DS2781G+ Maxim Integrated Products, DS2781G+ Datasheet - Page 24

IC FUEL GAUGE STND ALONE 10-TDFN

DS2781G+

Manufacturer Part Number
DS2781G+
Description
IC FUEL GAUGE STND ALONE 10-TDFN
Manufacturer
Maxim Integrated Products
Datasheet

Specifications of DS2781G+

Function
Fuel, Gas Gauge/Monitor
Battery Type
Lithium-Ion (Li-Ion), Lithium-Polymer (Li-Pol)
Voltage - Supply
2.5 V ~ 10 V
Operating Temperature
-40°C ~ 85°C
Mounting Type
Surface Mount
Package / Case
10-TDFN Exposed Pad
Operating Supply Voltage
2.5 V to 10 V
Supply Current
70 uA
Maximum Operating Temperature
+ 85 C
Minimum Operating Temperature
- 40 C
Charge Safety Timers
No
Mounting Style
SMD/SMT
Temperature Monitoring
Yes
Lead Free Status / RoHS Status
Lead free / RoHS Compliant
In the circuit in Figure 23, the shift register bits are initialized to 0. Then, starting with the least significant bit of the
family code, one bit at a time is shifted in. After the 8th bit of the family code has been entered, then the serial
number is entered. After the 48th bit of the serial number has been entered, the shift register contains the CRC
value.
Figure 23. 1-Wire CRC Generation Block Diagram
HARDWARE CONFIGURATION
Because the 1-Wire bus has only a single line, it is important that each device on the bus be able to drive it at the
appropriate time. To facilitate this, each device attached to the 1-Wire bus must connect to the bus with open-drain
or tri-state output drivers. The DS2781 uses an open-drain output driver as part of the bidirectional interface
circuitry shown in Figure 24. If a bidirectional pin is not available on the bus master, separate output and input pins
can be connected together.
The 1-Wire bus must have a pullup resistor at the bus-master end of the bus. For short line lengths, the value of
this resistor should be approximately 5kΩ. The idle state for the 1-Wire bus is high. If, for any reason, a bus
transaction must be suspended, the bus must be left in the idle state to properly resume the transaction later. If the
bus is left low for more than 120μs (16μs for overdrive speed), slave devices on the bus begin to interpret the low
period as a reset pulse, effectively terminating the transaction.
The DS2781 can operate in two communication speed modes, standard and overdrive. The speed mode is
determined by the input logic level of the OVD pin with a logic 0 selecting standard speed and a logic 1 selecting
overdrive speed. The OVD pin must be at a stable logic level of 0 or 1 before initializing a transaction with a reset
pulse. All 1-Wire devices on a multinode bus must operate at the same communication speed for proper operation.
1-Wire timing for both standard and overdrive speeds are listed in the Electrical Characteristics: 1-Wire Interface
tables.
Figure 24. 1-Wire Bus Interface Circuitry
MSb
Rx
Tx
BUS MASTER
Vpullup
(2.0V to 5.5V)
XOR
RX = RECEIVE
TX = TRANSMIT
24 of 31
4.7kΩ
XOR
0.2μA
(typ)
DS2781 1-WIRE PORT
100Ω
MOSFET
LSb
RX
TX
XOR
INPUT

Related parts for DS2781G+