MAX6680MEE+T Maxim Integrated Products, MAX6680MEE+T Datasheet - Page 3

IC TEMP SENSOR SMBUS 16-QSOP

MAX6680MEE+T

Manufacturer Part Number
MAX6680MEE+T
Description
IC TEMP SENSOR SMBUS 16-QSOP
Manufacturer
Maxim Integrated Products
Datasheet

Specifications of MAX6680MEE+T

Function
Thermometer, Thermostat
Topology
ADC, Multiplexer, Register Bank
Sensor Type
External & Internal
Sensing Temperature
-55°C ~ 125°C, External Sensor
Output Type
I²C™/SMBus™
Output Alarm
Yes
Output Fan
Yes
Voltage - Supply
3 V ~ 5.5 V
Operating Temperature
-55°C ~ 125°C
Mounting Type
Surface Mount
Package / Case
16-QSOP
Full Temp Accuracy
+/- 5 C, +/- 3 C
Digital Output - Bus Interface
Serial (2-Wire)
Digital Output - Number Of Bits
10 bit + Sign
Maximum Operating Temperature
+ 125 C
Minimum Operating Temperature
- 55 C
Lead Free Status / RoHS Status
Lead free / RoHS Compliant
ELECTRICAL CHARACTERISTICS (continued)
(Circuit of Typical Operating Circuit, V
= 3.3V and T
Note 1: T
Note 2: If both the local and the remote junction are below T
Note 3: Conversions done in extended mode. For legacy mode, current is approximately half.
Note 4: Timing specifications guaranteed by design.
Note 5: The serial interface resets when SMBCLK or SMBDATA is low for more than t
Note 6: A transition must internally provide at least a hold time to bridge the undefined region (300ns max) of SMBCLK’s falling edge.
CRIT0, CRIT1, ADD0, ADD1, RESET, INT_SEL, SENS_SEL
Logic Input Low Voltage
Logic Input High Voltage
Input Leakage Current
(ALERT, OVERT)
SMBus INTERFACE (SMBCLK, SMBDATA, STBY)
SMBus-COMPATIBLE TIMING (Note 5)
Output Low Sink Current
Output High Leakage Current
Logic Input Low Voltage
Logic Input High Voltage
Input Leakage Current
Output Low Sink Current
Input Capacitance
Serial Clock Frequency (Note 5)
Bus Free Time Between STOP
and START Condition
START Condition Setup Time
Repeat START Condition Setup
Time
START Condition Hold Time
STOP Condition Setup Time
Clock Low Period
Clock High Period
Data Setup Time (Note 6)
Receive SCL/SDA Rise Time
Receive SCL/SDA Fall Time
Pulse Width of Spike Suppressed
SMBus Timeout (Note 5)
PARAMETER
A
= +25°C to +85°C.
A
= +25°C.)
±1°C Fail-Safe Remote/Local Temperature
_______________________________________________________________________________________
SYMBOL
CC
t
t
t
t
HD:STA
SU:STO
HD:DAT
SU:STA
I
I
t
t
t
LEAK
LEAK
f
HIGH
C
LOW
V
V
I
BUF
V
V
SCL
t
OL
t
t
SP
= 3.0V to 5.5V, T
R
IH
IH
F
IL
IL
IN
V
V
V
V
V
V
90% to 90%
10% of SMBDATA to 90% of SMBCLK
90% of SMDCLK to 90% of SMBDATA
10% to 10%
90% to 90%
SMBDATA low period for interface reset
Sensors with SMBus Interface
OL
OH
CC
CC
IN
OL
= GND or V
= 0.4V
= 0.6V
= 3.0V
= 5.5V
= 5.5V
A
= -25°C to +125°C, unless otherwise specified. Typical values are at V
A
= -20°C, then V
CC
CONDITIONS
CC
> 3.15V.
TIMEOUT
.
MIN
250
2.4
2.2
2.4
4.7
4.7
50
25
-1
4
4
4
0
TYP
4.7
37
5
MAX
100
300
0.8
0.8
+1
±2
50
45
1
1
6
1
UNITS
kHz
mA
mA
ms
µA
µA
µA
pF
µs
µs
ns
µs
µs
µs
µs
ns
µs
ns
ns
V
V
V
V
CC
3

Related parts for MAX6680MEE+T