MAX5922BEUI+ Maxim Integrated Products, MAX5922BEUI+ Datasheet - Page 15

IC NETWORK PWR SW +48V 28-TSSOP

MAX5922BEUI+

Manufacturer Part Number
MAX5922BEUI+
Description
IC NETWORK PWR SW +48V 28-TSSOP
Manufacturer
Maxim Integrated Products
Type
Power over Ethernet Switch (PoE)r
Datasheet

Specifications of MAX5922BEUI+

Applications
Remote Peripherals (Industrial Controls, Cameras, Data Access)
Internal Switch(s)
Yes
Voltage - Supply
32 V ~ 60 V
Operating Temperature
-40°C ~ 85°C
Mounting Type
Surface Mount
Package / Case
28-TSSOP
On Resistance (max)
0.45 Ohms
Maximum Operating Temperature
+ 85 C
Minimum Operating Temperature
- 40 C
Mounting Style
SMD/SMT
Lead Free Status / RoHS Status
Lead free / RoHS Compliant
Following a valid PD detection, and if the CLASS pin is
high, the MAX5922 enters the PD classification mode. If
the CLASS pin is low, the PD classification mode is
skipped and the MAX5922 goes directly from PD
detection to the power mode. During the PD classifica-
tion mode, the MAX5922 forces a probe voltage (17.5V)
at the OUT pin and measures the current out of this pin.
The measured current determines the class of the PD.
The classification results are reported at the classifica-
tion logic outputs CL0, CL1, CL2. Table 2 shows the
classification threshold limits and the corresponding
logic outputs CL0, CL1, and CL2.
Figure 5. PD Detection with an Invalid PD Signature
Table 2. PD Classification Threshold Limits
0.5 to 4 or above 43
9 to 12
17 to 20
26 to 30
36 to 42
N/A
N/A
Power device not detected yet
or CLASS pin connected low.
SENSED CURRENT (mA)
V
OUT
V
IN
UVLO
+48V, Single-Port Network Power Switch
4V
8V
______________________________________________________________________________________
0V
PD Classification Mode
(PD Classification)
t
DET1
88ms
CL2
0
0
0
0
1
1
1
1
=
t
DET2
88ms
CL1
=
0
0
1
1
0
0
1
1
CL0
0
1
0
1
0
1
0
1
Class 0
Class 1
Class 2
Class 3
Class 4
Not used
Successful detection (classification disabled or DET_DIS = low)
Detection ongoing
Connect an external 150Ω ±1% resistor (R
RCL to IN to set the classification current reference. If
the PD classification function is not used, RCL can be
left floating. For the MAX5922B/MAX5922C, the
DET_DIS pin must be connected low to enable the
classification phase. If DET_DIS is connected high, the
classification phase is disabled regardless of the state
of the CLASS pin. After the classification phase, the
MAX5922 enters power-up.
After the PD is successfully detected and classified, the
MAX5922 enters power-up mode. During this mode,
the MAX5922 gradually turns on the integrated N-chan-
nel MOSFET. To minimize EMI, the MAX5922 limits the
For Power-Over-LAN
CLASS TYPES
Power-Up Mode
t
RCL
) from
15

Related parts for MAX5922BEUI+