Specifications of LD 261-5/6

Wavelength
950nm
Current - Dc Forward (if)
50mA
Radiant Intensity (ie) Min @ If
3.2mW/sr @ 50mA
Voltage - Forward (vf) Typ
1.25V
Viewing Angle
30°
Orientation
Top View
Mounting Type
Through Hole
Package / Case
6-DIP
Radiant Intensity
6.3 mW/sr, 10 mW/sr
Maximum Forward Current
50 mA
Maximum Power Dissipation
70 mW
Maximum Operating Temperature
+ 80 C
Minimum Operating Temperature
- 40 C
Lens Shape
Circular
Luminous Intensity
6.3/10mW/sr
Forward Current
50mA
Forward Voltage
1.4V
Product Length (mm)
2.4mm
Product Height (mm)
3.6mm
Product Depth (mm)
2.1mm
Mounting
Through Hole
Peak Wavelength
950nm
Shape Type
Circular
Chip Material
GaAs
Main Category
IrLED
Number Of Elements
1
Pin Count
2
Operating Temperature Classification
Commercial
Operating Temp Range
-40C to 80C
Reverse Voltage
5V
Power Dissipation
70mW
Lead Free Status / RoHS Status
Lead free / RoHS Compliant
Lead Free Status / RoHS Status
Lead free / RoHS Compliant, Lead free / RoHS Compliant
Other names
Q65110A3337
Lötbedingungen
Soldering Conditions
Wellenlöten (TTW)
TTW Soldering
Published by
OSRAM Opto Semiconductors GmbH
Wernerwerkstrasse 2, D-93049 Regensburg
www.osram-os.com
© All Rights Reserved.
The information describes the type of component and shall not be considered as assured characteristics.
Terms of delivery and rights to change design reserved. Due to technical requirements components may contain
dangerous substances. For information on the types in question please contact our Sales Organization.
Packing
Please use the recycling operators known to you. We can also help you – get in touch with your nearest sales office.
By agreement we will take packing material back, if it is sorted. You must bear the costs of transport. For packing
material that is returned to us unsorted or which we are not obliged to accept, we shall have to invoice you for any costs
incurred.
Components used in life-support devices or systems must be expressly authorized for such purpose! Critical
components
1
to cause the failure of that life-support device or system, or to affect its safety or effectiveness of that device or system.
2
and sustain human life. If they fail, it is reasonable to assume that the health of the user may be endangered.
2007-03-30
A critical component is a component usedin a life-support device or system whose failure can reasonably be expected
Life support devices or systems are intended (a) to be implanted in the human body, or (b) to support and/or maintain
T
300
250
200
150
100
1
50
C
0
, may only be used in life-support devices or systems
0
235 C
100
C
... 260
... 130
C
C
ca 200 K/s
1. Welle
1. wave
50
2 K/s
10 s
Zwangskühlung
forced cooling
5 K/s
100
(nach CECC 00802)
(acc. to CECC 00802)
6
2. Welle
2. wave
2 K/s
2
with the express written approval of OSRAM OS.
150
t
Normalkurve
standard curve
Grenzkurven
limit curves
200
s
OHLY0598
LD 261
250

Related parts for LD 261-5/6