MAX17075ETG+ Maxim Integrated Products, MAX17075ETG+ Datasheet - Page 15

IC DC-DC CONV W/CHRG PUMP 24TQFN

MAX17075ETG+

Manufacturer Part Number
MAX17075ETG+
Description
IC DC-DC CONV W/CHRG PUMP 24TQFN
Manufacturer
Maxim Integrated Products
Datasheet

Specifications of MAX17075ETG+

Applications
LCD TV/Monitor
Current - Supply
4mA
Voltage - Supply
2.3 V ~ 5.5 V
Operating Temperature
-40°C ~ 85°C
Mounting Type
Surface Mount
Package / Case
24-TQFN Exposed Pad
Lead Free Status / RoHS Status
Lead free / RoHS Compliant
The negative charge-pump regulator is typically used to
generate the negative supply rail for the TFT LCD gate
driver ICs. The output voltage is set with an external
resistive voltage-divider from its output to REF with the
midpoint connected to FBN. The number of charge-
pump stages and the setting of the feedback divider
determine the output of the negative charge-pump regu-
lator. The charge-pump controller includes a high-side p-
channel MOSFET (P2) and a low-side n-channel MOSFET
(N2) to control the power transfer as shown in Figure 5.
The error amplifier compares the feedback signal (FBN)
with a 250mV internal reference. If the feedback signal
is above the reference, the charge-pump regulator
turns on N2 and turns off P2 when the rising edge of the
oscillator clock arrives, level shifting C11. This connects
C11 in parallel with reservoir capacitor C10. If the volt-
age across C10 minus a diode drop (V
higher than the level-shifted flying capacitor voltage
(-V
Figure 5. Negative Charge-Pump Regulator Block Diagram
Boost Regulator with Integrated Charge Pumps,
C11
), charge flows from C10 to C11 until diode D4-2
Negative Charge-Pump Regulator
Switch Control, and High-Current Op Amp
______________________________________________________________________________________
0.25V
REF
MAX17075
NEGATIVE CHARGE-PUMP REGULATOR
AMPLIFIER
ERROR
OSC
C10
- V
DIODE
) is
turns off. The falling edge of the oscillator clock turns
off N2 and turns on P2, allowing V
ing capacitor C11 through diode D4-1. If the feedback
signal is below the reference when the rising edge of
the oscillator comes, the regulator ignores this clock
edge and keeps P2 on and N2 off.
The MAX17075 also monitors the FBN voltage for
undervoltage conditions. If the V
below 80% of the nominal regulation voltage (V
V
fault latch, shutting down all outputs except REF. Once
the fault condition is removed, cycle the input voltage
(below the UVLO falling threshold) to clear the fault
latch and reactivate the device.
The MAX17075 has one operational amplifier. The oper-
ational amplifier is typically used to drive the LCD back-
plane (VCOM) or the gamma-correction divider string. It
features ±500mA output short-circuit current, 45V/µs
slew rate, and 20MHz, 3dB bandwidth.
FBN
P2
N2
DRVN
) for approximately 50ms, the MAX17075 sets a
SUP
FBN
SUPPLY
INPUT
C11
D4-1
D4-2
R7
Operational Amplifiers
R6
C10
SUP
FBN
GOFF
REF
to charge up fly-
is continuously
REF
15
-