KIT 79880-3 Digital View, KIT 79880-3 Datasheet - Page 40

no-image

KIT 79880-3

Manufacturer Part Number
KIT 79880-3
Description
Display Development Tools CONTR KIT SVX-1920 22.5"NL192120AC25-02
Manufacturer
Digital View
Datasheet

Specifications of KIT 79880-3

Product Category
Display Development Tools
Rohs
yes
Specifications subject to change without notice
© Digital View Ltd – Doc Ver 2.2: 12 Dec, 2011 (SVX-1920_manual.doc)
Green level for
selected colour
temperature
Blue level for
selected colour
temperature
Graphic horizontal
resolution enquiry
Graphic vertical
resolution enquiry
Graphic horizontal
sync frequency
enquiry
Graphic vertical
sync frequency
enquiry
OSD status
enquiry
Display Video
Source Select
OSD turn off
Set gamma data
for user defined
gamma curve
“m”
“n”
“i” , ss, c, nn
“o”, ss, c
0xb5,
“m”
“n”
“i” , ss, c, nn
“o”, ss, c
0xb6,
“m”
“n”
“i” , ss, c, nn
“o”, ss, c
0xb7
0xb8
0xb9
0xba
0xbb
0xbc,
“?” |
“0” |
“1”
0xbd
0xbf, mm, c, “?”
0xbf, “R” | “r”
0xbf, mm, c, nn
nn | “+” | “-” |
“r” | “R” |
“?”
nn | “+” | “-” |
“r” | “R” |
“?”
Maximum query *1
Minimum query *1
Set, Source, Temperature
Group, value *1
Query, Source *1
Set the level of the green
channel for the selected colour
temp. =
Reset
Query
Maximum query *1
Minimum query *1
Set, Source, Temperature
Group, value *1
Query, Source *1
Set the level of the blue channel
for the selected colour temp. =
Reset
Query
Maximum query *1
Minimum query *1
Set, Source, Temperature
Group, value *1
Query, Source *1
Horizontal resolution (in pixels)
in 3 digit hex number
Vertical resolution (in lines) in 3
digit hex number
Horizontal sync frequency (in
units of 100Hz) in 3 digit hex
number
Vertical sync frequency (in units
of Hz) in 3 digit hex number and
1 char
Status of OSD
Display Video source select
Query
Name of video source not
displayed.
After switching to a new video
source, the name of the video
source is displayed for 5
seconds.
Turn off the OSD.
Query gamma data for color c
index mm ( c = 0 for color Red,
c=1 for color Green,
c=2 for color Blue)
Set user gamma curve to linear
Set gamma data for color c
value/increment/decrement
value/increment/decrement
c – reference by Color
Temperature
ss - reference by Input main
select(0x98)
Green level for selected colour
temperature
Range : “9””C”-“F””F”
Default : “E””C”
c – reference by Color
Temperature
ss - reference by Input main
select(0x98).
Blue level for selected colour
temperature.
Range : “9””C”-“F””F”
Default : “E””C”
c – reference by Color
Temperature
ss - reference by Input main
select(0x98).
“nnn” = horizontal resolution
“nnn” = vertical resolution
“nnn” = horizontal frequency
“nnnn” = vertical frequency
nnn = 3 digit hex
c= “i” or “p”
interlace or Progressive
0xba added the interlace(i)
or Progressive(p) feedback.
“0” – OSD turned off
“1” – OSD turned on
“2” – Text Overlay on
“3” – Display Mark on
“4” – Screen Marker on
“0” – Disabled.
“1” – Enabled.
“0” – fail.
“1” – successful.
“nn” = gamma data
“1”
“nn” = gamma data
Page
40 of 67

Related parts for KIT 79880-3