NMV0505SAC Murata Power Solutions Inc, NMV0505SAC Datasheet - Page 3

CONV DC/DC 1W 5VIN 5VOUT SIP

NMV0505SAC

Manufacturer Part Number
NMV0505SAC
Description
CONV DC/DC 1W 5VIN 5VOUT SIP
Manufacturer
Murata Power Solutions Inc
Series
NMVr
Type
Isolatedr
Datasheets

Specifications of NMV0505SAC

Number Of Outputs
1
Output
5V
Power (watts)
1W
Mounting Type
Through Hole
Voltage - Input
4.5 ~ 5.5V
Package / Case
7-SIP Module (4 Leads)
1st Output
5 VDC @ 200mA
Size / Dimension
0.77" L x 0.24" W x 0.39" H (19.6mm x 6.1mm x 9.9mm)
Power (watts) - Rated
1W
Operating Temperature
-40°C ~ 85°C
Efficiency
68%
Approvals
UL
Output Power
1 W
Input Voltage Range
4.5 V to 5.5 V
Input Voltage (nominal)
5 V
Output Voltage (channel 1)
5 V
Output Current (channel 1)
200 mA
Isolation Voltage
3 KV
Package / Case Size
SIP
Output Voltage
5 V
Product
Isolated
Lead Free Status / RoHS Status
Lead free / RoHS Compliant
3rd Output
-
2nd Output
-
4th Output
-
Lead Free Status / Rohs Status
Lead free / RoHS Compliant
Other names
811-1587-5

Available stocks

Company
Part Number
Manufacturer
Quantity
Price
Part Number:
NMV0505SAC
Manufacturer:
Murata Power Solutions Inc
Quantity:
1 814
Part Number:
NMV0505SAC
Manufacturer:
JRC
Quantity:
1 800
Part Number:
NMV0505SAC
Manufacturer:
MURATA/村田
Quantity:
20 000
Part Number:
NMV0505SAC/2
Manufacturer:
C&D
Quantity:
358
TECHNICAL NOTES
ISOLATION VOLTAGE
‘Hi Pot Test’, ‘Flash Tested’, ‘Withstand Voltage’, ‘Proof Voltage’, ‘Dielectric Withstand Voltage’ & ‘Isolation Test Voltage’ are all terms that relate to the same thing, a test voltage,
applied for a specifi ed time, across a component designed to provide electrical isolation, to verify the integrity of that isolation.
Murata Power Solutions NMV series of DC/DC converters are all 100% production tested at their stated isolation voltage. This is 3kVDC for 1 minute.
A question commonly asked is, “What is the continuous voltage that can be applied across the part in normal operation?”
For a part holding no specifi c agency approvals, such as the NMV series, both input and output should normally be maintained within SELV limits i.e. less than 42.4V peak, or
60VDC. The isolation test voltage represents a measure of immunity to transient voltages and the part should never be used as an element of a safety isolation system. The part
could be expected to function correctly with several hundred volts offset applied continuously across the isolation barrier; but then the circuitry on both sides of the barrier must
be regarded as operating at an unsafe voltage and further isolation/insulation systems must form a barrier between these circuits and any user-accessible circuitry according to
safety standard requirements.
REPEATED HIGH-VOLTAGE ISOLATION TESTING
It is well known that repeated high-voltage isolation testing of a barrier component can actually degrade isolation capability, to a lesser or greater degree depending on materials,
construction and environment. The NMV series has toroidal isolation transformers, with no additional insulation between primary and secondary windings of enameled wire. While
parts can be expected to withstand several times the stated test voltage, the isolation capability does depend on the wire insulation. Any material, including this enamel (typically
polyurethane) is susceptible to eventual chemical degradation when subject to very high applied voltages thus implying that the number of tests should be strictly limited. We
therefore strongly advise against repeated high voltage isolation testing, but if it is absolutely required, that the voltage be reduced by 20% from specifi ed test voltage.
This consideration equally applies to agency recognized parts rated for better than functional isolation where the wire enamel insulation is always supplemented by a further
insulation system of physical spacing or barriers.
CHARACTERISATION TEST METHODS
www.murata-ps.com
Ripple & Noise Characterisation Method
Ripple and noise measurements are performed with the following test confi guration.
Differential Mode Noise Test Schematic
C1
C2
C3
R1
R2
T1
RLOAD
Measured values are multiplied by 10 to obtain the specifi ed values.
SUPPLY
1uF X7R multilayer ceramic capacitor, voltage rating to be a minimum of 3 times the output voltage of the DC/DC converter
10uF tantalum capacitor, voltage rating to be a minimum of 1.5 times the output voltage of the DC/DC converter with an ESR of less
than 100mΩ at 100 kHz
100nF multilayer ceramic capacitor, general purpose
450Ω resistor, carbon fi lm, +/-1% tolerance
50Ω BNC termination
3T of the coax cable through a ferrite toroid
Resistive load to the maximum power rating of the DC/DC converter. Connections should be made via twisted wires
DC/DC Converter
Input
+
-
Output
+
-
C1 C2 C3
R LOAD
R1
3kVDC Isolated 1W Single & Dual Output DC/DC Converters
T1
NMV 5V, 12V & 15V Series
Technical enquiries - email: mk@murata-ps.com, tel:
R2
OSCILLOSCOPE
Y INPUT