DS2784G+ Maxim Integrated Products, DS2784G+ Datasheet - Page 35

IC FUEL GAUGE STND-ALONE 14-TDFN

DS2784G+

Manufacturer Part Number
DS2784G+
Description
IC FUEL GAUGE STND-ALONE 14-TDFN
Manufacturer
Maxim Integrated Products
Datasheet

Specifications of DS2784G+

Function
Fuel, Gas Gauge/Monitor
Battery Type
Lithium-Ion (Li-Ion), Lithium-Polymer (Li-Pol)
Voltage - Supply
2.5 V ~ 4.6 V
Operating Temperature
-40°C ~ 85°C
Mounting Type
Surface Mount
Package / Case
14-TDFN
Product
Fuel Gauges
Operating Supply Voltage
2.5 V to 4.6 V
Supply Current
85 uA
Maximum Operating Temperature
+ 85 C
Minimum Operating Temperature
- 40 C
Charge Safety Timers
Yes
Mounting Style
SMD/SMT
Temperature Monitoring
Yes
Uvlo Start Threshold
2.4 V
Uvlo Stop Threshold
2.5 V
Lead Free Status / RoHS Status
Lead free / RoHS Compliant
The 1-Wire bus must have a pullup resistor at the bus-master end of the bus. A value of between 2k and 5k is
recommended. The idle state for the 1-Wire bus is high. If, for any reason, a bus transaction must be suspended,
the bus must be left in the idle state to properly resume the transaction later. Note that if the bus is left low for more
than t
transaction.
Figure 9. 1-Wire Bus Interface Circuitry
TRANSACTION SEQUENCE
The protocol for accessing the DS2784 through the 1-Wire port is as follows:
All transactions of the 1-Wire bus begin with an initialization sequence consisting of a reset pulse transmitted by the
bus master, followed by a presence pulse simultaneously transmitted by the DS2784 and any other slaves on the
bus. The presence pulse tells the bus master that one or more devices are on the bus and ready to operate. For
more details, see the Net Address Commands section.
NET ADDRESS COMMANDS
Once the bus master has detected the presence of one or more slaves, it can issue one of the net address
commands described in the following paragraphs. The name of each net address command (ROM command) is
followed by the 8-bit op code for that command in square brackets.
Read Net Address [33h]. This command allows the bus master to read the DS2784’s 1-Wire net address. This
command can only be used if there is a single slave on the bus. If more than one slave is present, a data collision
occurs when all slaves try to transmit at the same time (open drain produces a wired-AND result).
Match Net Address [55h]. This command allows the bus master to specifically address one DS2784 on the 1-Wire
bus. Only the addressed DS2784 responds to any subsequent function command. All other slave devices ignore
the function command and wait for a reset pulse. This command can be used with one or more slave devices on
the bus.
Skip Net Address [CCh]. This command saves time when there is only one DS2784 on the bus by allowing the
bus master to issue a function command without specifying the address of the slave. If more than one slave device
is present on the bus, a subsequent function command can cause a data collision when all slaves transmit data at
the same time.
LOW0
Initialization
Net Address Command
Function Command(s)
Data Transfer (not all commands have data transfer)
, slave devices on the bus begin to interpret the low period as a reset pulse, effectively terminating the
35 of 43

Related parts for DS2784G+