PFE1000F-12/T TDK Corporation, PFE1000F-12/T Datasheet - Page 3

PWR SUP AC-DC 85-265VAC 12V

PFE1000F-12/T

Manufacturer Part Number
PFE1000F-12/T
Description
PWR SUP AC-DC 85-265VAC 12V
Manufacturer
TDK Corporation
Series
PFE1000r
Datasheets

Specifications of PFE1000F-12/T

Power Supply Type
Switching (Closed Frame)
Voltage - Output
12V
Number Of Outputs
1
Power (watts)
1000W
Applications
Commercial
Voltage - Input
85 ~ 265VAC
Mounting Type
Through Hole
1st Output
12 VDC @ 60A
Size / Dimension
6.3" L x 3.94" W x 0.53" H (160mm x 100mm x 13.4mm)
Power (watts) - Rated
720W
Operating Temperature
-40°C ~ 100°C
Efficiency
82%
Approvals
CE, CSA, cUL, EN, UL
Power Supply Output Type
Fixed
No. Of Outputs
1
Output Voltage
12V
Output Current
60A
Power Rating
720W
Input Voltage
85V AC To 265V AC
Length
160mm
Width
100mm
Input Frequency
47 to 440Hz
Product Depth (mm)
100mm
Operating Temperature Min Deg. C
-40C
Lead Free Status / RoHS Status
Lead free / RoHS Compliant
Lead Free Status / RoHS Status
Lead free / RoHS Compliant, Lead free / RoHS Compliant
Other names
PFE1000F12/T
C251-01-03
BASIC CONNECTION
==NOTES==
C10
C11
C12
C13
C14
C1
C2
C3
C4
C5
C6
C7
C8
C9
F1
PFE1000F
F1
*1. Use an external fuse of fast blow type for each unit.
*2. The allowable ripple current of capacitor must be more than 3A(rms).
*3. Put this capacitor near the terminal as close as possible.
*4. The maximum capacitance that can be used is less than 2300uF(Rated capacitance).
*5. The inrush current at AC throw in can be suppressed by the external Resistor
*6. If the ambient temperature is less than -20°C, use twice the recommended capacitor above.
*7. Refer to instruction manual for further details.
*1
F25AH 250V
AC250V 1uF (Film)
470pF
470pF
AC250V 1uF (Film)
AC250V 1uF (Film)
4700pF
4700pF
AC250V 1uF (Film)
450V 1uF (Film)
450V 1uF (Film)
450V 390uF (Elec.)
450V 390uF (Elec.)
450V 390uF (Elec.)
450V 390uF (Elec.)
Avoid the connection of capacitance which is more than above, else it will lead to
module to damage.
(Built-in thermal fuse) connected between the R and +BC terminals.
C1
L1
C2
C3
C4
L2
C5
L3
C6
C7
TFR1
TFR2
C15
C16
C17
C18
C19
R1
L1
L2
L3
R1
C8
*2,3
TFR2
0.033uF
0.033uF
12V: 25V 1000uF (Elec.)
28V: 50V 470uF (Elec.)
48V: 100V 220uF (Elec.)
100V 2.2uF (Ceramic)
12V: 25V 1000uF (Elec.)
28V: 50V 470uF (Elec.)
48V: 100V 220uF (Elec.)
2mH
2mH
2mH
*5
W 470k
BASE-PLATE
AC(L)
AC(N)
Vo load/ line regulation.
Measurement point for
output ripple & noise.
(JEITA RC-9131 B probe)
Bandwidth of scope : 100MHz
Measurement point for
R
139°C (Res., Thermal fuse)
139°C (Res., Thermal fuse)
P F E1 0 0 0 F
TFR1
C9
*2,3
*5
+BC
+ ON/OFF
-ON/OFF
TRIM
COM
AUX
ENA
-BC
IOG
+V
PC
+S
-V
-S
C10
C11
C12
C13
C14
*2,3
*4
*4
*4
*4
*3
C16
C15
L= 50mm
C17 C18
*6
DENSEI-LAMBDA
C19
*6

Related parts for PFE1000F-12/T