MCP3909-I/SS Microchip Technology, MCP3909-I/SS Datasheet - Page 14

IC POWER METERING-1 PHASE 24SSOP

MCP3909-I/SS

Manufacturer Part Number
MCP3909-I/SS
Description
IC POWER METERING-1 PHASE 24SSOP
Manufacturer
Microchip Technology
Datasheets

Specifications of MCP3909-I/SS

Package / Case
24-SSOP (0.200", 5.30mm Width)
Input Impedance
390 KOhm
Measurement Error
0.1%
Voltage - I/o High
2.4V
Voltage - I/o Low
0.85V
Current - Supply
2.3mA
Voltage - Supply
4.5 V ~ 5.5 V
Operating Temperature
-40°C ~ 85°C
Mounting Type
Surface Mount
Meter Type
Single Phase
Operating Temperature Range
- 40 C to + 85 C
Mounting Style
SMD/SMT
Supply Voltage Range
4.5V To 5.5V
Digital Ic Case Style
SSOP
No. Of Pins
24
Interface Type
Serial, SPI
Supply Voltage Max
5.5V
Rohs Compliant
Yes
Lead Free Status / RoHS Status
Lead free / RoHS Compliant
For Use With
MCP3909EV-MCU16 - EVALUATION BOARD FOR MCP3909MCP3909RD-3PH1 - REF DESIGN MCP3909 3PH ENGY MTR
Lead Free Status / Rohs Status
Lead free / RoHS Compliant

Available stocks

Company
Part Number
Manufacturer
Quantity
Price
Part Number:
MCP3909-I/SS
Manufacturer:
MICROCHIP/微芯
Quantity:
20 000
MCP3909 / dsPIC33F 3-Phase Energy Meter Reference Design
DS51723A-page 14
Step 1: Connect the meter to 220V line and load
The diagram below shows where the voltage and current connections should be made.
It is not required to connect all 3 phases for the meter to be operational.
220VAC should be placed between either V
The AC load for a given phase should then be connected to the I
phase.
FIGURE 1-2:
Step 2: Turn On Line/Load Power to the Meter
Turn on the power to the energy meter. D1 should be lit showing the meter has power.
At this point, if a load is connected and the meter is measuring power, the power LED,
D1, should be blinking.
IA
IN
VA
Meter Case Bottom.
IA
OUT
IB
IN
VB
IB
A
, V
OUT
B
, V
C
IC
and N
IN
VC
© 2009 Microchip Technology Inc.
IN
, N
IC
IN
OUT
OUT
and I
.
OUT
of a given

Related parts for MCP3909-I/SS