HS-23-C Murata Power Solutions Inc, HS-23-C Datasheet - Page 5

no-image

HS-23-C

Manufacturer Part Number
HS-23-C
Description
HEATSINK C11
Manufacturer
Murata Power Solutions Inc
Datasheet

Specifications of HS-23-C

Accessory Type
Heat Sink Kit
Product
Heatsinks
Mounting Style
PCB
Heatsink Material
Anodized Aluminum
Dimensions
3 in L x 2 in W x 0.5 in H
Designed For
TMP, BMP and UMP DC/DC Converters
Color
Black
Lead Free Status / RoHS Status
Lead free / RoHS Compliant
For Use With/related Products
BMP & TMP Model Power Supplies
Lead Free Status / Rohs Status
Lead free / RoHS Compliant
Other names
Q4391501
Output Power
TMP Model, triple-output DC/DC converters incorporate a design tradeoff be-
tween total available output power and input voltage range. The total available
power is a function of both the nominal input voltage and the "width" of the
input voltage range. For a given nominal input (24V or 48V), narrower ranges
(2:1 vs. 4:1) have more available power. For a given "width" of input range
(2:1 or 4:1), higher nominal inputs (48V vs. 24V) have more available power.
Each device, as indicated by its part-number suffix (Q12, Q48, D24, D48),
has a total output power limitation of 25, 30, 35 or 40 Watts, respectively.
Observing these power limitations is the user's responsibility.
As indicated by its Part Number Structure, each TMP device is capable of
sourcing up to 5 Amps of +5V current as well as ±1 Amp of auxiliary (±12V
40
35
30
25
20
15
10
5
0
–40
0
Figure 5a. Temperature Derating Without Heat Sink
25
Natural Convection Cooling
150 Linear Feet Per Minute
300 Linear Feet Per Minute
30
Model Number
TMP-5/5-12/1-Q12
TMP-5/5-12/1-Q48
TMP-5/5-12/1-D24
TMP-5/5-12/1-D48
TMP-5/5-15/1-Q12
TMP-5/5-15/1-Q48
TMP-5/5-15/1-D24
TMP-5/5-15/1-D48
35
40
Ambient Temperature (°C)
45
50
Temperature Derating and Electrical Performance Curves
55
60
Voltage
10-36V
18-75V
18-36V
36-75V
10-36V
18-75V
18-36V
36-75V
Range
www.murata-ps.com
65
70
75
Table 1. Output Currents Comprising "Full Load"
Triple Output, High-Efficiency, Smaller-Package, 25-40 Watt, DC/DC Converters
80
25 Watts
30 Watts
35 Watts
40 Watts
25 Watts
30 Watts
35 Watts
40 Watts
Output
Power
85
D48 Models (40 Watts)
90
95
2.5A (12.5W)
+5V Current
2.6A (13W)
or ±15V) currents. Users have the flexibility of loading any output up to these
limits; however, you must be extremely careful not to exceed the total output
power rating of any given device. If, for example, a device with a 30W power
rating is sourcing 4A from its +5V output (representing 20W of primary output
power), that device can only supply an additional 10W from its auxiliary outputs
(±333mA from ±15V outputs or ±417mA from ±12V outputs).
As a consequence of this "power-allocation" flexibility, the definition of "full
load," as the condition under which performance specifications are tested
and listed, is ambiguous. The following table lists the primary and auxiliary
output currents that DATEL uses to define each device’s "full load."
3A (15W)
4A (20W)
4A (20W)
3A (15W)
4A (20W)
4A (20W)
Definition of "Full Load" for Specification Purposes
40
35
30
25
20
15
10
5
0
–40
0
25
Figure 5b. Temperature Derating With Heat Sink
Natural Convection Cooling
150 Linear Feet Per Minute
300 Linear Feet Per Minute
30
Technical enquiries email: sales@murata-ps.com, tel:
±12V Currents
±500mA (12W)
±625mA (15W)
±625mA (15W)
±833mA (20W)
35
40
Ambient Temperature (°C)
45
50
55
±417mA (12.5W)
±15V Currents
±500mA (15W)
±500mA (15W)
±667mA (20W)
60
MDC_TMP25-40W_B02 Page 5 of 6
TMP Models
65
70
75
80
+1 508 339 3000
85
90
95

Related parts for HS-23-C