・All specifications are subject to change without notice.
CXA-0538
■ Features
Electrical Characteristics
(*1) Please refer to the connection diagram for details of a dimming method.
(*2) Please refer to the connection diagram for details of alarm output.
(*3) As equivalent circuit of panel load, connect resistance load (RL) and distributed capacity (CL), and have provided by an electrical characteristic.
Other Specifications
(*4) These dimensions are indicated the maximum only H. Others are typical values.
Item
Output Current mArms
Input Current
Oscillatory
Frequency
Open Circuit
Voltage
Alarm Signal
Dimming
Function
Operating
Temperature
Storage
Temperature
Operating
Humidity Ratio
Safety
Standard
Weight
Dimensions
(WxDxH)
Fused Input
Remote ON / OFF
Alarm Signal
Function
Shutdown
Function
Silicone Coating on
High Voltage Area
●4 outputs
●UL60950-1 acquisition product
●Applicable panel size*: 14 to 17 inches
●With brightness control function (Pulse Width Modulation Dimming).
●With shut down function.
●With a sensing function for running out of lamp (alarm output).
●In the high-voltage generator (a terminal and a pattern), an anti-dust measure by
(Notice) Applicable panel size becomes a standard.
silicone application is taken.
CXA-0538 Specifications
Unit
A
mA
kHz
Hz
Vrms
V
℃
℃
RH%
g
mm
Symbol
Iout (Maximum
dimmer)
Iout (Minimum
dimmer)
Iin1
Iin2
Freq1
Freq2(Duty frequency)
Vopen
Vst
1700
150x50x8.5 (*4)
125
min
5.9
5.9
2.2
2.2
4.5
45
-
-
UL60950-1
-30 to +80
-30 to +85
Specifi cation
95max
46typ.
-
Yes
Yes
Yes
Yes
Yes
Yes
2000
155
6.5
6.5
3.0
3.0
5.0
typ
1.7
50
0
2300 12 ±1.2
max
185
3.8
3.8
2.5
5.5
0.5
7.1
7.1
55
1
12 ±1.2
12 ±1.2
12 ±1.2
12 ±1.2
12 ±1.2
12 ±1.2
12 ±1.2
12 ±1.2
12 ±1.2
12 ±1.2
Vin(V) Vrmt(V) Vbr(V)
(Please refer to each specification before use)
■ Applications
5
5
5
5
5
0
5
5
5
5
5
F A
0 to 2.5 0 to 50 -30 to +80
0 to 2.5 0 to 50 -30 to +80
0 to 2.5 0 to 50 -30 to +80
This means that, in conformity with EU Directive
2002/95/EC, lead, cadmium, mercury, hexavalent
chromium, and specific bromine-based flame
retardants, PBB and PBDE, have not been used,
except for exempted applications.
■ Conformity to RoHs Directive
2.5
2.5
0
-
-
MED
0
0
0
Condition
Rbr(kΩ)
50
50
0
-
-
MEASURE
-30 to +80
-30 to +80
-30 to +80
-30 to +80
-30 to +80
-30 to +80
-30 to +80
-30 to +80
Ta(℃ )
Dimming/Connector Type
RL(kΩ) CL(pF)(*3)
90
90
90
90
90
90
90
90
90
∞
∞
6
6
6
6
6
6
6
6
6
lamp anomaly
operation (*2)
Remote OFF
On a normal
Remote ON
dimmer (*1)
dimmer (*1)
dimmer (*1)
dimmer (*1)
Open load
In case of
Remarks
Voltage
Volume
Voltage
Volume
(*2)
C-151