MAX6695AUB+ Maxim Integrated Products, MAX6695AUB+ Datasheet - Page 10

IC SENSOR TEMP SMBUS 10-UMAX

MAX6695AUB+

Manufacturer Part Number
MAX6695AUB+
Description
IC SENSOR TEMP SMBUS 10-UMAX
Manufacturer
Maxim Integrated Products
Datasheet

Specifications of MAX6695AUB+

Function
Temp Monitoring System (Sensor)
Topology
ADC, Multiplexer, Register Bank
Sensor Type
External & Internal
Sensing Temperature
-40°C ~ 125°C, External Sensor
Output Type
I²C™/SMBus™
Output Alarm
Yes
Output Fan
Yes
Voltage - Supply
3 V ~ 3.6 V
Operating Temperature
-40°C ~ 125°C
Mounting Type
Surface Mount
Package / Case
10-MSOP, Micro10™, 10-uMAX, 10-uSOP
Full Temp Accuracy
+/- 3 C
Digital Output - Bus Interface
Serial (2-Wire)
Digital Output - Number Of Bits
10 bit + Sign
Maximum Operating Temperature
+ 125 C
Minimum Operating Temperature
- 40 C
Lead Free Status / RoHS Status
Lead free / RoHS Compliant
extended temperature register (11h) (Table 3), which
extends the temperature data to 10 bits + sign and the
resolution to +0.125°C per LSB (Table 4).
When a conversion is complete, the main register and
the extended register are updated almost simultane-
ously. Ensure that no conversions are completed
between reading the main and extended registers so
that when data that is read, both registers contain the
result of the same conversion.
To ensure valid extended data, read extended resolu-
tion temperature data using one of the following
approaches:
• Put the MAX6695/MAX6696 into standby mode by
• Put the MAX6695/MAX6696 into standby mode by
There is a continuity fault detector at DXP_ that detects
an open circuit between DXP_ and DXN, or a DXP_
short to V
exists, the external temperature register (01h) is loaded
with 1000 0000. Bit 2 (diode fault) of the status registers
is correspondingly set to 1. The ALERT output asserts
for open diode faults but not for shorted diode faults.
Immediately after power-on reset (POR), the status reg-
ister indicates that no fault is present until the end of
the first conversion. After the conversion is complete,
any diode fault is indicated in the appropriate status
register. Reading the status register clears the diode
fault bit in that register, and clears the ALERT output if
set. If the diode fault is present after the next conver-
sion, the status bit will again be set and the ALERT out-
put will assert if the fault is an open diode fault.
Six registers, WLHO, WLLM, WRHA (1 and 2), and
WRLN (1 and 2), store ALERT threshold values. WLHO
and WLLM, are for internal ALERT high-temperature
and low-temperature limits, respectively. Likewise,
WRHA and WRLN are for external channel 1 and chan-
nel 2 high-temperature and low-temperature limits,
respectively (Table 5). If either measured temperature
equals or exceeds the corresponding ALERT threshold
value, the ALERT output is asserted. The POR state of
both internal and external ALERT high-temperature limit
registers is 0100 0110 or +70°C.
Dual Remote/Local Temperature Sensors with
SMBus Serial Interface
10
setting bit 6 of the configuration register to 1. Read
the contents of the data registers. Return to run
mode by setting bit 6 to zero.
setting bit 6 of the configuration register to 1. Initiate
a one-shot conversion using Send Byte command
0Fh. When this conversion is complete, read the
contents of the temperature data registers.
______________________________________________________________________________________
CC
, GND, or DXN. If an open or short circuit
Alarm Threshold Registers
Diode Fault Alarm
Table 2. Data Format (Two’s Complement)
Table 3. Extended Resolution Register
Note: Extended resolution applies only for conversion rate
control register values of 05h or less.
Table 4. Data Format in Extended Mode
TEMP (°C)
TEMPERATURE (°C)
+130.00
+127.00
+126.5
+25.25
+0.50
-1.25
(short or open)
-55
FRACTIONAL
-1
0
TEMP (°C)
Diode fault
+130.00
+127.00
+126.00
+25.25
+0.125
+0.250
+0.375
+0.500
+0.625
+0.750
+0.875
+0.50
-55
-1
0
0
INTEGER TEMP
0 111 1111
0 111 1111
0 111 1110
0 001 1001
0 000 0000
0 000 0000
1 111 1111
1111 1111
1100 1001
EXTENDED REGISTER
DIGITAL OUTPUT
CONTENTS OF
FRACTIONAL TEMP
0 111 1111
0 111 1111
0 111 1110
0 001 1001
0 000 0001
0 000 0000
1 111 1111
1 100 1001
1 000 0000
000X XXXX
001X XXXX
010X XXXX
011X XXXX
100X XXXX
101X XXXX
110X XXXX
111X XXXX
000X XXXX
000X XXXX
100X XXXX
010X XXXX
100X XXXX
000X XXXX
000X XXXX
010X XXXX
000X XXXX