~ 100°C
Efficiency
84%
Lead Free Status / RoHS Status
Lead free / RoHS Compliant
3rd Output
-
2nd Output
-
4th Output
-
Other names
102-1967
PART NUMBER: VHB50W
7. OUTPUT TRIMMING (OPTIONAL)
The output voltages are preset to nominal values as indicated by the models table at the factory. If desired, the output voltage may
optionally be trimmed to a different value (+/- 10%) with external resistors and/or potentiometer as shown below.
To trim the output voltage with fixed resistors, the output voltage can be calculated as follows.
module (VHB50W-Q48-S5) by 8% to 5.4V, R
Table 1. For example, to trim-up the output voltage of 5.0V
Table 1
Where: R
nominal output voltage. V
R
R
1
trim-up
and R
20050 SW 112
FIGURE 4: TRIM-UP VOLTAGE SETUP
trim-up
R
FIGURE 3. TRIMMING WITH
EXTERNAL POTENTIOMETER
The value of R
2
trim-up
are internal to the unit and are defined in
+Vin
-Vin
=
is the external resistor in K Ω . V
V - V
o
3.3V
12V
15V
24V
28V
48V
5V
=
R1 - R2 x (V - V
o, nom = 5.4 - 5.0 = 0.4 V
th
Trim-Up
as follows:
5.8 - 3.3 x 0.4
R1 = 5.8 KΩ
R2 = 3.3 KΩ
Ave. Tualatin, Oregon 97062
o
trim-up
V - V
is the desired output voltage.
0.4
o
Trim
+Vo
-Vo
+S
18.945
25.189
25.189
-S
3.168
608.6
74.25
5.8
is defined as:
o, nom
o
Ω
= 11.2 (KΩ)
o, nom
6.977
173.7
4.636
7.191
13.3
7.2
3.3
trim-up
R trim-up
Ω
o,nom
+Vin
-Vin
)
is calculated
(KΩ)
is the
R load
phone
phone 503.612.2300 fax
Trim
+Vo
DESCRIPTION: half-brick dc-dc converter
-Vo
+S
-S
module (VHB50W-Q48-S5) by 8% to 4.6V, R
Where: R
Table 2. For example, to trim-up the output voltage of 5.0V
Table 2
R
nominal output voltage. V
trim-down
R
1
andR
FIGURE 5: TRIM-DOWN VOLTAGE SETUP
trim-down
R
10KΩ
Trimpot
trim-down
The value of R
2
are internal to the unit and are defined in
+Vin
-Vin
fax 503.612.2382
V
=
o, nom
is the external resistor in K Ω . V
3.3V
12V
15V
24V
28V
48V
5V
=
Trim-Down
R load
R1 - R2 x (V
- V
R1 = 5.8 KΩ
R2 = 5.32 KΩ
as follows:
5.8 - 5.32 x 0.4
o
trim-down
o
= 5.0 - 4.6 = 0.4 V
Trim
is the desired output voltage.
V
+Vo
-Vo
0.4
o, nom
+S
-S
86.45
608.6
1638
6.18
150
430
5.8
is defined as:
Ω
o, nom
- V
= 9.18 (KΩ)
173.7
5.32
60.1
120
page
date
306
trim-down
15
68
o
R trim-down
Ω
- V )
06/2009
o,nom
6 of 11
o
is calculated
(KΩ)
is the
R load

Related parts for VHB50W-Q48-S28