NHD-0216K3Z-NSW-BBW Newhaven Display, NHD-0216K3Z-NSW-BBW Datasheet - Page 9

LCD MOD SERIAL 2X16 BLU TRANSM

NHD-0216K3Z-NSW-BBW

Manufacturer Part Number
NHD-0216K3Z-NSW-BBW
Description
LCD MOD SERIAL 2X16 BLU TRANSM
Manufacturer
Newhaven Display
Datasheet

Specifications of NHD-0216K3Z-NSW-BBW

Display Type
STN - Super-Twisted Nematic
Display Mode
Transmissive
Number Of Digits/alpha
32
Outline L X W X H
80.00mm x 36.00mm x 13.50mm
Viewing Area
64.50mm L x 16.40mm W
Backlight
LED - White
Display Format
16 x 2
Character Size
5.23mm H x 3.00mm W
Character Format
5 x 8 Dots
Voltage - Supply
4.7 V ~ 5.5 V
Dot Size
0.56mm W x 0.61mm H
Interface
Serial
Operating Temperature
-20°C ~ 70°C
Character Count X Line
16 x 2
Module Size (w X H X T)
80 mm x 26.3 mm x 13.5 mm
Fluid Type
STN Negative
Background Color
Blue
Voltage Rating
5 V
Operating Temperature Range
- 20 C to + 70 C
Backlight Type
LED White
Lead Free Status / RoHS Status
Lead free / RoHS Compliant
Lead Free Status / RoHS Status
Lead free / RoHS Compliant, Lead free / RoHS Compliant
 
Set Cursor Position 
Home Cursor 
 
Turn On Underline Cursor 
 
Turn Off Underline Cursor 
 
 
 
 
Syntax  
 
Parameter 
 
 
Default 
 
Syntax  
 
Parameter 
 
Syntax  
 
Parameter 
 
 
Syntax  
 
Parameter 
 
Description
Description
Description
Default 
Description This command move the cursor to line 1, column 1 of the LCD screen, the display text is not altered.
Default  The underline cursor is off. 
Line 2 
Line 3 
Line 4 
Line1 
 
.
 
 
 
 
 
 
This command moves the cursor to a specified location where the next character will be displayed. The
typical cursor position for a 4-line display is show below; a cursor position outside these ranges will not
be viewable.
This command turns on the underline cursor, the cursor position is where the next character will
appear.
hexadecimal  0xFE  0x45 [pos] 
        
Parameter 
After a reset, the cursor is on position 0x00. 
hexadecimal  0xFE  0x46 
        
Parameter 
       None 
hexadecimal  0xFE  0x47 
        
Parameter 
       None 
hexadecimal  0xFE  0x48 
        
Parameter 
       None 
This command turns off the underline cursor.
[pos] 1 byte Put cursor at location specified by [pos], 0x00 to 0x67
The underline cursor is off. 
Default 
Column1
 
 
 
 
0x00 
0x40 
0x14 
0x54 
 
Length  
 
Length  
 
None 
 
Length  
 
 
Length  
 
Column20
 
 
None   
 
None   
 
None   
0x13 
0x53 
0x27 
0x67 
 
Description 
 
Description 
 
Description 
 
Description 
[9] 
 
 
 
Position cursor at line 1 column 1 
 
Turn on underline cursor 
 
Turn off underline cursor 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
           
 
 
 
           
 
           
 

Related parts for NHD-0216K3Z-NSW-BBW