LV E63C-ABCA-35 OSRAM Opto Semiconductors Inc, LV E63C-ABCA-35 Datasheet - Page 16

LED VERDGRN 503NM CLR 4-PLCC SMD

LV E63C-ABCA-35

Manufacturer Part Number
LV E63C-ABCA-35
Description
LED VERDGRN 503NM CLR 4-PLCC SMD
Manufacturer
OSRAM Opto Semiconductors Inc
Series
TOPLEDr
Datasheet

Specifications of LV E63C-ABCA-35

Color
Green
Luminous Flux @ Current - Test
1.45 lm
Millicandela Rating
2475mcd
Current - Test
30mA
Wavelength - Dominant
503nm
Wavelength - Peak
501nm
Voltage - Forward (vf) Typ
3.8V
Lens Type
Clear
Lens Style/size
Round, 2.6mm
Package / Case
4-PLCC
Size / Dimension
3.20mm L x 2.80mm W
Height
3.50mm
Viewing Angle
20°
Mounting Type
Surface Mount
Resistance Tolerance
503nm
Lead Free Status / RoHS Status
Contains lead / RoHS non-compliant
Other names
475-1026-2
LVE63CABCA35
Q65110A0257
Published by OSRAM Opto Semiconductors GmbH
Wernerwerkstrasse 2, D-93049 Regensburg
© All Rights Reserved.
Attention please!
The information describes the type of component and shall not be considered as assured characteristics.
All typical data and graphs are basing on representative samples, but don’t represent the production range. If requested,
e.g. because of technical improvements, these typ. data will be changed without any further notice.
Terms of delivery and rights to change design reserved. Due to technical requirements components may contain
dangerous substances. For information on the types in question please contact our Sales Organization.
If printed or downloaded, please find the latest version in the Internet.
Packing
Please use the recycling operators known to you. We can also help you – get in touch with your nearest sales office.
By agreement we will take packing material back, if it is sorted. You must bear the costs of transport. For packing
material that is returned to us unsorted or which we are not obliged to accept, we shall have to invoice you for any costs
incurred.
Components used in life-support devices or systems must be expressly authorized for such purpose! Critical
components
1
to cause the failure of that life-support device or system, or to affect its safety or the effectiveness of that device or
system.
2
and sustain human life. If they fail, it is reasonable to assume that the health of the user may be endangered.
2003-06-02
Revision History: 2003-06-02
Previous Version: 2002-11-08
Page
6
2
2
2; 5
16
14
3
2, 5
6
13
A critical component is a component used in a life-support device or system whose failure can reasonably be expected
Life support devices or systems are intended (a) to be implanted in the human body, or (b) to support and/or maintain
Subjects (major changes since last revision)
radiation characteristic
verde (one half-group up)
wavelength grouping for blue, true green and verde
changed to partial flux measurement
annotations
new IR solder pad (OHLPY439 to OHLPY440)
reverse voltage (footnote)
luminous flux values
Schematic Test Methode for partial flux measurement
new recommended solder pad
1
may only be used in life-support devices or systems
16
2
with the express written approval of OSRAM OS.
LB E63C, LV E63C, LT E63C
Date of change
2002-07-23
2002-08-05
2002-08-21
2002-11-08
2002-11-28
2003-06-02

Related parts for LV E63C-ABCA-35