TC647VPA Microchip Technology, TC647VPA Datasheet - Page 7

no-image

TC647VPA

Manufacturer Part Number
TC647VPA
Description
IC PWM FAN SPEED CTRLR 8-DIP
Manufacturer
Microchip Technology
Type
Controller - PWM Fanr
Datasheet

Specifications of TC647VPA

Applications
Fan Controller, Brushless (BLDC)
Number Of Outputs
1
Voltage - Supply
3 V ~ 5.5 V
Operating Temperature
0°C ~ 85°C
Mounting Type
Through Hole
Package / Case
8-DIP (0.300", 7.62mm)
Motor Type
DC Brushless
No. Of Outputs
1
Output Current
5mA
Supply Voltage Range
3V To 5.5V
Driver Case Style
DIP
No. Of Pins
8
Operating Temperature Range
0°C To +85°C
Product
Fan / Motor Controllers / Drivers
Operating Supply Voltage
3 V to 5.5 V
Supply Current
1 mA
Mounting Style
Through Hole
Lead Free Status / RoHS Status
Lead free / RoHS Compliant
Current - Output
-
Voltage - Load
-
Lead Free Status / Rohs Status
Lead free / RoHS Compliant

Available stocks

Company
Part Number
Manufacturer
Quantity
Price
Part Number:
TC647VPA
Manufacturer:
MICROCHIP
Quantity:
12 000
4.0
The flowcharts describing the TC647’s behavioral
algorithm are shown in Figure 4-1. They can be
summarized as follows:
4.1
(1) Assuming the device is not being held in shutdown
(2) Turn V
(3) During this Start-up Timer, if a fan pulse is
(4) Activate the 32-cycle Start-up Timer one more time
(5) Proceed to Fan Fault.
(6) End.
4.2
Normal Operation is an endless loop which may only
be exited by entering shutdown mode or Fan Fault. The
loop can be thought of as executing at the frequency of
the oscillator and PWM.
(1) Reset the missing pulse detector.
(2) Is TC647 in shutdown? If so…
(3) Drive V
(4) If a fan pulse is detected, branch back to the start
(5) If the missing pulse detector times out …
(6) Activate the 3-cycle Diagnostic Timer and look for
(7) Activate the 32-cycle Start-up Timer and look for
(8) Quit Normal Operation and go to Fan Fault.
(9) End.
2002 Microchip Technology Inc.
of the loop (1).
pulses; if a fan pulse is detected, branch back to
the start of the loop (1); if none are received…
c. Exit the loop and wait for V
of V
mode (V
clock. This ensures that the fan will start from a
dead stop.
detected, branch to Normal Operation; if none are
received…
and look for fan pulse; if a fan pulse is detected,
proceed to Normal Operation; if none are
received…
pulses; if a fan pulse is detected, branch back to
the start of the loop (1); if none are received…
a. V
b. FAULT is disabled.
operation (indistinguishable from Power-up).
IN
OUT
SYSTEM BEHAVIOR
Power-Up
Normal Operation
and V
OUT
OUT
MIN
duty cycle goes to zero.
output on for 32 cycles of the PWM
to a duty cycle proportional to greater
MIN
> V
REL
on a cycle by cycle basis.
)…
MIN
> V
REL
to resume
4.3
Fan Fault is an infinite loop wherein the TC647 is
latched in shutdown mode. This mode can only be
released by a reset (i.e., V
V
(1) While in this state, FAULT is latched on (low) and
(2) A reset sequence applied to the V
(3) End.
SHDN
the V
the loop to Power-up.
, then above V
Fan Fault
OUT
output is disabled.
REL
, or by power cycling).
MIN
being brought below
DS21447C-page 7
TC647
MIN
pin will exit

Related parts for TC647VPA