NDY0505C Murata Power Solutions Inc, NDY0505C Datasheet - Page 2

CONV DC/DC 3W 5VIN 5VOUT DIP24

NDY0505C

Manufacturer Part Number
NDY0505C
Description
CONV DC/DC 3W 5VIN 5VOUT DIP24
Manufacturer
Murata Power Solutions Inc
Series
NDYr
Type
Isolatedr
Datasheet

Specifications of NDY0505C

Number Of Outputs
1
Output
5V
Power (watts)
3W
Mounting Type
Through Hole
Voltage - Input
4.5 ~ 9V
Package / Case
24-DIP Module (600 mil, 8 Leads)
1st Output
5 VDC @ 600mA
Size / Dimension
1.27" L x 0.58" W x 0.27" H (32.3mm x 14.7mm x 6.9mm)
Power (watts) - Rated
3W
Operating Temperature
-40°C ~ 85°C
Efficiency
66%
Approvals
UL
Output Power
1 W
Input Voltage Range
4.5 V to 9 V
Input Voltage (nominal)
5 V
Output Voltage (channel 1)
5 V
Output Current (channel 1)
250 mA
Isolation Voltage
1 KV
Package / Case Size
DIP
Output Voltage
5 V
Product
Isolated
Lead Free Status / RoHS Status
Lead free / RoHS Compliant
3rd Output
-
2nd Output
-
4th Output
-
Lead Free Status / Rohs Status
Lead free / RoHS Compliant
Other names
811-1399-5

Available stocks

Company
Part Number
Manufacturer
Quantity
Price
Part Number:
NDY0505C
Manufacturer:
EC
Quantity:
17
www.murata-ps.com
1. For lower ripple refer to circuit for reduced ripple.
OUTPUT CHARACTERISTICS
Parameter
Voltage set point accuracy
Line regulation
Load regulation
Ripple
Noise
GENERAL CHARACTERISTICS
Parameter
Switching frequency
TEMPERATURE CHARACTERISTICS
Parameter
Operation
Storage
Cooling
ISOLATION CHARACTERISTICS
Parameter
Isolation test voltage
Resistance
TECHNICAL NOTES
ISOLATION VOLTAGE
‘Hi Pot Test’, ‘Flash Tested’, ‘Withstand Voltage’, ‘Proof Voltage’, ‘Dielectric Withstand Voltage’ & ‘Isolation Test Voltage’ are all terms that relate to the same thing, a test voltage,
applied for a specifi ed time, across a component designed to provide electrical isolation, to verify the integrity of that isolation.
Murata Power Solutions NDY series of DC/DC converters are all 100% production tested at their stated isolation voltage. This is 1kVDC for 1 second.
A question commonly asked is, “What is the continuous voltage that can be applied across the part in normal operation?”
For a part holding no specifi c agency approvals, such as the NDY series, both input and output should normally be maintained within SELV limits i.e. less than 42.4V peak, or
60VDC. The isolation test voltage represents a measure of immunity to transient voltages and the part should never be used as an element of a safety isolation system. The part
could be expected to function correctly with several hundred volts offset applied continuously across the isolation barrier; but then the circuitry on both sides of the barrier must
be regarded as operating at an unsafe voltage and further isolation/insulation systems must form a barrier between these circuits and any user-accessible circuitry according to
safety standard requirements.
REPEATED HIGH-VOLTAGE ISOLATION TESTING
It is well known that repeated high-voltage isolation testing of a barrier component can actually degrade isolation capability, to a lesser or greater degree depending on materials,
construction and environment. The NDY series has an EI ferrite core, with no additional insulation between primary and secondary windings of enameled wire. While parts can be
expected to withstand several times the stated test voltage, the isolation capability does depend on the wire insulation. Any material, including this enamel (typically polyurethane)
is susceptible to eventual chemical degradation when subject to very high applied voltages thus implying that the number of tests should be strictly limited. We therefore strongly
advise against repeated high voltage isolation testing, but if it is absolutely required, that the voltage be reduced by 20% from specifi ed test voltage.
This consideration equally applies to agency recognized parts rated for better than functional isolation where the wire enamel insulation is always supplemented by a further
insulation system of physical spacing or barriers.
www.murata-ps.com
1
1
Conditions
With external input/output capacitors
Low line to high line, 3.3V output with external input/output capacitors
Low line to high line, all other outputs with external input/output capacitors
25% load to 100% load, 3.3V output with external input/output capacitors
25% load to 100% load, all other outputs with external input/output capacitors
BW = 20Hz to 300kHz, 3.3V output with external input/output capacitors
BW = 20Hz to 300kHz, all other outputs with external input/output capacitors
BW = DC to 100MHz, 3.3V output with external input/output capacitors
BW = DC to 20MHz, all other outputs with external input/output capacitors
Conditions
100% load V
25% load V
100% load V
25% load V
Conditions
Ambient temperature
Free air convection
Conditions
Flash tested for 1 second
Viso=500VDC
IN
IN
IN
IN
nominal 3.3V output
nominal, all other outputs
nominal 3.3V output
nominal, all other outputs
Technical enquiries - email: mk@murata-ps.com, tel:
Isolated 3W Wide Input DC/DC Converters
Min.
1000
Min.
Min.
Min.
160
290
290
-40
-50
80
1
Typ.
0.05
0.05
Typ.
Typ.
Typ.
0.6
0.2
±1
80
50
5
NDY Series
KDC_NDYC.E04 Page 2 of 4
Max.
0.25
Max.
Max.
Max.
120
180
100
±5
0.5
1.0
0.5
220
560
220
560
130
10
85
+44 (0)1908 615232
mV rms
mV p-p
Units
Units
Units
Units
VDC
kHz
%
%
%
%
%
ºC

Related parts for NDY0505C