ACPL-K63L-500E Avago Technologies US Inc., ACPL-K63L-500E Datasheet - Page 5

OPTOCOUPLER 15MBD 3.3V 8-SOIC

ACPL-K63L-500E

Manufacturer Part Number
ACPL-K63L-500E
Description
OPTOCOUPLER 15MBD 3.3V 8-SOIC
Manufacturer
Avago Technologies US Inc.
Datasheet

Specifications of ACPL-K63L-500E

Voltage - Isolation
3750Vrms
Number Of Channels
2, Unidirectional
Current - Output / Channel
50mA
Data Rate
15MBd
Propagation Delay High - Low @ If
75ns @ 7.5mA
Current - Dc Forward (if)
15mA
Input Type
DC
Output Type
Open Collector
Mounting Type
Surface Mount
Package / Case
8-SOP
No. Of Channels
2
Optocoupler Output Type
Logic Gate
Input Current
15mA
Output Voltage
7V
Opto Case Style
SOIC
No. Of Pins
8
Input Current Max
230mA
Isolation Voltage
5kV
Number Of Elements
2
Forward Voltage
1.75V
Forward Current
15mA
Output Current
50mA
Operating Temp Range
-40C to 85C
Power Dissipation
60mW
Propagation Delay Time
90ns
Pin Count
8
Mounting
Surface Mount
Reverse Breakdown Voltage
5V
Operating Temperature Classification
Industrial
Operating Temperature Range
-40°C To +85°C
Rohs Compliant
Yes
Lead Free Status / RoHS Status
Lead free / RoHS Compliant
Lead Free Status / RoHS Status
Lead free / RoHS Compliant, Lead free / RoHS Compliant

Available stocks

Company
Part Number
Manufacturer
Quantity
Price
Part Number:
ACPL-K63L-500E
Manufacturer:
AVAGO
Quantity:
1 000
Insulation and Safety elated Specifications
Parameter
Minimum External Air
Gap (External Clearance)
Minimum External Tracking
(External Creepage)
Minimum Internal Plastic
Gap (Internal Clearance)
Tracking Resistance
(Comparative Tracking
Index)
Isolation Group
I C/ /DI
Description
Installation classification per DIN VDE 0110/1.89, Table 1
Climatic Classification
Pollution Degree (DIN VDE 0110/1.89)
Maximum Working Insulation Voltage
Input to Output Test Voltage, Method b*
Input to Output Test Voltage, Method a*
Highest Allowable Overvoltage*
(Transient Overvoltage, t
Safety Limiting Values
Insulation Resistance at T
Notes:
*
1. Isolation characteristics are guaranteed only within the safety maximum ratings which must be ensured by protective circuits in application.
5
for rated mains voltage ≤ 150 V rms
for rated mains voltage ≤ 300 V rms
for rated mains voltage ≤ 450 V rms
for rated mains voltage ≤ 600 V rms
for rated mains voltage ≤ 1000 V rms
V
with t
V
t
Case Temperature
Input Current
Output Power
Refer to the front of the optocoupler section of the current catalog, under Product Safety Regulations section IEC/EN/DIN EN 60747-5-2, for a
detailed description.
m
IORM
IORM
= 60 sec, Partial Discharge < 5 pC
m
x 1.875 = V
x 1.5 = V
= 1 sec, Partial Discharge < 5 pC
60
PR
, Type and Sample Test,
PR
- - Insulation elated Characteristics
, 100% Production Test
ini
S
, V
= 10 sec)
IO
= 500 V
Symbol
L (101)
L (102)
CTI
Stretched
S -6 and S -
8
8
0.08
175
IIIa
alue
Symbol
V
V
V
V
T
I
P
R
S,INPUT
S
IORM
PR
PR
IOTM
S,OUTPUT
S
mm
mm
mm
Volts
nits
Conditions
Measured from input terminals to output
terminals, shortest distance through air.
Measured from input terminals to output
terminals, shortest distance path along body.
Through insulation distance, conductor to
conductor, usually the direct distance
between the photoemitter and photodetector
inside the optocoupler cavity.
DIN IEC 112/VDE 0303 Part 1
Material Group (DIN VDE 0110, 1/89, Table 1)
Stretched S0-6 & S - alue
I-IV
I-III
I-III
I-III
I-II
55/85/21
2
1140
2137
1710
8000
175
230
600
≥ 10
9
V
V
V
V
˚C
mA
mW
Ω
nits
peak
peak
peak
peak

Related parts for ACPL-K63L-500E