MAX6641AUB96+ Maxim Integrated Products, MAX6641AUB96+ Datasheet - Page 9

IC TEMP MONITOR SMBUS 10UMAX

MAX6641AUB96+

Manufacturer Part Number
MAX6641AUB96+
Description
IC TEMP MONITOR SMBUS 10UMAX
Manufacturer
Maxim Integrated Products
Datasheet

Specifications of MAX6641AUB96+

Function
Fan Control, Temp Monitor
Topology
ADC, PWM Generator, Tach Counter
Sensor Type
External & Internal
Sensing Temperature
-40°C ~ 125°C, External Sensor
Output Type
I²C™/SMBus™
Output Alarm
Yes
Output Fan
Yes
Voltage - Supply
3 V ~ 5.5 V
Operating Temperature
-40°C ~ 125°C
Mounting Type
Surface Mount
Package / Case
10-MSOP, Micro10™, 10-uMAX, 10-uSOP
Full Temp Accuracy
+/- 4 C
Digital Output - Bus Interface
Serial (2-Wire)
Digital Output - Number Of Bits
8 bit
Maximum Operating Temperature
+ 125 C
Minimum Operating Temperature
- 40 C
Lead Free Status / RoHS Status
Lead free / RoHS Compliant
These registers contain the 8-bit results of the tempera-
ture measurements. Register 00h contains the tempera-
ture reading of the remote diode. Register 01h contains
the ambient temperature reading. The value of the MSB
Figure 3. SMBus Read Timing Diagram
Figure 4. Block Diagram
SMBus-Compatible Temperature Monitor with
SMBDATA
SMBCLK
SMBCLK
SMBDATA
DXN
DXP
A = START CONDITION
B = MSB OF ADDRESS CLOCKED INTO SLAVE
C = LSB OF ADDRESS CLOCKED INTO SLAVE
D = R/W BIT CLOCKED INTO SLAVE
E = SLAVE PULLS SMBDATA LINE LOW
t
SU:STA
INTERFACE AND
TEMPERATURE
PROCESSING
REGISTERS
_______________________________________________________________________________________
A
BLOCK
SMBus
Temperature Registers (00h, 01h)
t
HD:STA
Automatic PWM Fan-Speed Controller
t
LOW
V
GND
CC
Register Descriptions
B
GENERATOR
t
HIGH
BLOCK
PWM
MAX6641
LOGIC
t
SU:DAT
C
F = ACKNOWLEDGE BIT CLOCKED INTO MASTER
G = MSB OF DATA CLOCKED INTO MASTER
H = LSB OF DATA CLOCKED INTO MASTER
I = MASTER PULLS DATA LINE LOW
PWMOUT
OT
D
E
F
is +128 C and the value of the LSB is +1 C. The MSB is
transmitted first. The POR state of the temperature reg-
isters is 00h.
The configuration byte register controls the timeout
conditions and various PWMOUT signals. The POR
state of the configuration byte register is 00h. See
Table 2 for configuration byte definitions.
Set the remote (03h) and local (04h) temperature thresh-
olds with these two registers. Once the temperature is
above the threshold, the OT output is asserted low (for
the temperature channels that are not masked). The POR
state of the remote OT limit register is 6Eh and the POR
state of the LOCAL OT limit register is 50h.
Read the OT status register to determine which channel
recorded an over-temperature condition. Bit D7 is high if
the fault reading occurred from the remote diode. Bit D6
is high if the fault reading occurred in the local diode.
The OT status register is cleared only by reading its con-
tents. Reading the contents of the register also makes
the OT output high impedance. If the fault is still present
on the next temperature measurement cycle, the corre-
sponding bits and the OT output are set again. After
reading the OT status register, a temperature register
read must be done to correctly clear the appropriate sta-
tus bit. The POR state of the OT status register is 00h.
t
HD:DAT
G
Remote and Local
H
J = ACKNOWLEDGE CLOCKED INTO SLAVE
K = ACKNOWLEDGE CLOCK PULSE
L = STOP CONDITION
M = NEW START CONDITION
Configuration Byte Register (02h)
I
J K
OT Limits (03h, 04h)
t
SU:STO
OT Status (05h)
L
t
BUF
M
9