LDP10EI10-A Panduit Corp, LDP10EI10-A Datasheet - Page 135

no-image

LDP10EI10-A

Manufacturer Part Number
LDP10EI10-A
Description
RACEWAY 1CHAN LG AD IVR(10=10')
Manufacturer
Panduit Corp
Series
Pan-Way™r
Datasheet

Specifications of LDP10EI10-A

Wire Duct Type
Solid (Raceway), Single Channel
Height
0.860" (21.80mm)
Length
10.00' (3.05m)
Width
1.51" (38.4mm)
Mounting Type
Adhesive
Features
Attached Latching Lid
Color
Ivory
P
Twin-70 non-metallic, multi-channel surface raceway shall be used to route, protect, and conceal data, voice, fiber optic, and
power cabling. The raceway shall be listed as suitable for use in applications up to 600 volts between conductors by
Underwriters Laboratories, Inc. per standard 5A, and by Canadian Standards Association, Inc. per 22.2 no. 62.1-03, when
screw secured and installed per instructions. A full complement of fittings with a 1" minimum bend radius compliant with
TIA/EIA-568-B, must be available as well as device brackets and internal junction boxes to install a variety of communication
and electrical devices. The raceway shall provide two separate covers to maintain total separation of power and low voltage
cabling. PANDUIT
resistant yet also allow access for moves, adds, and changes. Twin-70 shall be manufactured from impact-resistant material
with flammability rating of V-0. Twin-70 raceway finish shall be pure of color and will resist scratches and dents, and will not
peel or corrode. Twin-70 raceway shall be available in three standard colors and shall be optimized for use with the
PANDUIT
P
T-45 non-metallic multi-channel, two-piece, hinged cover design surface raceway shall be used to route, protect, and conceal
data, voice, video, fiber optic and power cabling. The raceway shall be listed as suitable for use in applications up to 600
volts between conductors by Underwriters Laboratories, Inc. per standard 5A, and by Canadian Standards Association, Inc.
per 22.2 no. 62.1-03, when screw secured and installed per instructions. A full complement of fittings with a 1" minimum
bend radius compliant with TIA/EIA-568-B, must be available as well as device brackets and junction boxes to install a
variety of communication and electrical devices. Divider walls must be available to form separate channels in the
multi-channel raceway. An offset box shall be available, with versions for “snap-on” as well as “screw mount” faceplates, for
mounting the power receptacle or the data receptacles outside of the raceway channel. T-45 raceway will be manufactured
from impact-resistant material with flammability rating of V-0. T-45 raceway must be tamper resistant yet also allow access for
moves, adds and changes. T-45 raceway finish shall be pure color and will resist scratches and dents and will not peel or
corrode. T-45 raceway shall be available in two standard colors and shall be optimized for use with the PANDUIT
Communication System.
P
LD2P10 non-metallic, two channel, one-piece tamper resistant latch design, adhesive backed, hinged cover, surface raceway
shall be used to route, protect, and conceal data, voice, fiber optic, and power cabling. The raceway shall be listed as
suitable for use in applications up to 600 volts between conductors by Underwriters Laboratories, Inc. per standard 5A, and
by Canadian Standards Association, Inc. per 22.2 no. 62.1-03, when screw secured and installed per instructions. The
raceway will include a full complement of fittings, which maintain a 1" minimum bend radius, compliant with TIA/EIA-568-B,
as well as junction boxes, which allow termination of both power and communications cabling. LD2P10 raceway will be
manufactured from impact-resistant material with flammability rating of V-0. LD2P10 raceway finish shall be pure color and
will resist scratches and dents, and will not peel or corrode. LD2P10 raceway shall be available in four standard colors, and
shall be optimized for use with the PANDUIT
P
LDP non-metallic single channel, one-piece tamper resistant latch design, adhesive backed, hinged cover, surface raceway,
shall be used to route, protect and conceal data, voice, video, fiber optic or power cabling. The raceway shall be listed as
suitable for use in applications up to 600 volts between conductors by Underwriters Laboratories, Inc. per standard 5A, when
screw secured and installed per instructions. The raceway will include a full complement of power, bend radius control
(BRC), and standard fittings consisting of, but not limited to: elbows (internal and external), couplings for joining raceway
sections, blank end fittings for closing open ends of the raceway, entrance fittings, reducer fittings, tee fittings, and an
optional raceway installation tool. The BRC fittings shall incorporate a minimum 1" bend radius as recommended for
Category 5e & 6 UTP and fiber optic cabling in TIA/EIA-568-B. LDP surface raceway will be manufactured in two different
lengths from impact-resistant material with flammability rating of V-0. LDP raceway finish shall be pure color and will resist
scratches and dents and will not peel or corrode. LDP raceway shall be available in three sizes, four standard colors and
shall be optimized for use with the PANDUIT
AN
AN
AN
AN
-W
-W
-W
-W
AY
AY
AY
AY
®
®
®
®
®
P
Twin-70 Surface Raceway
T-45 Surface Raceway
LD2P10 Surface Raceway
LDP Surface Raceway
AN
-N
ET
®
“snap-on” faceplates for data and power terminations shall be available. Twin-70 raceway must be tamper
®
Communication System.
®
®
For service and technical support, call 800-777-3300 (outside the U.S. and Canada, see back cover).
P
P
AN
AN
-N
-N
ET
ET
®
®
Communication System.
Communication System.
®
P
AN
-N
ET
®
N7
Faceplates,
Furniture
LD Profile
Overview
Selection
Technical
Ultimate
Labeling
Twin-70
Boxes &
Glossary
System
System
Office
Outlet
Quick
Guide
TG-70
Index
Cove
T130
T-70
T-45
Pole
Info
ID
&
&