SMART1000RM1U Tripp Lite, SMART1000RM1U Datasheet - Page 3

UPS 1KVA 640W 6OUT RACK MOUNT

SMART1000RM1U

Manufacturer Part Number
SMART1000RM1U
Description
UPS 1KVA 640W 6OUT RACK MOUNT
Manufacturer
Tripp Lite
Series
Smart Pro®r
Type
Power Supply Regulatorr
Datasheets

Specifications of SMART1000RM1U

Rohs Status
Not applicable
Power - Rated
1kVA / 640W
Ac Outlets
6 (3 UPS, 3 Surge Only)
Features
DB9 and USB Communications, Rack Mount
Backup Time - Max Load
10 minutes
Voltage - Output Per Connector
120V
Voltage - Input
120V / 15A
Cord Length
10' (3.05m)
Ac Input Connector
NEMA 5-15P
Connector - Ac Output
4 NEMA 5-15R, 4 NEMA 5-15/20R and 1 NEMA L5-30R
Size
16.75" L x 17.50" W x 1.75" H (425.5mm x 444.5mm x 44.5mm)
Weight
32 lbs (14.5kg)
Ac Output Connector
4 NEMA 5-15R, 4 NEMA 5-15/20R and 1 NEMA L5-30R
Brand/series
SmartPro®
Capacity
1000 VA
Color
Black
Communication
DB9, RJ11, USB
Current, Rating
9.2 A (Input)
Dimensions
15.9cmH×60cmW×57.2cmD
Frequency, Output
60 Hz
Input Type
NEMA 5-15P
Length, Cord
10 ft.
Mounting Type
Rack/Tower
Operation
Line-Interactive
Output Type
(6) NEMA 5-15R
Power, Rating
640 W
Standards
cUL, UL Listed
Temperature, Operating
0 to +40 °C
Time, Backup
7 min.
Voltage Regulation
120 VAC (Sine Wave Output) within 5% @ Battery Mode
Voltage, Battery
24 VDC
Voltage, Input
120 V
Voltage, Nominal
120 VAC (Output)
Voltage, Output
120 VAC
Voltage, Supply
640/1000 W/VA
Power Rating
1000 VA
Output Voltage Rating
120 V
Number Of Outlets
6
Interface Port
USB / DB9
Runtime (full Load)
10 min
Runtime (half Load)
25 min
Topology
Line Interactive
Tower / Rackmount
Tower / Rackmount
Media Lines Protected
-
Lead Free Status / Rohs Status
RoHS Compliant part
Other names
TL243
UPS input connection type
Input circuit breaker
Recommended Electrical
Service
Input cord length (ft.)
Input cord length (m)
BATTERY
Full load runtime (minutes)
Half load runtime
(minutes)
DC system voltage (VDC)
Battery recharge rate
(included batteries)
Replacement battery
cartridge (internal UPS
battery replacement)
Battery Access
Battery replacement
description
VOLTAGE REGULATION
Voltage regulation
description
Overvoltage correction
Undervoltage correction
LEDS ALARMS & SWITCHES
LED Indicators
Alarms
Alarm cancel operation
Switches
SURGE / NOISE SUPPRESSION
UPS AC suppression
joule rating
EMI / RFI AC noise
suppression
AC suppression response
time
PHYSICAL
Installation form factors
supported with included
accessories
Primary form factor
5-15P
15A
15A 120V
10
3
7 min. (640w)
15 min. (320w)
24
Less than 4 hours from 10% to 90%
RBC64-1U
Front panel battery access door
Hot-swappable, user replaceable batteries
Automatic voltage regulation (AVR) maintains line power operation with an input voltage range of 83 to 147
Input voltages between 128 and 147 are reduced by 12%
Input voltages between 83 and 107 are boosted by 14%
5 LEDs indicate line power, battery power, overload, voltage regulation and battery low/replace status
Audible alarm indicates power-failure, overload and low-battery conditions
Power-fail alarm can be silenced using alarm-cancel switch; once silenced, alarm will re-sound to indicate
low-battery status
2 Switches control off/on power status and alarm-cancel/self-test operation
480 joules
Yes
Instantaneous
4 post 19 inch rackmount (mounting kit included); 2 post 19 inch rackmount (mounting kit included)
Rackmount

Related parts for SMART1000RM1U