Specifications of HCPL-070A#060

Input Type
DC
Package / Case
8-SOIC (0.154", 3.90mm Width)
Voltage - Isolation
3750Vrms
Number Of Channels
1, Unidirectional
Current - Output / Channel
60mA
Data Rate
100KBd
Propagation Delay High - Low @ If
65µs @ 40µA
Current - Dc Forward (if)
5mA
Output Type
Open Collector
Mounting Type
Surface Mount
Isolation Voltage
3750 Vrms
Minimum Forward Diode Voltage
1.1 V
Output Device
Photodarlington
Configuration
1 Channel
Current Transfer Ratio
25000 %
Maximum Baud Rate
100 KBps
Maximum Forward Diode Voltage
1.4 V
Maximum Reverse Diode Voltage
2.5 V
Maximum Input Diode Current
5 mA
Maximum Power Dissipation
115 mW
Maximum Operating Temperature
+ 85 C
Minimum Operating Temperature
- 40 C
Lead Free Status / RoHS Status
Contains lead / RoHS non-compliant

Available stocks

Company
Part Number
Manufacturer
Quantity
Price
Company:
Part Number:
HCPL-070A#060HCPL-070A
Manufacturer:
AVAGO/安华高
Quantity:
20 000
Company:
Part Number:
HCPL-070A#060HCPL-070A#500
Manufacturer:
AGILENT
Quantity:
5 510
Company:
Part Number:
HCPL-070A#060HCPL-070A#500
Manufacturer:
SIEMENS
Quantity:
5 510
Company:
Part Number:
HCPL-070A#060HCPL-070A-000E
Manufacturer:
AVAGO
Quantity:
10 000
Company:
Part Number:
HCPL-070A#060HCPL-070A-000E
Manufacturer:
AVAGO/安华高
Quantity:
20 000
8
IEC/EN/DIN EN 60747-5-2
*Refer to the front of the optocoupler section of the current catalog, under Product Safety Regulations section, IEC/EN/DIN EN
60747-5-2, for a detailed description.
Note: Isolation characteristics are guaranteed only within the safety maximum ratings which must be ensured by protective circuits in
application.
Installation classification per DIN VDE 0110/1.89, Table 1
Climatic Classification
Pollution Degree (DIN VDE 0110/1.89)
Maximum Working Insulation Voltage
Input to Output Test Voltage, Method b*
Input to Output Test Voltage, Method a*
Highest Allowable Overvoltage*
(Transient Overvoltage, t
Safety Limiting Values
Insulation Resistance at T
for rated mains voltage
for rated mains voltage
V
Partial Discharge < 5 pC
V
t
(Maximum values allowed in the event of a failure,
also see Figure 16, Thermal Derating curve.)
m
IORM
IORM
Case Temperature
Input Current
Output Power
= 60 sec, Partial Discharge < 5 pC
x 1.87 = V
x 1.5 = V
PR
PR
, Type and sample test,
, 100% Production Test with t
Description
ini
S
, V
= 10 sec)
Insulation Related Characteristics
300 V rms
450 V rms
IO
= 500 V
m
= 1 sec,
P
Symbol
I
S,OUTPUT
(HCPL-4701 OPTION 060 ONLY)
V
V
S,INPUT
V
V
IORM
IOTM
T
R
PR
PR
S
S
Characteristic
55/85/21
1181
6000
>10
630
945
175
230
600
I-IV
I-III
2
9
Units
V
V
V
V
mW
mA
peak
peak
peak
peak
C