MAX8688ALETG+ Maxim Integrated Products, MAX8688ALETG+ Datasheet - Page 21

IC PWR SUPPLY CTRLR/MONTR 24TQFN

MAX8688ALETG+

Manufacturer Part Number
MAX8688ALETG+
Description
IC PWR SUPPLY CTRLR/MONTR 24TQFN
Manufacturer
Maxim Integrated Products
Datasheet

Specifications of MAX8688ALETG+

Applications
Power Supply Controller/Monitor
Voltage - Supply
3 V ~ 3.6 V
Current - Supply
6.7mA
Operating Temperature
-40°C ~ 85°C
Mounting Type
Surface Mount
Package / Case
24-TQFN Exposed Pad
Supply Voltage (max)
3.6 V
Supply Voltage (min)
3 V
Operating Temperature Range
- 40 C to + 85 C
Mounting Style
SMD/SMT
Lead Free Status / RoHS Status
Lead free / RoHS Compliant
Voltage - Input
-
Lead Free Status / Rohs Status
Lead free / RoHS Compliant
From a software perspective, the MAX8688 appears as a
PMBus device capable of executing a subset of PMBus
commands. A PMBus 1.0-compliant device uses the
SMBus version 1.1 for transport protocol and responds
to the SMBus slave address. In this data sheet, the term
SMBus is used to refer to the electrical characteristics of
the PMBus communication using the SMBus physical
layer. The term PMBus is used to refer to the PMBus
command protocol.
The MAX8688 employs five standard SMBus protocols
(Write Word, Read Word, Write Byte, Read Byte and Send
Byte (see Figures 12–15)) to program output voltage and
warning/faults thresholds, read monitored data, and pro-
vide access to all manufacturer-specific commands.
Figure 12. SMBus Protocols
WRITE BYTE FORMAT
READ BYTE FORMAT
WRITE WORD FORMAT
READ WORD FORMAT
SEND BYTE FORMAT
S
S
S
S
S
SLAVE ADDRESS
SLAVE ADDRESS
SLAVE ADDRESS
SLAVE ADDRESS
SLAVE ADDRESS
7 BITS
7 BITS
7 BITS
7 BITS
7 BITS
ADDR
ADDR
ADDR
ADDR
ADDR
______________________________________________________________________________________
Digital Power-Supply Controller/Monitor
W
W
W
W
W
PMBus Digital Interface
A
A
A
A
A
COMMAND BYTE:
SELECTS WHICH
COMMAND PARAMETER
TO WRITE TO
COMMAND BYTE:
SELECTS WHICH
COMMAND PARAMETER
TO READ FROM
COMMAND BYTE:
SELECTS WHICH
COMMAND PARAMETER
TO WRITE TO
COMMAND BYTE:
SELECTS WHICH
COMMAND PARAMETER
TO READ FROM
COMMAND BYTE: SEND
COMMAND WITH NO DATA
COMMAND
COMMAND
COMMAND
COMMAND
COMMAND
8 BITS
8 BITS
8 BITS
8 BITS
8 BITS
A
A
A
A
A
DATA BYTE: DATA FOR THE COMMAND
SET BY THE COMMAND BYTE
DATA BYTE: DATA FOR THE COMMAND SET BY THE
COMMAND BYTE
SR
SR
P
DATA0
8 BITS
8 BITS
SLAVE ADDRESS:
REPEATED DUE TO
CHANGE IN DATA-FLOW
DIRECTION
SLAVE ADDRESS:
REPEATED DUE TO
CHANGE IN DATA-FLOW
DIRECTION
DATA
7 BITS
7 BITS
ADDR
ADDR
The MAX8688 also supports the group command. The
group command is used to send commands to more
than one PMBus device. It is not required that all the
devices receive the same command. However, no more
than one command can be sent to any one device in
one group command packet. The group command
must not be used with commands that require receiving
devices to respond with data, such as the
STATUS_BYTE command. When the MAX8688 receives
a command through this protocol, it immediately begins
execution of the received command after detecting the
STOP condition.
When the data word is transmitted, the lower order byte
is sent first and the higher order byte is sent last. Within
any byte, the most significant bit (MSB) is sent first and
the least significant bit (LSB) is sent last.
A
A
with PMBus Interface
P
R
R
DATA1
8 BITS
A
A
DATA BYTE: DATA FOR THE COMMAND
SET BY THE COMMAND BYTE
DATA BYTE: DATA FOR THE COMMAND SET BY THE
COMMAND BYTE
S
SR = REPEATED START CONDITION.
P
DATA0
8 BITS
8 BITS
DATA
= START CONDITION.
= STOP CONDITION.
= SLAVE TRANSMISSION.
A
P
NA
A
P
DATA1
8 BITS
NA
P
21

Related parts for MAX8688ALETG+