ADN8831ACPZ-REEL7 Analog Devices Inc, ADN8831ACPZ-REEL7 Datasheet

IC THERMO COOLER CTRLR 32LFCSP

ADN8831ACPZ-REEL7

Manufacturer Part Number
ADN8831ACPZ-REEL7
Description
IC THERMO COOLER CTRLR 32LFCSP
Manufacturer
Analog Devices Inc
Datasheet

Specifications of ADN8831ACPZ-REEL7

Applications
Thermoelectric Cooler
Current - Supply
8mA
Voltage - Supply
3 V ~ 5.5 V
Operating Temperature
-40°C ~ 85°C
Mounting Type
Surface Mount
Package / Case
32-LFCSP
Ic Function
Thermoelectric Cooler Controller
Supply Voltage Range
3V To 5.5V
Operating Temperature Range
-40°C To +85°C
Digital Ic Case Style
LFCSP
No. Of Pins
32
Msl
MSL 1 - Unlimited
Lead Free Status / RoHS Status
Lead free / RoHS Compliant
Other names
ADN8831ACPZ-REEL7TR

Available stocks

Company
Part Number
Manufacturer
Quantity
Price
Part Number:
ADN8831ACPZ-REEL7
Manufacturer:
ADI/亚德诺
Quantity:
20 000
1
PCN #: 06_0050
Title:
ADN8831 Product Redesign and Datasheet Change
Date Published:
May 25, 2006
Type:
Device
Part Number:
ADN8831
Proposed Change:
Reason for Change:
Summary of Supporting Information:
Full characterization was performed and the device now meets datasheet requirements. The new silicon will replace the old silicon.
Planned Date Change Effective:
September 13, 2006
Contact:
Sumit Awasthi
Product Marketing Engineer
Phone: 781-937-1567
Fax: 781-937-1038
Email: sumit.awasthi@analog.com
Analog Devices, Inc.
Redesign the circuit to:
1. Create a single threshold point for changing the TEC bias level. The old design had two threshold levels occuring
at VDD equal to 3.5V and 4.5V. The new design has a single threshold level occuring at VDD equal to 4.0V.
2. Remove the fault protection mode. This mode of operation has been removed from the product.
1. It was found that on some designs and layouts, the device would transition the TEC bias point during a start up or
transient condition when VDD momentarily dipped below the threshold voltage. By eliminating the second
threshold point and shifting the new single threshold from 4.5V to 4.0V, this problem has been eliminated.
2. It was also found on some designs that if the TEC bias point shifted as VDD changed, the part could erroneously
enter into a fault mode and not recover. By removing the fault detection, this problem has been eliminated.
-- ADI Confidential --
PCN

Related parts for ADN8831ACPZ-REEL7

Related keywords