Specifications of DS1624

Function
Thermometer, Thermostat
Topology
EEPROM, Register Bank
Sensor Type
Internal
Sensing Temperature
-55°C ~ 125°C
Output Type
2-Wire Serial
Output Alarm
No
Output Fan
No
Voltage - Supply
2.7 V ~ 5.5 V
Operating Temperature
-55°C ~ 125°C
Mounting Type
Through Hole
Package / Case
8-DIP (0.300", 7.62mm)
Full Temp Accuracy
+/- 0.5 C
Digital Output - Bus Interface
Serial (2-Wire)
Digital Output - Number Of Bits
13 bit
Maximum Operating Temperature
+ 125 C
Minimum Operating Temperature
- 55 C
Lead Free Status / RoHS Status
Contains lead / RoHS non-compliant

Available stocks

Company
Part Number
Manufacturer
Quantity
Price
Part Number:
DS1624
Manufacturer:
DALLAS
Quantity:
5 510
Part Number:
DS1624
Manufacturer:
FUJ
Quantity:
5 510
Part Number:
DS1624+
Manufacturer:
MAXIM
Quantity:
2 000
Part Number:
DS16245
Manufacturer:
DALLAS
Quantity:
5 510
Part Number:
DS16245
Manufacturer:
SIEMENS
Quantity:
5 510
Part Number:
DS1624S
Manufacturer:
DALLAS
Quantity:
20 000
Part Number:
DS1624S+
Manufacturer:
MAIXM
Quantity:
20 000
Part Number:
DS1624S+TR
Manufacturer:
MAXIM/美信
Quantity:
20 000
AC ELECTRICAL CHARACTERISTICS
PARAMETER
Input Capacitance
NOTES:
1. All voltages are referenced to ground.
2. I/O pins of fast mode devices must not obstruct the SDA and SCL lines if V
3. I
4. I
5. After this period, the first clock pulse is generated.
6. The maximum t
7. A fast mode device can be used in a standard mode system, but the requirement t
8. C
9. Writing to the nonvolatile memory should only take place in the 0°C to 70°C temperature range.
10. See Typical Curve for specification limits outside the 0°C to 70°C temperature range. Thermometer
SCL signal.
then be met. This will automatically be the case if the device does not stretch the LOW period of the
SCL signal. If such a device does stretch the LOW period of the SCL signal, it must output the next
data bit to the SDA line t
error reflects sensor accuracy as tested during calibration.
CC
CC
b
– total capacitance of one bus line in pF.
specified with SDA pin open.
specified with V
HD:DAT
CC
at 5.0V and SDA, SCL = 5.0V, 0°C to 70°C.
has only to be met if the device does not stretch the LOW period (t
RMAX
+t
SU:DAT
SYMBOL
= 1000+250 = 1250 ns before the SCL line is released.
C
I
16 of 17
MIN
(-55°C to +125°C; V
TYP
5
MAX
DD
is switched off.
DD
UNITS
SU:DAT
=2.7V to 5.5V)
pF
>250 ns must
LOW
NOTES
) of the
DS1624

Related parts for DS1624