BP5038A Rohm Semiconductor, BP5038A Datasheet

IC CONV AC/DC 12V 30MA SIP6

BP5038A

Manufacturer Part Number
BP5038A
Description
IC CONV AC/DC 12V 30MA SIP6
Manufacturer
Rohm Semiconductor
Series
BP5038r
Datasheet

Specifications of BP5038A

Voltage - Output
12V
Number Of Outputs
1
Power (watts)
1W
Applications
Commercial
Power Supply Type
Switching (Closed Frame)
Voltage - Input
100VAC
Mounting Type
Through Hole
1st Output
12 VDC @ 30mA
Size / Dimension
0.71" L x 0.36" W x 0.66" H (18mm x 9.1mm x 16.8mm)
Power (watts) - Rated
0.4W
Operating Temperature
-20°C ~ 80°C
Efficiency
50%
Lead Free Status / RoHS Status
Lead free / RoHS Compliant
www.rohm.com
©2010 ROHM Co., Ltd. All rights reserved.
Non-Isolated AC/DC Converter
100VAC Input/12VDC (30mA) Output
BP5038A
∗1 Maximum output current varies depending on ambient temperature ; please refer to derating curve.
∗2 Please refer to Load regulation, Conversion efficiency.
External Component Specifications
Input voltage range
Output voltage
Output current
Line regulation
Load regulation
Output ripple voltage
Power conversion efficiency
Input voltage
Output current
ESD endurance
Operating temperature range
Storage temperature range
Absolute Maximum Ratings
Electrical Characteristics
Application Circuit
50Hz/60Hz
FUSE: Fuse
C1: Input smoothing
C2: Noise reduction
C3: Capacitor for Output
D1: Rectifier diode
R1: Noise reduction
ZNR: Varistor
AC100V
Input
BP5038A
Parameter
capacitor
resistor
capacitor
Please verify operation and characteristics in the customer's circuit before actual usage.
Ensure that the load current does not exceed the maximum rating.
voltage smoothing
1SR35−400A
Parameter
ZNR
220V
D1
+
10µF/200V
C1
10Ω1/4W
Symbol
R1
Vp
Vo
Vi
Vr
Vl
Io
η
Please make sure to use a fuse of 0.5A
Capacitance : 3.3 to 22µF
Rated voltage : 250V or higher
Capacitance : 0.1 to 0.22µF Rated voltage : 250V or higher
Use a film or ceramic capacitor and evaluate characteristics under actual
operating conditions.
Capacitance : 100 to 470µF Rated voltage : 25V or higher
Impedance is 0.39Ω max at high frequency range.
Ripple current is 0.1Arms above.
Capacitor impedance affects the output ripple voltage.
In the absolute maximum ratings, the reverse surge voltage should be
400V or higher, the average rectifying current should be 0.5A or higher,
and the forward surge current 20A or higher.
10 to 22Ω, 1/4W
Use for terminal voltage noise reduction. Determine the optimal value
through actual testing.
A varistor must be used to protect the part against lightning surges and
static electricity.
1
FUSE
Be sure to use fuse for safety.
0.5A
0.1µF
C2
Min.
11.0
113
40
0
4 5
Symbol
Vsurge
Topr
Tstg
+
6
Vi
Io
0.17
0.19
0.05
Typ.
141
100µF/50V
12
50
C3
Output
+12V
Max.
13.0
0.15
170
0.3
0.3
30
−20
−20
Limits
Vp-p
Unit
170
mA
Pin No.
30
%
to
to
2
V
V
V
V
1
2
3
4
5
6
+80
+85
Input terminal Vi(141VDC)
Skip
Skip
COMMON
COMMON
Output terminal Vo(12V)
1/1
DC(80
Vi=141V, Io=30mA
Vi=141V
Vi=113
Vi=141V, Io=0
Vi=141V, Io=30mA
Vi=141V, Io=30mA
Function
to
to
Conditions
170V, Io=30mA
120VAC)
mApk
Unit
kV
°C
°C
V
to
30mA
∗1
∗2
∗2
3 . 3 M A X
Dimensions (Unit :
Derating Curve
Switching Frequency
Conversion Efficiency
Load Regulation
Surface temperature Increase
140
120
100
13.0
12.8
12.6
12.4
12.2
12.0
11.8
11.6
11.4
11.2
11.0
40
35
30
25
20
15
10
80
60
40
20
60
50
40
30
20
10
40
30
20
10
5
0
-30 -20 -10
0
0
0
0
0
0
0
1
1.3±0.2
Surface Temperature Increase
Ambient Temperature Ta(
2.54�5=12.7
5
5
5
5
Output Current Io(mA)
Conversion Efficiency
18.0MAX.
Switching Frequency
(Ta=25°C, Vi=141V)
(Ta=25 °C , Vi=141V)
(Ta=25 °C , Vi=141V)
(Ta=25 °C , Vi=141V)
Output Current Io(mA)
Output Current Io(mA)
Output Current Io(mA)
0 . 5 ±0 . 1
0 10
Load Regulation
Data Sheet
Derating Curve
Operation Range
10
10
10
10
4
5
20
2010.01 - Rev.A
15
15
6
15
15
P = 2 . 5 4 ±0 . 2
30
40% Min−Line
40
20
20
20
20
50
°C
60
)
25
25
25
25
0 . 2 5 ±0 . 0 5
mm
70
80
30
30
30
30
)
9.1MAX.
90
6.1MAX.
3.0MAX.

Related parts for BP5038A

BP5038A Summary of contents

Page 1

... Load regulation Vl − Output ripple voltage Vp Power conversion efficiency η 40 ∗1 Maximum output current varies depending on ambient temperature ; please refer to derating curve. ∗2 Please refer to Load regulation, Conversion efficiency. Application Circuit BP5038A 1 FUSE R1 D1 0.5A 1SR35−400A 10Ω1/4W C2 Input ZNR + ...

Page 2

...

Page 3

...

Page 4

No copying or reproduction of this document, in part or in whole, is permitted without the consent of ROHM Co.,Ltd. The content specified herein is subject to change for improvement without notice. The content specified herein is for the purpose ...

Related keywords