EMC1403-1-AIZL-TR SMSC, EMC1403-1-AIZL-TR Datasheet - Page 36

IC TEMP SESR TRIPLE 3.3V 10MSOP

EMC1403-1-AIZL-TR

Manufacturer Part Number
EMC1403-1-AIZL-TR
Description
IC TEMP SESR TRIPLE 3.3V 10MSOP
Manufacturer
SMSC
Datasheet

Specifications of EMC1403-1-AIZL-TR

Function
Temp Monitoring System (Sensor)
Topology
ADC (Sigma Delta), Comparator, Multiplexer, Register Bank
Sensor Type
External & Internal
Sensing Temperature
-40°C ~ 125°C, External Sensor
Output Type
SMBus™
Output Alarm
No
Output Fan
Yes
Voltage - Supply
3 V ~ 3.6 V
Operating Temperature
-40°C ~ 125°C
Mounting Type
Surface Mount
Package / Case
10-MSOP, Micro10™, 10-uMAX, 10-uSOP
Lead Free Status / RoHS Status
Lead free / RoHS Compliant
Other names
638-1068-2

Available stocks

Company
Part Number
Manufacturer
Quantity
Price
Part Number:
EMC1403-1-AIZL-TR
Manufacturer:
NSC
Quantity:
5 785
Part Number:
EMC1403-1-AIZL-TR
Manufacturer:
SMSC
Quantity:
8 000
Part Number:
EMC1403-1-AIZL-TR
Manufacturer:
SMSC
Quantity:
20 000
Company:
Part Number:
EMC1403-1-AIZL-TR
Quantity:
2 500
Company:
Part Number:
EMC1403-1-AIZL-TR
Quantity:
3 732
Revision 1.37 (01-06-10)
6.12
ADDR.
22h
R/W
R/W
The Consecutive ALERT Register determines how many times an out-of-limit error or diode fault must
be detected in consecutive measurements before the ALERT or THERM pin is asserted. Additionally,
the Consecutive ALERT Register controls the SMBus Timeout functionality.
An out-of-limit condition (i.e. HIGH, LOW, or FAULT) occurring on the same temperature channel in
consecutive measurements will increment the consecutive alert counter. The counters will also be reset
if no out-of-limit condition or diode fault condition occurs in a consecutive reading.
When the ALERT pin is configured as an interrupt, when the consecutive alert counter reaches its
programmed value, the following will occur: the STATUS bit(s) for that channel and the last error
condition(s) (i.e. E1HIGH, or E2LOW and/or E2FAULT) will be set to ‘1’, the ALERT pin will be
asserted, the consecutive alert counter will be cleared, and measurements will continue.
When the ALERT pin is configured as a comparator, the consecutive alert counter will ignore diode
fault and low limit errors and only increment if the measured temperature exceeds the High Limit.
Additionally, once the consecutive alert counter reaches the programmed limit, the ALERT pin will be
asserted, but the counter will not be reset. It will remain set until the temperature drops below the High
Limit minus the THERM Hysteresis value.
For example, if the CALRT[2:0] bits are set for 4 consecutive alerts on an EMC1403 device, the high
limits are set at 70°C, and none of the channels are masked, then the ALERT pin will be asserted after
the following four measurements:
1. Internal Diode reads 71°C and both external diodes read 69°C. Consecutive alert counter for INT
2. Both Internal Diode and External Diode 1 read 71°C and External Diode 2 reads 68°C. Consecutive
3. The External Diode 1 reads 71°C and both the Internal Diode and External Diode 2 read 69°C.
4. The Internal Diode reads 71°C and both external diodes read 71°C. Consecutive alert counter for
5. The Internal Diode reads 71°C and both the external diodes read 71°C. Consecutive alert counter
Bit 7 - TIMEOUT - Determines whether the SMBus Timeout function is enabled.
Bits 6-4 - CTHRM[2:0] - Determines the number of consecutive measurements that must exceed the
corresponding THERM Limit before the THERM pin is asserted. All temperature channels use this
value to set the respective counters. The consecutive THERM counter is incremented whenever any
measurement exceed the corresponding THERM Limit.
If the temperature drops below the THERM limit, then the counter is reset. If a number of consecutive
measurements above the THERM limit occurs, then the THERM pin is asserted low.
Consecutive ALERT Register
‘0’ (default) - The SMBus Timeout feature is disabled. The SMCLK line can be held low indefinitely
without the device resetting its SMBus protocol.
‘1’ - The SMBus Timeout feature is enabled. If the SMCLK line is held low for more than 30ms,
then the device will reset the SMBus protocol.
is incremented to 1.
alert counter for INT is incremented to 2 and for EXT1 is set to 1.
Consecutive alert counter for INT and EXT2 are cleared and EXT1 is incremented to 2.
INT is set to 1, EXT2 is set to 1, and EXT1 is incremented to 3.
for INT is incremented to 2, EXT2 is set to 2, and EXT1 is incremented to 4. The appropriate status
bits are set for EXT1 and the ALERT pin is asserted. EXT1 counter is reset to 0 and all other
counters hold the last value until the next temperature measurement.
Consecutive
REGISTER
ALERT
Table 6.13 Consecutive ALERT Register
TIME
OUT
B7
B6
DATASHEET
CTHRM[2:0]
B5
36
B4
B3
1°C Temperature Sensor with Beta Compensation
CALRT[2:0]
B2
B1
SMSC EMC1403 / EMC1404
B0
-
DEFAULT
Datasheet
70h