Datasheet

Specifications of MAX6692MSA+

Function
Temp Monitoring System (Sensor)
Topology
ADC, Multiplexer, Register Bank
Sensor Type
External & Internal
Sensing Temperature
0°C ~ 125°C, External Sensor
Output Type
I²C™/SMBus™
Output Alarm
Yes
Output Fan
Yes
Voltage - Supply
3 V ~ 5.5 V
Operating Temperature
-55°C ~ 125°C
Mounting Type
Surface Mount
Package / Case
8-SOIC (3.9mm Width)
Full Temp Accuracy
+/- 3 C
Digital Output - Bus Interface
Serial (2-Wire)
Digital Output - Number Of Bits
10 bit + Sign
Maximum Operating Temperature
+ 125 C
Minimum Operating Temperature
0 C
Lead Free Status / RoHS Status
Lead free / RoHS Compliant
Temperature Sensors with Overtemperature Alarms
The MAX6648/MAX6692 are temperature sensors
designed to work in conjunction with a microprocessor
or other intelligence in thermostatic, process-control, or
monitoring applications. Communication with the
MAX6648/MAX6692 occurs through the SMBus-com-
patible serial interface and dedicated alert pins. ALERT
asserts if the measured local or remote temperature is
greater than the software-programmed ALERT high
limit or less than the ALERT low limit. ALERT also
asserts if the remote-sensing diode pins are shorted or
unconnected. The overtemperature alarm, OVERT,
asserts if the software-programmed OVERT limit is
exceeded. OVERT can be connected to fans, a system
shutdown, a clock throttle control, or other thermal-
management circuitry.
The MAX6648/MAX6692 convert temperatures to digital
data either at a programmed rate or in single conver-
sions. Temperature data is represented as 10 bits plus
sign, with the LSB equal to 0.125°C. The “main” tempera-
ture data registers (at addresses 00h and 01h) are 8-bit
registers that represent the data as 7 bits with the final
MSB indicating the diode fault status (Table 1). The
remaining 3 bits of temperature data are available in the
“extended” registers at addresses 11h and 10h (Table 2).
PIN
1
2
3
4
5
6
7
8
Precision SMBus-Compatible Remote/Local
_ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _
OVERT
ALERT
NAME
SCLK
GND
DXN
SDA
V
DXP
CC
Detailed Description
Supply Voltage Input, 3V to 5.5V. Bypass V
resistor is recommended but not required for additional noise filtering.
Combined Remote-Diode Current Source and A/D Positive Input for Remote-Diode Channel. DO
NOT LEAVE DXP DISCONNECTED; connect DXP to DXN if no remote diode is used. Place a
2200pF capacitor between DXP and DXN for noise filtering.
Combined Remote-Diode Current Sink and A/D Negative Input. DXN is internally biased to one
diode drop above ground.
Overtemperature Alert/Interrupt Output, Open Drain. OVERT is logic low when the temperature is
above the software-programmed threshold.
Ground
SMBus Alert (Interrupt) Output, Open Drain. ALERT asserts when temperature exceeds user-set
limits (high or low temperature). ALERT stays asserted until acknowledged by either reading the
status register or by successfully responding to an alert response address, provided that the fault
condition no longer exists. See the ALERT Interrupts section.
SMBus Serial-Data Input/Output, Open Drain
SMBus Serial-Clock Input
The averaging ADC integrates over a 60ms period
(each channel, typically), with excellent noise rejection.
The multiplexer automatically steers bias currents
through the remote and local diodes. The ADC and
associated circuitry measure each diode’s forward volt-
age and compute the temperature based on this volt-
age. Both channels are automatically converted once
the conversion process has started, either in free-run-
ning or single-shot mode. If one of the two channels is
not used, the device still performs both measurements,
and the user can ignore the results of the unused chan-
Table 1. Main Temperature Data Register
Format (00h, 01h)
CC
FUNCTION
(short or open)
to GND with a 0.1µF capacitor. A 200Ω series
TEMP (°C)
Diode fault
130
127
126
-25
<0
25
-1
0
ADC and Multiplexer
Pin Description
DIGITAL OUTPUT
0 111 1111
0 111 1111
0 111 1111
0 001 1001
0 000 0000
0 000 0000
0 000 0000
0 000 0000
1 000 0000
5