HCNW139-300E Avago Technologies US Inc., HCNW139-300E Datasheet - Page 8

OPTOCOUPLER DARL-OUT GW 8-SMD W

HCNW139-300E

Manufacturer Part Number
HCNW139-300E
Description
OPTOCOUPLER DARL-OUT GW 8-SMD W
Manufacturer
Avago Technologies US Inc.
Datasheets

Specifications of HCNW139-300E

Input Type
DC
Package / Case
8-SMD (400 mil) Gull Wing
Voltage - Isolation
3750Vrms
Number Of Channels
1, Unidirectional
Current - Output / Channel
60mA
Data Rate
100KBd
Propagation Delay High - Low @ If
5µs @ 500µA
Current - Dc Forward (if)
25mA
Output Type
Open Collector
Mounting Type
Surface Mount, Gull Wing
Isolation Voltage
5000 Vrms
Maximum Continuous Output Current
60 mA
Maximum Forward Diode Current
20 mA
Minimum Forward Diode Voltage
1.25 V
Output Device
Darlington With Base
Configuration
1 Channel
Current Transfer Ratio
4500 %(Typ)
Maximum Baud Rate
100 KBps
Maximum Forward Diode Voltage
1.85 V
Maximum Reverse Diode Voltage
3 V
Maximum Input Diode Current
20 mA
Maximum Power Dissipation
135 mW
Maximum Operating Temperature
+ 70 C
Minimum Operating Temperature
0 C
No. Of Channels
1
Optocoupler Output Type
Photodarlington
Input Current
12mA
Output Voltage
18V
Opto Case Style
SMD
No. Of Pins
8
Ctr Min
1500%
Forward Voltage
1.4V
Rohs Compliant
Yes
Data Rate Max
100Kbps
Lead Free Status / RoHS Status
Lead free / RoHS Compliant
Lead Free Status / RoHS Status
Lead free / RoHS Compliant, Lead free / RoHS Compliant
Other names
516-1613-5

Available stocks

Company
Part Number
Manufacturer
Quantity
Price
Part Number:
HCNW139-300E
Manufacturer:
AVAGO
Quantity:
4 100
Part Number:
HCNW139-300E
Manufacturer:
AVAGO/安华高
Quantity:
20 000
IEC/EN/DIN EN 60747-5-2 Insulation Related Characteristics (HCNW139 and HCNW138)
*Refer to the front of the optocoupler section of the current catalog, under Product Safety Regulations section, IEC/EN/DIN EN 60747-5-2, for a
detailed description.
Note: Isolation characteristics are guaranteed only within the safety maximum ratings which must be ensured by protective circuits in applica-
tion.
8
Description
Installation Classification per DIN VDE 0110/1.89, Table 1
Climatic Classification
Pollution Degree (DIN VDE 0110/1.89)
Maximum Working Insulation Voltage
Input to Output Test Voltage, Method b*
Input to Output Test Voltage, Method a*
Highest Allowable Overvoltage*
(Transient Overvoltage, t
Safety Limiting Values
Insulation Resistance at T
for rated mains voltage ≤600 V rms
for rated mains voltage ≤1000 V rms
V
Partial Discharge < 5 pC
V
t
(Maximum values allowed in the event of a failure,
also see Figure 11, Thermal Derating curve.)
P
PR
PR
= 60 sec, Partial Discharge < 5 pC
Case Temperature
Current (Input Current I
Output Power
= 1.875 x V
= 1.5 x V
IORM
IORM
, Type and Sample Test,
, 100% Production Test with t
ini
S
, V
= 10 sec)
IO
F
, P
= 500 V
S
= 0)
P
= 1 sec,
P
Symbol
I
V
S,OUTPUT
V
S,INPUT
V
V
IORM
R
IOTM
T
PR
PR
S
S
Characteristic
55/100/21
> 10
1414
2652
2121
8000
175
400
700
I-III
I-IV
2
9
Units
V
V
V
V
mW
mA
°C
Ω
peak
peak
peak
peak