MAX16070ETL+ Maxim Integrated Products, MAX16070ETL+ Datasheet - Page 23

no-image

MAX16070ETL+

Manufacturer Part Number
MAX16070ETL+
Description
IC SYSTEM MANAGER 12CH 40-TQFN
Manufacturer
Maxim Integrated Products
Datasheet

Specifications of MAX16070ETL+

Applications
Power Supply Monitor
Voltage - Supply
2.8 V ~ 14 V
Current - Supply
4.5mA
Operating Temperature
-40°C ~ 85°C
Mounting Type
Surface Mount
Package / Case
40-VQFN Exposed Pad, 40-HVQFN, 40-SQFN, 40-DHVQFN
Product
Current Monitors
Operating Temperature Range
- 40 C to + 85 C
Mounting Style
SMD/SMT
Accuracy
2.5 %
Sense Voltage (max)
14 V
Supply Current (max)
14 mA
Supply Voltage (max)
14 V
Supply Voltage (min)
2.8 V
Lead Free Status / RoHS Status
Lead free / RoHS Compliant
Voltage - Input
-
Lead Free Status / Rohs Status
Lead free / RoHS Compliant
The general-purpose inputs/outputs (GPIO1 to GPIO8)
can be configured as ANY_FAULT outputs or dedicated
Fault1 and Fault2 outputs to indicate fault conditions.
These fault outputs are not masked by the critical fault
enable bits shown in Table 14. See the General-Purpose
Inputs/Outputs section for more information on configur-
ing GPIO_s as fault outputs.
Fault conditions are detected at the end of each conver-
sion. When the voltage on an input falls outside a moni-
tored threshold for one acquisition, the input multiplexer
remains on that channel and performs several succes-
sive conversions. To trigger a fault, the input must stay
Table
Table
12-Channel/8-Channel, Flash-Configurable System
REGISTER
REGISTER
ADDRESS
ADDRESS
12. Deglitch Configuration
13. Fault Flags
1Bh
1Ch
73h
74h
Managers with Nonvolatile Fault Registers
______________________________________________________________________________________
ADDRESS
BIT RANGE
FLASH
273h
274h
[0]
[1]
[2]
[3]
[4]
[5]
[6]
[7]
[0]
[1]
[2]
[3]
[4]
[5]
[6]
BIT RANGE
MON1
MON2
MON3
MON4
MON5
MON6
MON7
MON8
MON9
MON10
MON11
MON12
Overcurrent
External fault (EXTFAULT)
SMB alert
[6:5]
[6:5]
Deglitch
Overcurrent comparator deglitch time
00 = No deglitch
01 = 4ms
10 = 15ms
11 = 60ms
Voltage comparator deglitch configuration
00 = 2 cycles
01 = 4 cycles
10 = 8 cycles
11 = 16 cycles
outside the threshold for a certain number of acquisitions
as determined by the deglitch setting in r73h[6:5] and
r74h[6:5] (see Table 12).
Fault flags indicate the fault status of a particular input.
The fault flag of any monitored input in the device can be
read at any time from registers r1Bh and r1Ch, as shown
in Table 13. Clear a fault flag by writing a ‘1’ to the appro-
priate bit in the flag register. Unlike the fault signals sent
to the fault outputs, these bits are masked by the Critical
Fault Enable bits (see Table 14). The fault flag is only set
when the matching enable bit in the critical fault enable
register is also set.
DESCRIPTION
DESCRIPTION
Fault Flags
23