BP5039A Rohm Semiconductor, BP5039A Datasheet

IC AC/DC CONV 24V 200MA SIP12

BP5039A

Manufacturer Part Number
BP5039A
Description
IC AC/DC CONV 24V 200MA SIP12
Manufacturer
Rohm Semiconductor
Series
BP5039r
Datasheet

Specifications of BP5039A

Voltage - Output
24V
Number Of Outputs
1
Power (watts)
4W
Applications
Commercial
Power Supply Type
Switching (Closed Frame)
Voltage - Input
100VAC
Mounting Type
Through Hole
1st Output
24 VDC @ 200mA
Size / Dimension
1.38" L x 0.36" W x 0.77" H (35mm x 9.1mm x 19.5mm)
Power (watts) - Rated
4.8W
Operating Temperature
-20°C ~ 80°C
Efficiency
82%
Input / Supply Voltage (max)
170 V
Input / Supply Voltage (min)
113 V
Operating Temperature Range
- 20 C to + 80 C
Output Current
200 mA
Lead Free Status / RoHS Status
Lead free / RoHS Compliant
www.rohm.com
©2010 ROHM Co., Ltd. All rights reserved.
Non-Isolated AC/DC Converter
100VAC Input/24VDC (200mA) Output
BP5039A
∗1 Maximum output current varies depending on ambient temperature ; please refer to derating curve.
∗2 Please refer to Load regulation, Conversion efficiency.
External Component Specifications
Input voltage range
Output voltage
Output current
Line regulation
Load regulation
Output ripple voltage
Power conversion efficiency
Output current at
Input voltage
Maximum output current
ESD endurance
Maximum surface temperature
Operating Temperature range
Storage temperature range
Absolute Maximum Ratings
Electrical Characteristics
Application Circuit
FUSE: FUSE
C1: Input capacitor
C2: Output capacitor
C3: Noise reduction
L1: Power Inductor
D1: Rectifier diode
R1: Noise reduction resistor
ZNR: Varistor
Be sure to use fuse for safety.
Vi
BP5039A
Parameter
Please verify operation and characteristics in the customer's circuit before actual usage.
Ensure that the load current does not exceed the maximum rating.
capacitor
Ii
overcurrent
Parameter
ZNR
D1
DC motor
+
C1
Symbol
R1
Io1
Io2
Vp
Vo
Vr
Vi
Io
Vl
η
12 10 7 5 3 1
FUSE
C3
Use a quick-acting fuse of (1A)
above 250V, 22 to 820µF
Ripple current 0.13Arms or above
above 25V, 100 to 470µF low impedance
ESR : 0.4Ω Max.
Ripple current 0.25Arms or above
Capacitor impedance affects the output ripple voltage.
above 250V, 0.1 to 0.22µF
Use a film or ceramic capacitor
Evaluate under actual operating conditions.
Inductance : 1.5mH Rating current : above 0.4A
In the absolute maximum ratings, the reverse surge voltage should be
400V or above the average rectifier current should be 1A or greater,
and the forward surge current should be 20A or more.
10 to 22Ω 1/4W
Determine the ideal value through actual testing.
A varistor must be used to protect against lightning surges and
static electricity.
−0.50
−0.50
Min.
113
200
150
22
70
0
Symbol
L1
Vsurge
Tc
Io
Topr
Tstg
Vcc
+
MAX
MAX
0.30
0.25
0.07
Typ.
141
245
220
24
82
C2
Io
Vo
Max.
0.50
0.50
170
200
26
−25 to +105
−20 to +80
Limits
Vp-p
Unit
170
200
105
mA
mA
mA
Pin No.
%
2
V
V
V
V
10
11
12
1
2
3
4
5
6
7
8
9
Output terminal Vo(24V)
Not used
Choke coil connect
Not used
Choke coil connect
Not used
COMMON
Not used
Not used
N.C.
Not used
Input terminal Vi(141VDC)
1/1
DC (80 to 120VAC)
Vi=141V, Io=100mA
Vi=141V
Vi=113 to 170V, Io=100mA
Vi=141V, Io=0 to 100mA
Vi=141V, Io=100mA
Vi=141V, Io=200mA
Vi=170V, Output short, Ta=25°C
Vi=170V, Output short, Ta=80°C
Function
Conditions
mApk
Unit
kV
°C
°C
°C
V
∗1
∗2
∗2
3 . 6 M A X .
Dimensions (Unit :
Derating Curve
Conversion Efficiency
Load Regulation
Surface Temperature Increase
250
200
150
100
100
50
30
25
20
15
10
40
35
30
25
20
15
10
90
80
70
60
50
40
30
20
10
0
5
0
-30
0
5
0
0
0
0
-20 -10
1
5 . 0 8
Surface Temperature Increase
Ambient Temperature Ta(°C)
50
Conversion Efficiency
50
(Ta=31°C, Vi=141V)
(Ta=25°C, Vi=141V)
(Ta=315°C, Vi=141V)
Output Current Io(mA)
50
Output Current Io(mA)
Output Current Io(mA)
3
0 . 5 ±0 . 1
0 10
Load Regulation
Data Sheet
2.54�11=27.94
Derating Curve
Operation Range
100
35.0MAX.
5
100
20
100
2010.01 - Rev.A
150
7
7 . 6 2
1 . 3 ±0 . 2
30
150
40
200
10
50
150
200
60
12
250
mm
70
200
80
300
250
)
9.1MAX.
90
4.25MAX.
0 . 2 5 ±0 . 0 5
4.85MAX.

Related parts for BP5039A

BP5039A Summary of contents

Page 1

... Power conversion efficiency η 70 Output current at Io1 200 overcurrent 150 Io2 ∗1 Maximum output current varies depending on ambient temperature ; please refer to derating curve. ∗2 Please refer to Load regulation, Conversion efficiency. Application Circuit BP5039A Be sure to use fuse for safety motor FUSE − ...

Page 2

...

Page 3

...

Page 4

No copying or reproduction of this document, in part or in whole, is permitted without the consent of ROHM Co.,Ltd. The content specified herein is subject to change for improvement without notice. The content specified herein is for the purpose ...

Related keywords