PS12038 Powerex Inc, PS12038 Datasheet - Page 4

no-image

PS12038

Manufacturer Part Number
PS12038
Description
IC CONV AC-DC 3-PHASE 1200V 25A
Manufacturer
Powerex Inc
Datasheet

Specifications of PS12038

Voltage - Output
1200V
Number Of Outputs
1
Power (watts)
30000W
Applications
Commercial
Power Supply Type
Switching (Closed Frame)
Voltage - Input
900VAC
Mounting Type
Through Hole
1st Output
1200 VDC @ 25A
Size / Dimension
4.06" L x 3.19" W x 0.35" H (103mm x 81mm x 9mm)
Power (watts) - Rated
30000W
Operating Temperature
-20°C ~ 100°C
Lead Free Status / RoHS Status
Contains lead / RoHS non-compliant

Available stocks

Company
Part Number
Manufacturer
Quantity
Price
Part Number:
PS12038
Manufacturer:
MITSUBISHI
Quantity:
560
Part Number:
PS12038
Manufacturer:
MIT
Quantity:
20 000
Part Number:
PS12038-Y2
Manufacturer:
MITSUBISHI
Quantity:
46
Part Number:
PS12038-Y2
Manufacturer:
TOSHIBA
Quantity:
300
Part Number:
PS12038-Y2
Manufacturer:
MIT
Quantity:
20 000
106
Powerex, Inc., 200 E. Hillis Street, Youngwood, Pennsylvania 15697-1800 (724) 925-7272
PS12038
Intellimod™ Module
Application Specific IPM
25 Amperes/1200 Volts
Electrical and Mechanical Characteristics, T
Characteristics
Circuit Current (Average)
Input ON Threshold Voltage
Input OFF Threshold Voltage
Input Pull-up Resistor
PWM Input Frequency
Arm Shoot-through Blocking Time*
Input Interlock Sensing
Inverter DC-link IGBT Current
Sense Voltage Output Signal**
Inverter DC-link IGBT Current
Sense Voltage Output Limit**
Over-current Trip Level
Over-current Delay Time
Short-circuit Trip Level
Short-circuit Delay Time
Supply Circuit
Under-voltage
Protection
Fault Output Pulse Width***
Fault Output Current***
Thermistor Resistance
Material Constant****
* The dead-time has to be set externally by the CPU; it is not part of the ASIPM internal functions.
**Refer to the graph on next page.
***Fault output signalling is given only when the internal OC, SC, and UV protection circuits are activated. The OC, SC and UV protection (and fault output) operate for the lower arms only.
The OC and SC protection fault output is given in a pulse format while that of UV protection is maintained throughout the duration of the under-voltage condition.
****
Control Sector
T =
1
ln
[
R TO
R T
1
]
+
Trip Level
Reset Level
Trip Level
Reset Level
Delay Time
T O
1
V
V
UV
t
V
V
V
V
UV
I
f
I
DEAD
UV
UV
PWM
Fo(H)
R
Fo(L)
th(on)
th(off)
t
I
OC
t
t
SC
t
t
amp
amp
amp
amp
DB
OC
SC
FO
I
Ri
dV
int
D
TO
DBr
DB
Dr
D
Symbol
100%
200%
250%
0%
T
j
I
I
Input Terminal-inside Power Supply
C
C
j
= 25 C unless otherwise specified
Relates to Corresponding Inputs
= 25 C, V
Relates to Corresponding Input
= I
= I
T
j
I
OP(100%)
OP(200%)
= 25 C, V
C
T
I
Open Collector Output
C
T
C
T
= I
1
= I
T
C
Applied between
O
= 25 C, T
OP(250%)
T
= -20 C ~ 100 C
D
100 C, T
OP(0%)
C
= 25 C (298K)
T
T
= V
= T
j
j
, V
, V
D
Test Conditions
= 25 C
= 25 C
DB
= 15V, V
j
D
D
= 25 C
, V
= 15V, T
= 15V, T
2
, V
j
= 15V, V
D
= 50 C
D
125 C
= 15V
= 15V
IN
j
j
= 5V
IN
= 25 C
= 25 C
= 5V
39.0
11.0
11.5
10.1
10.6
Min.
0.8
2.5
4.0
1.5
3.0
5.0
1.0
9.5
3450
46.5
69.7
12.0
12.5
10.8
11.3
100
Typ.
1.4
3.0
2.0
4.0
1.8
50
10
50
10
10
10
2
12.75
13.25
Max.
11.6
12.1
10.5
100
2.0
4.0
2.5
5.0
50
15
15
5
1
Amperes
Amperes
Units
Volts
Volts
Volts
Volts
Volts
Volts
Volts
Volts
Volts
kHz
mA
mA
mV
mS
mA
k
k
ns
K
S
S
S
A
s

Related parts for PS12038