NHD-0220D3Z-NSW-BBW Newhaven Display, NHD-0220D3Z-NSW-BBW Datasheet - Page 7
NHD-0220D3Z-NSW-BBW
Manufacturer Part Number
NHD-0220D3Z-NSW-BBW
Description
LCD MOD SERIAL 2X20 BLU TRANSM
Manufacturer
Newhaven Display
Datasheet
1.NHD-0220D3Z-NSW-BBW.pdf
(14 pages)
Specifications of NHD-0220D3Z-NSW-BBW
Display Type
STN - Super-Twisted Nematic
Display Mode
Transmissive
Number Of Digits/alpha
40
Outline L X W X H
116.00mm x 37.00mm x 13.50mm
Viewing Area
83.00mm L x 18.60mm W
Backlight
LED - White
Display Format
20 x 2
Character Size
5.55mm H x 3.20mm W
Character Format
5 x 8 Dots
Voltage - Supply
4.7 V ~ 5.5 V
Dot Size
0.60mm W x 0.65mm H
Interface
Serial
Operating Temperature
-20°C ~ 70°C
Character Count X Line
20 x 2
Module Size (w X H X T)
116 mm x 37 mm x 13.5 mm
Fluid Type
STN Negative
Background Color
Blue
Voltage Rating
5 V
Operating Temperature Range
- 20 C to + 70 C
Backlight Type
Side LED White
Lead Free Status / RoHS Status
Lead free / RoHS Compliant
Lead Free Status / RoHS Status
Lead free / RoHS Compliant, Lead free / RoHS Compliant
Table of Commands
Changing the I2C Slave Address
Prefix
0xFE
0xFE
0xFE
0xFE
0xFE
0xFE
0xFE
0xFE
0xFE
0xFE
0xFE
0xFE
0xFE
0xFE
0xFE
0xFE
0xFE
0xFE
0xFE
0xFE
0xFE
0xFE
Description
Syntax
Parameter
CMD
0x4A
0x41
0x42
0x45
0x46
0x47
0x48
0x49
0x4B
0x4C
0x4E
0x51
0x52
0x53
0x54
0x55
0x56
0x61
0x62
0x70
0x71
0x72
This command sets the I2C address, the address must be an even number, (LSB = 0). The
address change requires 20 microsecond to take effect; therefore, the subsequent input
must have an appropriate delay. The default I2C address can be restored if SPI or RS232
is selected as the communication mode.
hexadecimal 0xFE 0x62 [adr]
Parameter
[adr]
Default
Param
1 Byte
1 Byte
1 Byte
9 Byte
1 Byte
1 Byte
None
None
None
None
None
None
None
None
None
None
None
None
None
None
None
None
Length
1 byte
0x50
Display on
Display off
Set cursor
Cursor home
Underline cursor on
Underline cursor off
Move cursor left one place
Move cursor right one place
Blinking cursor on
Blinking cursor off
Backspace
Clear screen
Set contrast
Set backlight brightness
Load custom character
Move display one place to the left
Move display one place to the right
Change RS232 BAUD rate 232
Change I2C address
Display firmware version number
Display RS232 BAUD rate
Display I2C address
Description
New I
The LSB is always ‘0’.
[7]
2
C address, 0x00 – 0xFE
Description