SFH 4680-Z OSRAM Opto Semiconductors Inc, SFH 4680-Z Datasheet - Page 8

EMITTER 880NM MIDLED TOPLOOK SMD

SFH 4680-Z

Manufacturer Part Number
SFH 4680-Z
Description
EMITTER 880NM MIDLED TOPLOOK SMD
Manufacturer
OSRAM Opto Semiconductors Inc
Datasheet

Specifications of SFH 4680-Z

Wavelength
880nm
Package / Case
Non-Standard SMD
Current - Dc Forward (if)
100mA
Radiant Intensity (ie) Min @ If
20mW/sr @ 100mA
Voltage - Forward (vf) Typ
1.5V
Viewing Angle
40°
Orientation
Top View
Mounting Type
Surface Mount
Beam Angle
20 deg
Radiant Intensity
20 mW/sr
Maximum Forward Current
100 mA
Maximum Power Dissipation
180 mW
Maximum Operating Temperature
+ 100 C
Minimum Operating Temperature
- 40 C
Fall Time
500 ns
Lens Shape
Circular
Mounting Style
SMD/SMT
Operating Voltage
1.5 V
Rise Time
500 ns
Lead Free Status / RoHS Status
Lead free / RoHS Compliant
Lead Free Status / RoHS Status
Lead free / RoHS Compliant, Lead free / RoHS Compliant
Other names
475-1463-2
Q65110A1570
Lötbedingungen
Soldering Conditions
Reflow Lötprofil für bleifreies Löten
Reflow Soldering Profile for lead free soldering
Published by
OSRAM Opto Semiconductors GmbH
Wernerwerkstrasse 2, D-93049 Regensburg
www.osram-os.com
© All Rights Reserved.
The information describes the type of component and shall not be considered as assured characteristics.
Terms of delivery and rights to change design reserved. Due to technical requirements components may contain
dangerous substances. For information on the types in question please contact our Sales Organization.
Packing
Please use the recycling operators known to you. We can also help you – get in touch with your nearest sales office.
By agreement we will take packing material back, if it is sorted. You must bear the costs of transport. For packing
material that is returned to us unsorted or which we are not obliged to accept, we shall have to invoice you for any costs
incurred.
Components used in life-support devices or systems must be expressly authorized for such purpose! Critical
components
1
to cause the failure of that life-support device or system, or to affect its safety or effectiveness of that device or system.
2
2009-03-19
and sustain human life. If they fail, it is reasonable to assume that the health of the user may be endangered.
A critical component is a component usedin a life-support device or system whose failure can reasonably be expected
Life support devices or systems are intended (a) to be implanted in the human body, or (b) to support and/or maintain
T
1
, may only be used in life-support devices or systems
300
250
200
150
100
50
˚C
0
0
255 ˚C
240 ˚C
217 ˚C
25 ˚C
Ramp Up
3 K/s (max)
50
120 s max
100
Recommended Solder Profile
Maximum Solder Profile
Minimum Solder Profile
8
150
Vorbehandlung nach JEDEC Level 2
Preconditioning acc. to JEDEC Level 2
(nach J-STD-020C)
(acc. to J-STD-020C)
2
with the express written approval of OSRAM OS.
200
100 s max
30 s max
Ramp Down
6 K/s (max)
10 s min
SFH 4680, SFH 4685
t
250
260 ˚C
245 ˚C
235 ˚C
OHLA0687
s
+0 ˚C
-5 ˚C
+5 ˚C
-0 ˚C
±5 ˚C
300

Related parts for SFH 4680-Z