X60003CIG3-50T1 Intersil, X60003CIG3-50T1 Datasheet - Page 5

no-image

X60003CIG3-50T1

Manufacturer Part Number
X60003CIG3-50T1
Description
IC PREC V-REF 5V 20PPM SOT-23
Manufacturer
Intersil
Series
FGA™r
Datasheet

Specifications of X60003CIG3-50T1

Reference Type
Series
Voltage - Output
5V
Tolerance
±2.5mV
Temperature Coefficient
20ppm/°C
Voltage - Input
5.1 ~ 9 V
Number Of Channels
1
Current - Quiescent
900nA
Current - Output
10mA
Operating Temperature
-40°C ~ 85°C
Mounting Type
Surface Mount
Package / Case
SOT-23-3, TO-236-3, Micro3™, SSD3, SST3
Lead Free Status / RoHS Status
Contains lead / RoHS non-compliant
Current - Cathode
-
Electrical Specifications(X60003-50)
NOTES:
10. Long term drift is logarithmic in nature and diminishes over time. Drift after the first 1000 hours will be approximately
11. Parameters with MIN and/or MAX limits are 100% tested at +25°C, unless otherwise specified. Temperature limits established
8. Over the specified temperature range. Temperature coefficient is measured by the box method whereby the change in V
9. Thermal Hysteresis is the change of V
ΔV
ΔV
ΔV
SYMBOL
ΔV
divided by the temperature range; in this case, -40°C to +85°C = +125°C.
is read initially at T
is taken at +25°C. The difference between the initial V
For Δ T
10ppm/sqrt(1kHrs).
by characterization and are not production tested.
OUT
OUT
OUT
V
V
OUT
V
OUT
DO
IN
/ΔI
/ΔV
/ΔT
/Δt
A
OUT
IN
A
= +125°C, the device under test is cycled from +25°C to +85°C to -40°C to +85°C.
Input Voltage Range
Output Voltage
Line Regulation
Load Regulation
Dropout Voltage
Thermal Hysteresis (Note 9)
Long Term Stability (Note 10)
A
= +25°C for the device under test. The device is temperature cycled and a second V
PARAMETER
5
OUT
measured at T
+5.5V ≤ V
Sourcing: 0mA≤ I
Sinking: -10mA ≤ I
I
ΔT = -40°C to +85°C
T
OUT
A
= +25°C
limits apply over the operating temperature range, -40°C to
+85°C.
V
= 5mA, ΔV
IN
= 6.5V, T
X60003
OUT
A
IN
CONDITIONS
= +25°C after temperature cycling over a specified range, ΔT
≤ +8.0V
reading and the second V
OUT
SOURCE
A
SINK
= -40°C to +85°C, unless otherwise specified. Boldface
= -0.01%
≤ 0mA
≤ 10mA
(Note 11)
OUT
MIN
5.1
reading is then expressed in ppm.
5.000
TYP
150
100
10
20
45
(Note 11) UNITS
OUT
MAX
150
100
300
9.0
50
measurement
March 21, 2011
µV/mA
µV/mA
A
FN8137.3
µV/V
ppm
ppm
. V
OUT
mV
V
V
OUT
is

Related parts for X60003CIG3-50T1