MCP73223T-C2SI/MF Microchip Technology, MCP73223T-C2SI/MF Datasheet - Page 5

IC LI IRON PHOSPHATE CTRLR 10DFN

MCP73223T-C2SI/MF

Manufacturer Part Number
MCP73223T-C2SI/MF
Description
IC LI IRON PHOSPHATE CTRLR 10DFN
Manufacturer
Microchip Technology
Datasheet

Specifications of MCP73223T-C2SI/MF

Battery Type
Lithium Iron Phosphate (LiFePO4)
Package / Case
10-DFN
Function
Charge Management
Voltage - Supply
4 V ~ 16 V
Operating Temperature
-40°C ~ 85°C
Mounting Type
Surface Mount
Product
Charge Management
Output Voltage
7.2 V
Output Current
130 mA to 1100 mA
Operating Supply Voltage
4.2 V to 13 V
Supply Current
700 uA
Maximum Operating Temperature
+ 85 C
Minimum Operating Temperature
- 40 C
Charge Safety Timers
No
Mounting Style
SMD/SMT
Temperature Monitoring
No
Uvlo Start Threshold
4.15 V
Uvlo Stop Threshold
4.05 V
Lead Free Status / RoHS Status
Lead free / RoHS Compliant
For Use With
MCP73X23EV-LFP - BOARD EVAL BATT CHARGER MCP73X23
Lead Free Status / Rohs Status
Lead free / RoHS Compliant

Available stocks

Company
Part Number
Manufacturer
Quantity
Price
Part Number:
MCP73223T-C2SI/MF
Manufacturer:
MICROCHIP
Quantity:
12 000
1.0
Absolute Maximum Ratings†
V
V
All Inputs and Outputs w.r.t. V
Maximum Junction Temperature, T
Storage temperature .....................................-65°C to +150°C
ESD protection on all pins
Human Body Model (1.5 k in Series with 100 pF)4 kV
Machine Model (200pF, No Series Resistance) ..............300V
DC CHARACTERISTICS
 2011 Microchip Technology Inc.
Electrical Specifications: Unless otherwise indicated, all limits apply for V
T
Supply Input
Input Voltage Range
Operating Supply Voltage
Operating Supply Voltage
Supply Current
Battery Discharge Current
Output Reverse Leakage
Current
Undervoltage Lockout
UVLO Start Threshold
UVLO Stop Threshold
UVLO Hysteresis
Overvoltage Protection
OVP Start Threshold
OVP Start Threshold
OVP Hysteresis
Voltage Regulation (Constant Voltage Mode)
Regulated Output Voltage
Output Voltage Tolerance
Regulated Output Voltage
Output Voltage Tolerance
Line Regulation
Load Regulation
Note 1:
DD
PROG
A
= -40°C to +85°C. Typical values are at +25°C, V
................................................................................18.0V
..............................................................................6.0V
Parameters
ELECTRICAL
CHARACTERISTICS
Not production tested. Ensured by design.
SS
V
V
I
DISCHARGE
............... -0.3 to (V
BAT
V
V
V
V
OVPHYS
V
V
BAT
V
V
V
V
V
Sym
J
V
V
V
START
STOP
I
RTOL
RTOL
OVP
OVP
REG
REG
)/V
HYS
............ Internally Limited
SS
DD
DD
DD
BAT
/V
BAT
DD
/
|
|
3.582
7.157
4.10
4.00
12.8
Min
-0.5
-0.6
4.2
4.2
6.4
4
DD
DD
+0.3)V
= [V
REG
4.15
4.05
3.60
7.20
0.05
0.05
(Typical) + 1.0V]
Typ
700
100
150
0.5
0.5
6.5
30
50
13
4
6
† Notice: Stresses above those listed under “Maximum
Ratings” may cause permanent damage to the device. This is
a stress rating only and functional operation of the device at
those or any other conditions above those indicated in the
operational listings of this specification is not implied.
Exposure to maximum rating conditions for extended periods
may affect device reliability.
DD
= [V
3.618
7.243
1500
Max
13.0
4.25
4.15
13.2
+0.5
+0.6
0.20
0.20
100
150
6.5
5.5
6.6
16
17
2
2
REG
(Typical) + 0.3V] to 12V,
MCP73123/223
Units
%/V
mV
mV
µA
µA
µA
µA
µA
µA
µA
%
%
%
V
V
V
V
V
V
V
V
V
MCP73123
MCP73223
Shutdown (V
Charging
Standby (PROG Floating)
Charge Complete; No Battery;
V
Standby (PROG Floating)
Shutdown (V
or V
Charge Complete; V
MCP73123
MCP73223
T
- MCP73123
T
T
- MCP73123
T
V
- MCP73123
V
- MCP73223
I
I
V
OUT
OUT
A
A
A
A
DD
DD
DD
DD
= -5°C to +55°C, I
= -5°C to +55°C
= -5°C to +55°C, I
= -5°C to +55°C
DD
 V
= [V
= [V
= [V
= 50 mA
= 50 mA - 150 mA
 V
STOP
REG
REG
REG
STOP
Conditions
(Typical)+1V] to 6V
(Typical)+1V] to 12V
(Typical)+1V]
DD
DD
)
DS22191C-page 5
 V
 V
BAT
BAT
OUT
OUT
DD
,
- 150 mV)
is present
= 50 mA
= 50 mA

Related parts for MCP73223T-C2SI/MF