6N139 Avago Technologies US Inc., 6N139 Datasheet - Page 12

OPTOCOUPLER DARL-OUT 8-DIP

6N139

Manufacturer Part Number
6N139
Description
OPTOCOUPLER DARL-OUT 8-DIP
Manufacturer
Avago Technologies US Inc.
Datasheet

Specifications of 6N139

Voltage - Isolation
3750Vrms
Number Of Channels
1, Unidirectional
Current - Output / Channel
60mA
Data Rate
100KBd
Propagation Delay High - Low @ If
5µs @ 500µA
Current - Dc Forward (if)
20mA
Input Type
DC
Output Type
Open Collector
Mounting Type
Through Hole
Package / Case
8-DIP (0.300", 7.62mm)
No. Of Channels
1
Isolation Voltage
3.75kV
Optocoupler Output Type
Photodarlington
Input Current
12mA
Output Voltage
18V
Opto Case Style
DIP
No. Of Pins
8
Ctr Max
5000%
Propagation Delay Low-high
115µs
Lead Free Status / RoHS Status
Contains lead / RoHS non-compliant
Other names
516-1009-5

Available stocks

Company
Part Number
Manufacturer
Quantity
Price
Part Number:
6N139
Manufacturer:
FSC
Quantity:
13 743
Part Number:
6N139
Manufacturer:
INFINEON
Quantity:
6 500
Part Number:
6N139
Manufacturer:
XILINX
0
Part Number:
6N139
Manufacturer:
FAIRCHILD/仙童
Quantity:
20 000
Company:
Part Number:
6N139
Quantity:
17 000
Part Number:
6N139#320
Manufacturer:
Agilent
Quantity:
3 200
Part Number:
6N139#320
Manufacturer:
AGILENT
Quantity:
20 000
Part Number:
6N139(DIP)
Manufacturer:
FAIRCHILD
Quantity:
190
Part Number:
6N139-000E
Manufacturer:
AVG
Quantity:
4 684
Part Number:
6N139-000E
Manufacturer:
AVAGO/安华高
Quantity:
20 000
Part Number:
6N139-020E
Manufacturer:
AVAGO/安华高
Quantity:
20 000
Part Number:
6N139-300E
Manufacturer:
AVAGO/安华高
Quantity:
20 000
Company:
Part Number:
6N139-560E
Quantity:
6 000
Notes:
1. DC CURRENT TRANSFER RATI0
2. Pin 7 Open.
3. Device considered a two-terminal
4. Use of a resistor between pin 5 and 7
5. Common mode transient immunity in a
Package Characteristics
**All typicals at T
†The Input-Output Momentary Withstand Voltage is a dielectric voltage rating that should not be interpreted as an input-output
continuous voltage rating. For the continuous voltage rating refer to the IEC/EN/DIN EN 60747-5-2 Insulation Characteristics Table (if
applicable), your equipment level safety specification or Agilent Application Note 1074 entitled “Optocoupler Input-Output Endurance
Voltage.”
(CTR) is defined as the ratio of output
collector current, I
LED input current, I
device. Pins 1, 2, 3, and 4 shorted
together and Pins 5, 6, 7, and 8 shorted
together.
will decrease gain and delay time.
Significant reduction in overall gain can
occur when using resistor values below
47 k . For more information, please
contact your local HP Components
representative.
Logic High level is the maximum toler-
Input-Output Momentary
Withstand Voltage†
Resistance (Input-Output)
Capacitance (Input-Output)
Parameter
A
= 25 C, unless otherwise noted.
Option 020
HCNW139
HCNW138
O
, to the forward
F
, times 100%.
Sym.
V
R
C
ISO
I-O
I-O
6. In applications where dV/dt may exceed
7. Use of a 0.1 F bypass capacitor
able (positive) dV
mode pulse, V
output will remain in a Logic High state
(i.e., V
transient immunity in a Logic Low level
is the maximum tolerable (negative)
dV
V
remain in a Logic Low state (i.e.,
V
50,000 V/ s (such as static discharge) a
series resistor, R
to protect the detector IC from
destructively high surge currents. The
recommended value is R
connected between pins 8 and 5
adjacent to the device is recommended.
5000
CM
O
Min. Typ.** Max. Units
3750
CM
< 0.8 V).
, to assure that the output will
/dt of the common mode pulse,
O
> 2.0 V). Common mode
10
0.6
CM
12
, to assure that the
CC
CM
, should be included
/dt of the common
CC
= 220 .
V rms
pF
RH < 50%, t = 1 min.,
T
V
RH < 45%
f = 1 MHz
A
I-O
Test Conditions
= 25 C
8. In accordance with UL 1577, each
9. In accordance with UL 1577, each
12
= 500 Vdc
optocoupler is proof tested by applying
an insulation test voltage 4500 V rms
for 1 second (leakage detection current
limit, I
formed before the 100% production test
shown in the IEC/EN/DIN EN
60747-5-2 Insulation Related
Characteristics Table, if applicable.
optocoupler is proof tested by applying
an insulation test voltage > 6000 V rms
for 1 second (leakage detection current
limit, I
formed before the 100% production test
for partial discharge (method b) shown
in the IEC/EN/DIN EN 60747-5-2
Insulation Related Characteristics Table,
if applicable.
I-O
I-O
< 5 A). This test is per-
< 5 A). This test is per-
Fig. Note
3, 8
3, 9
3
3

Related parts for 6N139