NHD-0420D3Z-FL-GBW Newhaven Display, NHD-0420D3Z-FL-GBW Datasheet

LCD MOD CHAR 4X20 SERIAL TRANSFL

NHD-0420D3Z-FL-GBW

Manufacturer Part Number
NHD-0420D3Z-FL-GBW
Description
LCD MOD CHAR 4X20 SERIAL TRANSFL
Manufacturer
Newhaven Display
Datasheet

Specifications of NHD-0420D3Z-FL-GBW

Display Type
STN - Super-Twisted Nematic
Display Mode
Transflective
Number Of Digits/alpha
80
Outline L X W X H
98.00mm x 60.00mm x 13.50mm
Viewing Area
76.00mm L x 25.20mm W
Backlight
LED - Yellow/Green
Display Format
20 x 4
Character Size
4.75mm H x 2.95mm W
Character Format
5 x 8 Dots
Voltage - Supply
5.0V
Dot Size
0.55mm W x 0.55mm H
Interface
I²C
Operating Temperature
-10°C ~ 55°C
Character Count X Line
20 x 4
Module Size (w X H X T)
98 mm x 60 mm x 13.5 mm
Fluid Type
STN
Background Color
Gray
Backlight Type
LED Yellow / Green
Lead Free Status / RoHS Status
Lead free / RoHS Compliant
Lead Free Status / RoHS Status
Lead free / RoHS Compliant, Lead free / RoHS Compliant
 
 
NHD‐0420D3Z‐FL‐GBW 
Serial Liquid Crystal Display Module 
 
NHD‐   
0420‐   
D3Z‐ 
F‐ 
L‐ 
G‐ 
B‐ 
W‐ 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
Newhaven Display 
4 lines x 20 characters 
Model 
Transflective 
Yellow/Green LED Backlight 
STN‐Gray 
6:00 view 
Wide Temperature (‐20°C~ +70°C) 
RoHS Compliant 
 
 
 
 
nhtech@newhavendisplay.com   
 
 
 
 
 
 
 
 
 
 
 
 
 
www.newhavendisplay.com 
Newhaven Display International, Inc. 
2511 Technology Drive, Suite 101 
Elgin IL, 60124 
Ph: 847‐844‐8795 
 
[1] 
nhsales@newhavendisplay.com 
Fax: 847‐844‐8796 

Related parts for NHD-0420D3Z-FL-GBW

NHD-0420D3Z-FL-GBW Summary of contents

Page 1

... NHD‐0420D3Z‐FL‐GBW  Serial Liquid Crystal Display Module    NHD‐    Newhaven Display  0420‐    4 lines x 20 characters  D3Z‐    Model  F‐    Transflective  ...

Page 2

Document Revision History  Revision  Date  0  7/11/2007  1  8/21/2009  2  10/23/2009  3  3/31/2010            Functions and Features  • 4 lines x 20 characters  • Serial Interface: I2C, SPI or RS232/TTL   • +5.0V power supply  • 1/16 duty, 1/5 bias  • 5x8 pixels with cursor  • RoHS Compliant                      ...

Page 3

Mechanical Drawing    [3]  ...

Page 4

Pin Description  Pin No.  Symbol  External  Connection  1  RX  MPU  2  VSS  Power Supply  3  VDD   Power Supply      1  SPISS  MPU  2  SDO  NC  3  SCK/SCL  MPU  4  SDI/SDA  MPU  5  VSS  Power Supply  6  VDD  Power Suppy        1  VPP  ...

Page 5

Electrical Characteristics  Item  Operating Temperature Range  Storage Temperature Range  Supply Voltage  Supply Current  Supply for LCD (contrast)  “H” Level input  “L” Level input  “H” Level output  “L” Level output    Backlight Supply Current       Optical Characteristics  Item  Viewing Angle ‐ Vertical  Viewing Angle ‐ Horizontal  Contrast Ratio  Response Time (rise)  Response Time (fall)                                    ...

Page 6

Communication Information  This display uses a built‐in PIC 16F690 for serial communication.    I2C protocol:  To enter the I2C mode, place a jumper on R1.   SDA and SDK have pull‐up resistors (10K Ohm) on R7 and R8.  The default I2C address is 80 (50 hex).  The I2C address can be changed to any 8‐bit value by command function, with  the exception that the LSB (least significant bit) must always be ‘0’.  Once the I2C address has been changed, it will be  saved in the system memory, and it will revert back to the default address if either RS232 or SPI protocol is selected.  The I2C interface is capable of receiving data at up to 100KHz‐clock rate.      SPI protocol:  To enter the SPI  mode, place a jumper on R2.   SPI mode has a normally high level idle clock. When Slave Select is LOW, data is sampled on the rising edge of the  Clock.  The SPI interface is capable of receiving data at up to 100KHz‐clock rate.        RS232 protocol:  To enter the RS232  mode, both R1 and R2 should be open.   The RS232 signal must be 5V TTL compatible. Communication format is 8‐bit data, 1 Stop bit, no parity, no hand‐ shaking. Default BAUD rate is 9600, and is changeable with a command function. Once the BAUD rate has been  changed, it will be saved in the system memory, and it will revert back to the default address if either I2C or SPI  protocol is selected.            ASCII TEXT To display normal text, just enter its ASCII number. A number from 0x00 to 0x07 displays the user  defined custom character, 0x20 to 0x7F displays the standard set of characters, 0xA0 to 0xFD display  characters and symbols that are factory‐masked on the SPLC780D controller. 0xFE is reserved.          ...

Page 7

Table of Commands    Prefix  CMD  Param  0xFE  0x41  None  0xFE  0x42  None  0xFE  0x45  1 Byte  0xFE  0x46  None  0xFE  0x47  None  0xFE  0x48  None  0xFE  0x49  None  0xFE  0x4A  None  0xFE  0x4B  None  0xFE  0x4C  None  0xFE  0x4E  None  0xFE  0x51  ...

Page 8

Changing BAUD Rate  Syntax   hexadecimal  0xFE  0x61  [baud]                 Parameter  Parameter             [baud]  Description This command sets the RS232 BAUD rate, the single byte parameter select the desired BAUD rate as in the table below. The new BAUD ...

Page 9

Set Cursor Position  Syntax   hexadecimal  0xFE  0x45 [pos]                 Parameter  Parameter  [pos] 1 byte Put cursor at location specified by [pos], 0x00 to 0x67   Description This command moves the cursor to a specified location where the next character ...

Page 10

Move Cursor Left One Space  Syntax   hexadecimal  0xFE  0x49                Parameter  Parameter             None  Description This command moves the cursor position left 1 space, regardless the cursor is displayed or not, and the displayed character is not altered Default  ...

Page 11

Clear Screen  Syntax   hexadecimal  0xFE  0x51                 Parameter  Parameter  None None Clear LCD and move cursor to line 1 column 1. Description This command clears the entire display and place the cursor at line 1 column 1. ...

Page 12

Shift Display to the Left  Syntax   hexadecimal  0xFE  0x55                 Parameter  Parameter  None None Shift the LCD screen to the left one Place. Description This command shifts the display one place to the left, the cursor position also moves ...

Page 13

Built‐in Font Table           [13]    ...

Page 14

Example Initialization Program  http://www.newhavendisplay.com/app_notes/Serial_LCD.txt  See program code at      Quality Information  Test Item  High Temperature storage  storage temperature for a long time.  Low Temperature storage  Endurance test applying the low storage  temperature for a long time.  High Temperature  Endurance test applying the electric stress  Operation  (voltage & current) and the high thermal  stress for a long time.  Low Temperature  Endurance test applying the electric stress  Operation  (voltage & current) and the low thermal  stress for a long time.  High Temperature /  Endurance test applying the electric stress  Humidity Operation  (voltage & current) and the high thermal  with high humidity stress for a long time.  Thermal Shock resistance  Endurance test applying the electric stress  (voltage & current) during a cycle of low  and high thermal stress.   Vibration test  Endurance test applying vibration to  simulate transportation and use.  Static electricity test  Endurance test applying electric static  discharge.  ...