ADUM3300ARWZ Analog Devices Inc, ADUM3300ARWZ Datasheet - Page 19

no-image

ADUM3300ARWZ

Manufacturer Part Number
ADUM3300ARWZ
Description
IC DIGITAL ISOLATOR 3CH 16-SOIC
Manufacturer
Analog Devices Inc
Series
iCoupler®r
Datasheet

Specifications of ADUM3300ARWZ

Propagation Delay
65ns
Inputs - Side 1/side 2
3/0
Number Of Channels
3
Isolation Rating
2500Vrms
Voltage - Supply
2.7 V ~ 5.5 V
Data Rate
1Mbps
Output Type
Logic
Package / Case
16-SOIC (0.300", 7.5mm Width)
Operating Temperature
-40°C ~ 105°C
No. Of Channels
3
Supply Current
2.4mA
Supply Voltage Range
2.7V To 5.5V
Digital Ic Case Style
SOIC
No. Of Pins
16
Operating Temperature Range
-40°C To +105°C
Lead Free Status / RoHS Status
Lead free / RoHS Compliant

Available stocks

Company
Part Number
Manufacturer
Quantity
Price
Part Number:
ADUM3300ARWZ
Manufacturer:
AD
Quantity:
1
Part Number:
ADUM3300ARWZ
Manufacturer:
ADI/亚德诺
Quantity:
20 000
INSULATION LIFETIME
All insulation structures eventually break down when subjected
to voltage stress over a sufficiently long period. The rate of
insulation degradation is dependant on the characteristics of
the voltage waveform applied across the insulation. In addition
to the testing performed by the regulatory agencies, Analog
Devices executes an extensive set of evaluations to determine
the lifetime of the insulation structure within the ADuM330x.
Analog Devices performs accelerated life testing using voltage
levels higher than the rated continuous working voltage.
Acceleration factors for several operating conditions are
determined. These factors allow calculation of the time to
failure at the actual working voltage.
The values shown in Table 10 summarize the peak voltage for
50 years of service life for a bipolar ac operating condition, and
the maximum CSA/VDE approved working voltages. In many
cases, the approved working voltage is higher than 50-year
service life voltage. Operation at these high working voltages
can lead to shortened insulation life.
The insulation lifetime of the ADuM330x depends on the
voltage waveform type imposed across the isolation barrier.
The iCoupler insulation structure degrades at different rates
depending on whether the waveform is bipolar ac, unipolar ac,
or dc. Figure 18, Figure 19, and Figure 20 illustrate these
different isolation voltage waveforms.
Bipolar ac voltage is the most stringent environment. The goal
of a 50-year operating lifetime under the ac bipolar condition
determines the Analog Devices recommended maximum
working voltage.
In the case of unipolar ac or dc voltage, the stress on the
insulation is significantly lower. This allows operation at higher
working voltages while still achieving a 50-year service life. The
Rev. A | Page 19 of 20
working voltages listed in Table 10 can be applied while
maintaining the 50-year minimum lifetime, provided that the
voltage conforms to either the unipolar ac or dc voltage cases.
Any cross-insulation voltage waveform that does not conform
to Figure 19 or Figure 20 should be treated as a bipolar ac
waveform, and its peak voltage should be limited to the 50 year
lifetime voltage value listed in Table 10.
Note that the voltage presented in Figure 19 is shown as
sinusoidal for illustration purposes only. It is meant to represent
any voltage waveform varying between 0 V and some limiting
value. The limiting value can be positive or negative, but the
voltage cannot cross 0 V.
RATED PEAK VOLTAGE
RATED PEAK VOLTAGE
RATED PEAK VOLTAGE
0V
0V
0V
Figure 19. Unipolar AC Waveform
Figure 18. Bipolar AC Waveform
Figure 20. DC Waveform
ADuM3300/ADuM3301