1584SR Hammond Manufacturing, 1584SR Datasheet - Page 34

RECEPTACLE SINGLE SQUARE 15A

1584SR

Manufacturer Part Number
1584SR
Description
RECEPTACLE SINGLE SQUARE 15A
Manufacturer
Hammond Manufacturing
Datasheet

Specifications of 1584SR

Data Line Protection
N
Output Voltage
125 VoltsAC
Current Rating
15 Amps
Product
Accessories
Lead Free Status / RoHS Status
Lead free / RoHS Compliant
Lead Free Status / RoHS Status
Lead free / RoHS Compliant, Lead free / RoHS Compliant
34
Straight Isolation
• AC regulating - protects against both brownouts & over voltage conditions.
• Protects against any power problem other than a blackout.
• Will operate through a 3 millisecond (minimum) blackout.
• Long life - ferroresonant design - no moving parts.
• Ferroresonant design also filters out surges, line harmonics, and RF noise.
• Input 120VAC (+10 % to -25 %), 60 Hz
• Output 120VAC (+/- 3 %).
• Provides circuit isolation.
• Noise Isolation (RF) of 120 db common mode, 60 db normal mode.
• Spike attenuation: 250:1 minimum.
• Sine wave output - total harmonic distortion (THD): 3 %
• Units also include a 2nd stage of high frequency filtering on the output - a Hammond Mfg. exclusive.
• Operating temperature range of -40 degrees C to +40 degrees C.
• Standard 3-wire, grounded plug & receptacle.
• Front panel lighted power switch.
• Input (primary) connected to an extra long 15 foot, heavy duty 14/3 SJTW cord for extreme temperature ranges.
• Integral molded, standard North American plug (NEMA 5-15P).
• Output (secondary) connected to a rear mounted, standard North American, grounded receptacle (NEMA 5-15R) -
quantity depends on power capacity of unit (see table below).
• Rugged two piece ventilated steel enclosure.
• Finished in a grey/beige color, textured powder paint with rubber feet installed.
• NOTE 1: Due to the nature of ferroresonant designs - these units do produce audible noise. We have reduced this
through careful design, but these units are NOT usable in an office environment.
• NOTE 2: These units provide complete isolation from the source voltage. In other words, the "neutral" output wire has
no connection to ground, this is a UL requirement for this type of device. Therefore plug-in circuit testers
& line "polarity" testing devices will NOT function on the output as it is completely isolated.
• North American Mark of Safety: C UL & UL listed (File #E211544).
CV1201200
CV1201800
CV120300
CV120600
Part No.
Constant Voltage - Plug In (CV Series)
1200
1800
300
600
VA
Capacity
www.hammondmfg.com
(RMS)
Amps
2�5
10
15
A.C. Regulator - Plug In
5
(120 V to 120V)
Constant Voltage
Rear Outlets
Number of
2
4
4
6
Height
12�00
7�00
9�00
9�00
Dimensions (Inches)
Width
10�13
10�13
12�13
7�13
Depth
12�30
19�50
19�50
20�50
Lbs.
25�3
Wt.
48
74
95

Related parts for 1584SR