MAX34441EVKIT# Maxim Integrated, MAX34441EVKIT# Datasheet - Page 40

no-image

MAX34441EVKIT#

Manufacturer Part Number
MAX34441EVKIT#
Description
Power Management IC Development Tools MAX34441 Eval Kit
Manufacturer
Maxim Integrated
Type
PWM Controllersr
Series
MAX34441r
Datasheet

Specifications of MAX34441EVKIT#

Rohs
yes
Product
Power Management Development Tools
Tool Is For Evaluation Of
MAX34441
Interface Type
I2C
Maximum Operating Temperature
+ 85 C
Part # Aliases
90-34441#K00
Note_1: All enabled temperature sensor faults are logically ORed together.
Note_2: Temperature and fan faults affect all enabled power supplies. Supplies that are designated as global all respond in the
Note_3: The fault response for a power-supply fault is determined by the programmed fault response for the faulting channel. If
PMBus 5-Channel Power-Supply Manager
and Intelligent Fan Controller
The MFR_VOUT_PEAK command returns the maximum actual measured output voltage. To reset this value to 0, write to this
command with a data value of 0. Any values written to this command are used as a comparison for future peak updates. The
2 data bytes are in DIRECT format.
The MFR_IOUT_PEAK command returns the maximum measured current. To reset this value to 0, write to this com-
mand with a data value of 0. Any values written to this command are used as a comparison for future peak updates.
The 2 data bytes are in DIRECT format.
The MFR_TEMPERATURE_PEAK command returns the maximum measured temperature. To reset this value to its low-
est value, write to this command with a data value of 8000h. Any other values written by this command are used as a
comparison for future peak updates. The 2 data bytes are in DIRECT format.
The MFR_VOUT_MIN command returns the minimum actual measured output voltage. To reset this value, write to this com-
mand with a data value of 7FFFh. Any values written to this command are used as a comparison for future minimum updates.
The 2 data bytes are in DIRECT format.
The MFR_FAULT_RESPONSE command specifies the response to each fault condition supported by the device. In
response to a fault, the device always report the fault in the appropriate status register and asserts the ALERT output
(if enabled in MFR_MODE). A CML fault cannot cause any device action other than setting the status bit and asserting
the ALERT output. The MFR_FAULT_RESPONSE command is described in Table 27.
40
Table_27._MFR_FAULT_RESPONSE
13:12
11:10
BIT_
9:8
7:6
5:4
3:2
1:0
15
14
same manner. This response is the worst-case response of the global channels for the given fault. Supplies that are not
global respond to a temperature or fan fault based upon the programmed response for the particular supply.
this channel is part of a global group, this fault response is performed for all the global channels.
TON_MAX_FAULT_LIMIT_RESPONSE[1:0] See Table 28.
VOUT_OV_FAULT_LIMIT_RESPONSE[1:0] See Table 28.
MFR_FAN_FAULT_LIMIT_RESPONSE[1:0] See Table 28.
VOUT_UV_FAULT_LIMIT_RESPONSE[1:0] See Table 28.
IOUT_OC_FAULT_LIMIT_RESPONSE[1:0] See Table 28.
OT_FAULT_LIMIT_RESPONSE[1:0]
BIT_NAME
GLOBAL
NV_LOG
0
0 = Do not log the fault into MFR_NV_FAULT_LOG.
1 = Log the fault into MFR_NV_FAULT_LOG.
0 = Affect only the selected page power supply.
1 = Affect all supplies with GLOBAL = 1.
These bits always return a 0.
See Table 28 (see Note 1).
MFR_TEMPERATURE_PEAK (D6h)
MEANING
MFR_FAULT_RESPONSE (D9h)
MFR_VOUT_PEAK (D4h)
MFR_IOUT_PEAK (D5h)
MFR_VOUT_MIN (D7h)