LTC4260IGN#PBF Linear Technology, LTC4260IGN#PBF Datasheet - Page 22

IC CTLR HOT SWAP I2C 24-SSOP

LTC4260IGN#PBF

Manufacturer Part Number
LTC4260IGN#PBF
Description
IC CTLR HOT SWAP I2C 24-SSOP
Manufacturer
Linear Technology
Type
Hot-Swap Controllerr
Datasheet

Specifications of LTC4260IGN#PBF

Applications
General Purpose
Internal Switch(s)
No
Voltage - Supply
8.5 V ~ 80 V
Operating Temperature
-40°C ~ 85°C
Mounting Type
Surface Mount
Package / Case
24-SSOP (0.150", 3.90mm Width)
Family Name
LTC4260
Package Type
SSOP N
Operating Supply Voltage (min)
8.5V
Operating Supply Voltage (max)
80V
Operating Temperature (min)
-40C
Operating Temperature (max)
85C
Operating Temperature Classification
Industrial
Product Depth (mm)
3.99mm
Product Height (mm)
1.5mm
Mounting
Surface Mount
Pin Count
24
Lead Free Status / RoHS Status
Lead free / RoHS Compliant

Available stocks

Company
Part Number
Manufacturer
Quantity
Price
Company:
Part Number:
LTC4260IGN#PBF
Manufacturer:
LT
Quantity:
3 605
Company:
Part Number:
LTC4260IGN#PBF
Manufacturer:
LT/凌特
Quantity:
20 000
APPLICATIO S I FOR ATIO
LTC4260
Table 4. ALERT Register B (01h)—Read/Write
BIT
B7
B6
B5
B4
B3
B2
B1
B0
Table 5. STATUS Register C (02h)—Read Only
BIT
C7
C6
C5
C4
C3
C2
C1
C0
22
NAME
Reserved
GPIO Output
FET Short Alert
BD_PRST State Change Alert
Power Bad Alert
Overcurrent Alert
Undervoltage Alert
Overvoltage Alert
NAME
FET On
GPIO Input
FET Short Present
Board Present
Power Bad
Overcurrent
Undervoltage
Overvoltage
U
U
W
OPERATION
Not Used
Output Data Bit to GPIO Pin When Configured as Output. Defaults to 0
Enables Alert for FET Short Condition
1 = Enable Alert, 0 = Disable Alert (Default)
Enables Alert When BD_PRST Changes State
1 = Enable Alert, 0 = Disable Alert (Default)
Enables Alert when Output Power is Bad
1 = Enable Alert, 0 = Disable Alert (Default)
Enables Alert for Overcurrent Condition
1 = Enable Alert, 0 = Disable Alert (Default)
Enables Alert for Undervoltage Condition
1 = Enable Alert, 0 = Disable Alert (Default)
Enables Alert for Overvoltage Condition
1 = Enable Alert, 0 = Disable Alert (Default)
OPERATION
Indicates State of FET
1 = FET On, 0 = FET Off
State of the GPIO Pin
1 = GPIO High, 0 = GPIO Low
Indicates Potential FET Short if Current Sense Voltage Exceeds 2mV While FET is Off
1 = FET is Shorted, 0 = FET is Not Shorted
Indicates if a Board is Present When BD_PRST is Low
1 = BD_PRST Pin Low, 0 = BD_PRST Pin High
Indicates Power is Bad When FB is Low
1 = FB Low, 0 = FB High
Indicates Overcurrent Condition During Cool Down Cycle
1 = Overcurrent, 0 = Not Overcurrent
Indicates Input Undervoltage When UV is Low
1 = UV Low, 0 = UV High
Indicates Input Overvoltage When OV is High
1 = OV High, 0 = OV Low
U
4260fa

Related parts for LTC4260IGN#PBF