MAX1989MUE+ Maxim Integrated Products, MAX1989MUE+ Datasheet - Page 4

IC TEMP SENSOR REMOTE 16TSSOP

MAX1989MUE+

Manufacturer Part Number
MAX1989MUE+
Description
IC TEMP SENSOR REMOTE 16TSSOP
Manufacturer
Maxim Integrated Products
Datasheet

Specifications of MAX1989MUE+

Function
Thermometer, Thermostat
Topology
ADC, Comparator, Multiplexer, Register Bank
Sensor Type
External & Internal
Sensing Temperature
-55°C ~ 125°C, External Sensor
Output Type
I²C™/SMBus™
Output Alarm
Yes
Output Fan
No
Voltage - Supply
3 V ~ 5.5 V
Operating Temperature
-55°C ~ 125°C
Mounting Type
Surface Mount
Package / Case
16-TSSOP
Full Temp Accuracy
+/- 3.5 C, +/- 5 C
Digital Output - Bus Interface
Serial (2-Wire)
Digital Output - Number Of Bits
7 bit + Sign
Maximum Operating Temperature
+ 125 C
Minimum Operating Temperature
- 55 C
Case
TSSOP
Dc
06+
Lead Free Status / RoHS Status
Lead free / RoHS Compliant
Multichannel Remote/Local
Temperature Sensors
ELECTRICAL CHARACTERISTICS (continued)
(V
(Typical Operating Circuit, V
4
Note 1: Guaranteed by design, but not production tested.
Note 2: Quantization error is not included in specifications for temperature accuracy. For example, if the MAX1668/MAX1805/
Note 3: A remote diode is any diode-connected transistor from Table 1. T
Note 4: The SMBus logic block is a static design that works with clock frequencies down to DC. While slow operation is possible, it
Note 5: Note that a transition must internally provide at least a hold time in order to bridge the undefined region (300ns max) of
Note 6: Specifications from -55°C to +125°C are guaranteed by design, not production tested.
Logic Input High Voltage
Logic Input Low Voltage
Logic Output Low Sink Current
ALERT Output High Leakage
Current
Logic Input Current
SMBus INTERFACE
CC
-10
-20
20
10
_______________________________________________________________________________________
0
= +5V, STBY = V
1
Remote-Diode Selection section for remote-diode forward-voltage requirements.
violates the 10kHz minimum clock frequency and SMBus specifications, and can monopolize the bus.
SMBCLK’s falling edge t
MAX1989 device temperature is exactly +66.7°C, the ADC may report +66°C, +67°C, or +68°C (due to the quantization
error plus the +0.5°C offset used for rounding up) and still be within the guaranteed ±1°C error limits for the +60°C to
+100°C temperature range. See Table 2.
PARAMETER
vs. PC BOARD RESISTANCE
TEMPERATURE ERROR
LEAKAGE RESISTANCE (MΩ)
CC
PATH = DXP_ TO V
10
PATH = DXP_ TO GND
, configuration byte = X0XXXX00, T
CC
= +5V, STBY = V
HD:DAT.
CC
(5V)
STBY, SMBCLK, SMBDATA; V
STBY, SMBCLK, SMBDATA; V
ALERT, SMBDATA forced to 0.4V
ALERT forced to 5.5V
Logic inputs forced to V
100
CC
-1
-2
4
3
2
1
0
, configuration byte = X0XXXX00, T
-50
-30
NPN (CMPT3904)
INTERNAL
-10
CONDITIONS
TEMPERATURE ERROR
A
vs. TEMPERATURE
= -55°C to +125°C, unless otherwise noted.) (Note 6)
TEMPERATURE (°C)
CC
PNP (CMPT3906)
10
or GND
30
CC
CC
Typical Operating Characteristics
50
= 4.5V to 5.5V
= 4.5V to 5.5V
R
70
is the junction temperature of the remote diode. See the
90
110
A
= +25°C, unless otherwise noted.)
24
20
16
12
8
4
0
0.1
MIN
2.4
WITH V
2200pF BETWEEN DXN_ AND DXP_
-2
6
vs. SUPPLY NOISE FREQUENCY
CC
TEMPERATURE ERROR
0.1µF CAPACITOR REMOVED
TYP
FREQUENCY (MHz)
1
250mV
MAX
0.8
+2
1
10
P-P
100mV
UNITS
mA
µA
µA
P-P
V
V
100