PFE500S-48 TDK Corporation, PFE500S-48 Datasheet

PWRSUP AC-DC 85-265VAC 48V 10.5A

PFE500S-48

Manufacturer Part Number
PFE500S-48
Description
PWRSUP AC-DC 85-265VAC 48V 10.5A
Manufacturer
TDK Corporation
Series
PFE500r
Type
Commercialr

Specifications of PFE500S-48

Power Supply Type
Switching (Closed Frame)
Voltage - Output
48V
Number Of Outputs
1
Power (watts)
500W
Applications
Commercial
Voltage - Input
85 ~ 265VAC
Mounting Type
Through Hole
1st Output
48 VDC @ 10.5A
Size / Dimension
4.6" L x 2.4" W x 0.5" H (116.8mm x 61mm x 12.7mm)
Power (watts) - Rated
504W
Operating Temperature
-40°C ~ 100°C
Efficiency
86%
Approvals
CE, CSA, cUL, EN, UL
Power Supply Output Type
Fixed
No. Of Outputs
1
Output Voltage
48V
Output Current
10.5A
Power Rating
504W
Input Voltage
85V AC To 265V AC
Length
116.8mm
Brand/series
PFE Series
Configuration
Encapsulated
Current, Output
10.5 A
Output
48 VDC @ 10.5 A
Power, Output
504 W
Primary Type
AC-DC
Regulation, Output
96 mA
Special Features
PFC
Voltage, Adjustment Range
38.4 - 57.6 V
Voltage, Input
85 to 265 VAC
Voltage, Output
48 VDC
Weight
250 g
Output Current (max)
10.5A
Input Frequency
47 to 63Hz
Operating Temperature Min Deg. C
-40C
Pin Count
8
Lead Free Status / RoHS Status
Lead free / RoHS Compliant
Lead Free Status / RoHS Status
Lead free / RoHS Compliant, Lead free / RoHS Compliant
Other names
285-1495
PFE500-48
PFE50048
PFE500S48

Available stocks

Company
Part Number
Manufacturer
Quantity
Price
Part Number:
PFE500S-48
Manufacturer:
PANASONIC
Quantity:
40 000
=NOTES=
*1. At 100VAC/200VAC and maximum output power.
*2. For cases where conformance to various safety specs
*3. Ratings - refer to Derating Curve on the right.
*4. Heatsink has to be chosen according to Instruction manual.
*5. External components are needed for operation.
*6. Refer to Instruction manual.
*7. Ambient Temperature min=-40°C
10 Output Voltage Range
11 Maximum Ripple & Noise
12 Maximum Line Regulation
13 Maximum Load Regulation
14 Over Current Protection
15 Over Voltage Protection
16 In-rush Current (Typ.)
17 Parallel Operation
18 Series Operation
19 Operating Temperature
20 Operating Humidity
21 Storage Temperature
22 Storage Humidity
23 Cooling
24 Withstand Voltage
25 Isolation Resistance
26 Vibration
27 Shock
28 Safety
29 Weight (Typ.)
30 Size (W x H x D)
1
2
3
4
5
6
7
8
9
(Baseplate Temperature = +25°C.)
(UL, CSA, EN) are required, input voltage range
will be 100 - 240VAC(50/60Hz).
(Refer to basic connection and instruction manual.)
C252-01-01A
ITEMS
Nominal Output Voltage
Maximum Output Current
Nominal Output Power
Efficiency (Typ.)
Input Voltage Range
Input Frequency
Input Current
Power Factor
Output Voltage Accuracy
PFE500S
(*2) (*5)
MODEL
(*1)(*5)
(*1)(*5)
(*3)(*7)
(*1)
(*1)
(*2) Hz
(*1)
(*5) mV
(*6)
(*4)
mV
mV
mm
W
%
%
%
V
A
A
A
g
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-40°C - +85°C(Baseplate)
Amplitude 0.825mm Constant (Maximum 49.0m/s
PFE500S-12
Output to Baseplate 500VDC more than 100MΩ (25°C,70%RH)
SPECIFICATIONS
5.0 / 3.0
Input-Baseplate : 2.5kVAC, Input-Output : 3.0kVAC for 1min.
82 / 83
396
120
12
33
48
48
Approved by UL60950-1,CSA60950-1,EN60950-1
61 x 12.7 x 116.8 (Refer to Outline Drawing)
At No Operating, 10-55Hz (Sweep for 1min.)
105% - 140% (Automatic recovery method)
125% - 145% (Inverter shutdown method)
Output-Baseplate : 1.5kVDC for 1min.
100
80
60
40
20
0
-40
20 - 95%RH (No Dewdrop)
10 - 95%RH (No Dewdrop)
Derating Curve
Conduction Cooled
20A / 40A peak
-40°C - +100°C
85 - 265 VAC
-20
PFE500S-28
196.1m/s
-20 / +20
0.95 min
6.2 / 3.2
Possible
84 / 86
47 - 63
+/-2
504
280
250
28
18
56
56
PFE500S-12
PFE500S-28, 48
-
-40°C - +100°C(Baseplate)
0
Baseplate Temperature (°C)
2
20
DENSEI-LAMBDA
40
2
) X,Y,Z 1 hour each
60
PFE500S-48
6.2 / 3.2
84 / 86
10.5
504
480
48
96
96
80
85
100

Related parts for PFE500S-48

PFE500S-48 Summary of contents

Page 1

... Output to Baseplate 500VDC more than 100MΩ (25°C,70%RH Operating, 10-55Hz (Sweep for 1min.) Amplitude 0.825mm Constant (Maximum 49.0m Approved by UL60950-1,CSA60950-1,EN60950 12.7 x 116.8 (Refer to Outline Drawing) Derating Curve 100 -40 DENSEI-LAMBDA PFE500S-28 PFE500S- 10.5 504 504 265 VAC 6.2 / 3.2 6.2 / 3.2 0.95 min +/-2 -20 / +20 280 480 56 96 ...

Page 2

... If the ambient temperature is less than -20°C, use twice the recommended capacitor above. *7. Refer to instruction manual for further details. Measurement point for output ripple & noise . (JEITA RC-9131A probe) Bandwidth of scope: 100MHz Measurement point for Vo load/line regulation. L2 AC( PFE500S *2,3 AC(N) TRIM BASE -PLATE ENA R +BC -BC ...