NMV2412SC Murata Power Solutions Inc, NMV2412SC Datasheet - Page 2

CONV DC/DC 1W 24VIN 12VOUT SIP

NMV2412SC

Manufacturer Part Number
NMV2412SC
Description
CONV DC/DC 1W 24VIN 12VOUT SIP
Manufacturer
Murata Power Solutions Inc
Series
NMVr
Type
Isolatedr
Datasheet

Specifications of NMV2412SC

Output
±12V
Number Of Outputs
2
Power (watts)
1W
Mounting Type
Through Hole
Voltage - Input
21.6 ~ 26.4V
Package / Case
7-SIP Module (5 Leads)
1st Output
12 VDC @ 42mA
2nd Output
-12 VDC @ 42mA
Size / Dimension
0.77" L x 0.24" W x 0.39" H (19.6mm x 6.1mm x 9.9mm)
Power (watts) - Rated
1W
Operating Temperature
0°C ~ 70°C
Efficiency
80%
Approvals
UL
Dc / Dc Converter O/p Type
Fixed
No. Of Outputs
2
Input Voltage
21.6V To 26.4V
Power Rating
1W
Output Voltage
12V
Output Current
42mA
Output Voltage 2
-12V
Output Current 2
-42mA
Supply Voltage
24V
Product
Isolated
Output Power
1 W
Input Voltage Range
21.6 V to 26.4 V
Input Voltage (nominal)
24 V
Output Voltage (channel 1)
12 V
Output Current (channel 1)
42 mA
Output Voltage (channel 2)
- 12 V
Output Current (channel 2)
- 42 mA
Isolation Voltage
3 KV
Package / Case Size
SIP
Lead Free Status / RoHS Status
Lead free / RoHS Compliant
3rd Output
-
4th Output
-
Lead Free Status / Rohs Status
Lead free / RoHS Compliant
Other names
811-1611-5

Available stocks

Company
Part Number
Manufacturer
Quantity
Price
Part Number:
NMV2412SC
Manufacturer:
Murata Power Solutions Inc
Quantity:
120
Part Number:
NMV2412SC
Manufacturer:
MURATA
Quantity:
17
ABSOLUTE MAXIMUM RATINGS
Short-circuit protection
Lead temperature 1.5mm from case for 10 seconds
Input voltage V
Input voltage V
OUTPUT CHARACTERISTICS
Parameter
Rated Power
Voltage Set Point Accuracy
Line regulation
ISOLATION CHARACTERISTICS
Parameter
Isolation test voltage
Resistance
GENERAL CHARACTERISTICS
Parameter
Switching frequency
TEMPERATURE CHARACTERISTICS
Parameter
Specifi cation
Storage
Cooling
TEMPERATURE DERATING GRAPH
TECHNICAL NOTES
ISOLATION VOLTAGE
‘Hi Pot Test’, ‘Flash Tested’, ‘Withstand Voltage’, ‘Proof Voltage’, ‘Dielectric Withstand Voltage’ & ‘Isolation Test Voltage’ are all terms that relate to the same thing, a test voltage,
applied for a specifi ed time, across a component designed to provide electrical isolation, to verify the integrity of that isolation.
Murata Power Solutions NMV series of DC/DC converters are all 100% production tested at their stated isolation voltage. This is 3kVDC for 1 minute.
A question commonly asked is, “What is the continuous voltage that can be applied across the part in normal operation?”
For a part holding no specifi c agency approvals, such as the NMV series, both input and output should normally be maintained within SELV limits i.e. less than 42.4V peak, or
60VDC. The isolation test voltage represents a measure of immunity to transient voltages and the part should never be used as an element of a safety isolation system. The part
could be expected to function correctly with several hundred volts offset applied continuously across the isolation barrier; but then the circuitry on both sides of the barrier must
be regarded as operating at an unsafe voltage and further isolation/insulation systems must form a barrier between these circuits and any user-accessible circuitry according to
safety standard requirements.
REPEATED HIGH-VOLTAGE ISOLATION TESTING
It is well known that repeated high-voltage isolation testing of a barrier component can actually degrade isolation capability, to a lesser or greater degree depending on materials,
construction and environment. The NMV series has toroidal isolation transformers, with no additional insulation between primary and secondary windings of enameled wire. While
parts can be expected to withstand several times the stated test voltage, the isolation capability does depend on the wire insulation. Any material, including this enamel (typically
polyurethane) is susceptible to eventual chemical degradation when subject to very high applied voltages thus implying that the number of tests should be strictly limited. We
therefore strongly advise against repeated high voltage isolation testing, but if it is absolutely required, that the voltage be reduced by 20% from specifi ed test voltage.
This consideration equally applies to agency recognized parts rated for better than functional isolation where the wire enamel insulation is always supplemented by a further
insulation system of physical spacing or barriers.
www.murata-ps.com
1
IN
IN,
, NMV24 types
NMV48 types
1.5
1.0
0.5
2
0
0
Safe Operating
Ambient Temperature (°C)
Area
Conditions
T
See tolerance envelope
High V
Conditions
Flash tested for 1 minute
Viso= 1000VDC
Conditions
All input types
Conditions
All output types
Free air convection
50
A
=0
°C
70°C
IN
to 70
to low V
°C
100
IN
150
1 second
300°C
28V
54V
TOLERANCE ENVELOPE
3kVDC Isolated 1W Single & Dual Output DC/DC Converters
Technical enquiries email: mk@murata-ps.com, tel: +44 (0)1908 615232
+10%
+5%
V
NOM
10
NMV 24V & 48V Series
25
Output Load Current (%)
3000
Min.
Min.
Min.
Min.
-55
50
1
0
2010/11/05 KDC_NMVC2.E03 Page 2 of 4
75
Typ.
Typ.
Typ.
Typ.
100
100
+2.5%
-2.5%
-7.5%
Max.
Max.
Max.
Max.
150
1.2
70
1
Units
Units
Units
Units
%/%
VDC
kHz
°C
W