DMF-50174ZNF-FW Optrex America Inc, DMF-50174ZNF-FW Datasheet
DMF-50174ZNF-FW
Specifications of DMF-50174ZNF-FW
Related parts for DMF-50174ZNF-FW
DMF-50174ZNF-FW Summary of contents
Page 1
... Optical Specifications..................................................................8 4. I/O Terminal............................................................................10 5. Test........................................................................................12 6. Appearance Standards................................................................13 7. Code System of Production Lot................................................16 8. Type Number...........................................................................16 9. Applying Precautions................................................................16 10. Handling Precautions................................................................17 Rev. Date DMF-50174ZNF-FW (AS) No.98-0089 First Edition April 23, 1998 Final Revision ******* Table of Contents Revision History Page OPTREX CORPORATION Approved by Production Div ...
Page 2
... Viewing Area : Outline Dimensions : Weight : 300g max. LCD Type : Viewing Angle : Data Transfer : Backlight : Drawings : DMF-50174ZNF-FW (AS) No.98-0089 min. 0˚C ~ max. 50˚C min. –20˚C ~ max. 60˚C 320 (W) 240 (H) dots 0.33 (W) 0.33 (H) mm 0.36 (W) 0.36 (H) mm 122.0 (W) 92.0 ( 174.0 (W) 112.0 (H) 13.5 max. (D) mm ...
Page 3
... Supply Voltage (LCD Drive ADJ High Level V IH Input Voltage Low Level V IL Input Voltage I CC Supply Current Clock Frequency CP DMF-50174ZNF-FW (AS) No.98-0089 Conditions Min. – -0.3 – 0 – -0.3 Conditions Min. – 4.5 – 26.8 Shown in 3.1 V =5.0V±10% 0 =5.0V±10% ...
Page 4
... Note 1:The rise and fall times ( < – < LOAD 0~DI 3 FLM This module contain these capacitors. Please be careful about timing characteristics. FLM LP M VSS DMF-50174ZNF-FW (AS) No.98-0089 Symbol Min SETUP t HOLD 110 100 FDS t 100 FDH must satisfy the following relationships ( and ). t WL ...
Page 5
... D0 SEG SEG SEG ~ ~ ~ 313 317 1 D3 316 320 4 FLM LP (Reduction) FLM (Reduction) M 2.5. Comparison of Display and Data SEG1 # #240 DMF-50174ZNF-FW (AS) No.98-0089 T=0.0595ms typ. SEG #1 DATA ~ 5 8 240 TOP VIEW D0~D3 OPTREX CORPORATION SEG SEG SEG SEG ~ ~ ~ ~ 313 317 1 5 316 320 ...
Page 6
... Please maintain the above sequence when turning on and off the power supply of the module. If DISPOFF is supplied to the module while internal alternate signal for LCD driving (M) is unstable, DC component will be supplied to the LCD panel. This may cause damage the LCD module. DMF-50174ZNF-FW (AS) No.98-0089 ...
Page 7
... Note 5 : CFL life is defined as the time for which the initial luminance is attenuated by 50% of the luminance value. Average Life representes the time elapsed at the point of time when the residual ratio becomes below 50% when plural lamps are lighted in comparison with the definition of life mentioned above DMF-50174ZNF-FW (AS) No.98-0089 Conditions Min. Typ. – – 220 – ...
Page 8
... Duty - 1/B Bias ( A : Duty Number Bias Number ). Driving voltage V as the voltage V when the contrast ratio (CR=L O (ON SIGNAL) DMF-50174ZNF-FW (AS) No.98-0089 Conditions Ta= 0˚C -V Ta=25˚C ADJ Ta=50˚C Ta=25˚C, 1/240 Duty, 1/14 Bias, V Conditions CR = 0˚, = –˚ ...
Page 9
... Duty, 1/14 Bias, V 90˚ 135˚ 180˚ 225˚ 270˚ • 3.4. System Block Diagram Photometer #1980A WB Computer DMF-50174ZNF-FW (AS) No.98-0089 f =22.6V, =70Hz D F 45˚ 0˚) 180˚ 315˚ 270˚ Temperature Chamber Rotation Table ( , ) Control Unit & ...
Page 10
... GND 4.2. Example of Power Supply It is recommended to apply a potentiometer for the contrast adjust due to the tolerance of the driving voltage and its temperature dependence. MODULE DMF-50174ZNF-FW (AS) No.98-0089 Level First Line Marker Data Latch Signal Clock Signal for Shifting Data Alternate Signal for LCD Drive – ...
Page 11
... Block Diagram FLM LP M DISPOFF CP D0~D3 LP VCC VSS VADJ VEE FL HOT FL GND DMF-50174ZNF-FW (AS) No.98-0089 Row Driver 240 LC79431D 3 or equivalent Circuit Bias Circuit To LSI CFL Backlight OPTREX CORPORATION 320 240 dots 320 Column Driver LC79401D 4 or equivalent Page 11/17 ...
Page 12
... Note 4 : The function test shall be conducted after 4 hours storage at the normal temperature and humidity after removed from the test chamber. Note 5 : Vibration test will be conducted to the product itself without putting container. DMF-50174ZNF-FW (AS) No.98-0089 Conditions 50˚C±2˚C, 96hrs (operation state) 0˚C±2˚C, 96hrs (operation state) 60˚ ...
Page 13
... All directions for inspecting the sample should be within 45˚against perpendicular line. 6.2. Definition of applicable Zones A Zone : Active display area B Zone : Area from outside of "A Zone" to validity viewing area C Zone : Rest parts A Zone + B Zone = Validity viewing area DMF-50174ZNF-FW (AS) No.98-0089 45˚ A Zone Bezel Flame B Zone C Zone ...
Page 14
... Black and (1) Round Shape White Spots, Foreign Substances (2) Line Shape Total defects shall not exceed 5. 2 Air Bubbles (between glass & polarizer) Total defects shall not exceed 3. DMF-50174ZNF-FW (AS) No.98-0089 Criteria Zone Dimension (mm 0.1 * 0.1 < D 0.2 3 0.2 < D 0.25 2 0.25< D 0.3 0 0.3 < ...
Page 15
... Black spots, line shaped foreign substances or air bubbles between Substance Defects glass & polarizer should be 5pcs maximum in total. 7 Distance between D 0.2 : 20mm or more Different Foreign 0.2<D : 40mm or more Substance Defects DMF-50174ZNF-FW (AS) No.98-0089 Criteria 0. OPTREX CORPORATION As per the sketch of left hand. Should not be connected to next dot. ...
Page 16
... Production Year (Lower 2 digits) 8. Type Number The type number of module is specified on the back of module as follows – – Applying Precautions Please contact us when questions and/or new problems not specified in this specifications arise. DMF-50174ZNF-FW (AS) No.98-0089 ¨ ¨ Factory Number (Numeral) Factory Code (Alphabet) Production Week (1~5) ...
Page 17
... And please set the cable properly in the housing to avoid a worn-out of isolated cover of cable wire. Optrex shall not be responsible for any infringement of industrial property rights of third parties in any country arising out of the application or use of Optrex Products, except which directly concern the structure or production of such products. DMF-50174ZNF-FW (AS) No.98-0089 (GND) is not specified in the module. SS OPTREX CORPORATION ...