BATT BACKUP 980W W/CDROM SOFTWR

SMART1500

Manufacturer Part Number
SMART1500
Description
BATT BACKUP 980W W/CDROM SOFTWR
Manufacturer
Tripp Lite
Series
Smart Pro®r
Type
UPSr
Datasheets

Specifications of SMART1500

Power - Rated
1.5kVA / 980W
Ac Outlets
6 (UPS)
Features
USB Communication Port, USB Cable
Backup Time - Max Load
7 minutes
Voltage - Output Per Connector
120V
Voltage - Input
120V / 15A
Cord Length
6' (1.83m)
Ac Input Connector
NEMA 5-15P
Connector - Ac Output
NEMA 5-15R
Size
9.00" L x 7.50" W x 12.75" H (228.6mm x 190.5mm x 323.9mm)
Weight
39 lbs (17.7kg)
Ac Output Connector
NEMA 5-15R
Brand/series
SmartPro®
Capacity
1500 VA
Color
Gray
Communication
DB9, USB
Current, Rating
12 A (Max.) Input⁄1070 W
Dimensions
32.4cmH×19.1cmW×22.9cmD
Frequency, Output
60 Hz
Input Type
NEMA 5-15P
Length, Cord
6 ft.
Mounting Type
Rack/Tower
Operation
Line-Interactive
Output Type
(6) NEMA 5-15R
Power, Rating
980 W
Standards
cUL, UL Listed
Temperature, Operating
+32 to +104 °F
Time, Backup
7 min.
Voltage Regulation
120 V (Sine Wave Output) within ± 18% @ Line Mode
Voltage, Battery
36 VDC
Voltage, Input
120 V
Voltage, Nominal
120 VAC (Output)
Voltage, Output
120 VAC
Voltage, Supply
980/1500 W/VA
Power Rating
1500 VA
Output Voltage Rating
120 V
Number Of Outlets
6
Interface Port
USB / DB9
Runtime (full Load)
7 min
Runtime (half Load)
20 min
Topology
Line Interactive
Tower / Rackmount
Tower
Lead Free Status / RoHS Status
Lead free / RoHS Compliant
Media Lines Protected
-
Lead Free Status / Rohs Status
RoHS Compliant part
Other names
TL290
Nominal Input Voltage(s)
Supported
UPS input connection
type
Input circuit breaker
UPS Input cord length
(ft.)
UPS Input cord length
(m)
Recommended Electrical
Service
BATTERY
Full load runtime
(minutes)
Half load runtime
(minutes)
DC system voltage (VDC)
Battery recharge rate
(included batteries)
Replacement battery
cartridge (internal UPS
battery replacement)
Battery Access
Battery replacement
description
VOLTAGE REGULATION
Voltage regulation
description
Overvoltage correction
Undervoltage correction
Severe undervoltage
correction
LEDS ALARMS & SWITCHES
LED Indicators
Alarms
Alarm cancel operation
Switches
SURGE / NOISE SUPPRESSION
UPS AC suppression
joule rating
UPS AC suppression
response time
EMI / RFI AC noise
suppression
120V AC
5-15P
15A
6
1.8
15A 120V
7 min. (980w)
20 min. (490w)
36V DC
Less than 4 hours from 10% to 90%
RBC53
Battery access door
Hot-swappable, user replaceable batteries
Automatic voltage regulation (AVR) maintains line power operation with an input voltage range of 75 to 147
Input voltages between 128 and 147 are reduced by 12%
Input voltages between 93 and 107 are boosted by 14%
Input voltages between 75 and 92 are boosted by 30%
5 LEDs indicate line power, battery power, overload, voltage regulation and battery low/replace status
Audible alarm indicates power-failure, overload and low-battery conditions
Power-fail alarm can be silenced using alarm-cancel switch; once silenced, alarm will re-sound to indicate
low-battery status
2 Switches control off/on power status and alarm-cancel/self-test operation
480
Instantaneous
Yes